82441M Mariner BOLT


82441M BOLT Mariner 7005207, 7005227, 7025200, 7025208CW, 7025500, 7028527, 7030200, 7030205, 7030320, 7040202, 7040206, 7040207, 7040207PW, 7040208, 7040208PW, 7040328, 7040507, 7040706, 7040716, 7048207, 7048227, 7048321, 7055324, 7055524, 7060507, 7060522, 7060528 BOLT

Buy BOLT 82441M Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 22
 

Mariner entire parts catalog list:

7005207 1977
7005227 1977
7025200 1980
7025208CW 1994,1995,1996,1997,1998
7025500 1980
7028527 1977
7030200 1980
7030205 1985,1986,1987,1988,1989,1990
7030320 1980,1990,1992
7040202 1982,1985,1986
7040206 1986,1987,1988,1989
7040207 1977
7040207PW 1989,1990,1991,1992,1993
7040208 1978
7040208PW 1989,1990,1991,1992,1993,1994,1995,1996,1997,1998
7040328 1978,1980
7040507 1987
7040706 1986,1990,1992
7040716 1986
7048207 1977
7048227 1977
7048321 1981
7055324 1984,1985,1988,1989
7055524 1984,1985
7060507 1977
7060522 1982
7060528 1978

Information:


Table 1
Diagnostic Codes Table
CDL Code J1939 Code Code Description Comments
110-3 110-3 Engine Coolant Temperature Sensor : Voltage Above Normal The code is logged if the engine has been running for more than seven minutes. The Electronic Control Module (ECM) uses the last valid engine coolant temperature. If the diagnostic code is active at start-up, the ECM will use intake manifold temperature. When the intake manifold air temperature is not valid, the ECM will default to 90 °C (194 °F) for engine coolant temperature. The ECM will activate the cooling fan after this code has been active for more than eight seconds.
110-4 110-4 Engine Coolant Temperature Sensor : Voltage Below Normal
172-3 N/A Intake Manifold Air Temperature Sensor : Voltage Above Normal The ECM will log the diagnostic code. The ECM will flag the intake manifold air temperature as invalid data. Also, the intake manifold air temperature is set to a default value of 40 °C (104 °F).
172-4 N/A Intake Manifold Air Temperature Sensor : Voltage Below Normal
174-3 174-3 Fuel Temperature Sensor : Voltage Above Normal The code is logged. The ECM will flag the fuel temperature as invalid data and the fuel temperature is set to a default value of 40 °C (104 °F).
174-4 174-4 Fuel Temperature Sensor : Voltage Below Normal
2526-3 172-3 Air Inlet Temperature Sensor : Voltage Above Normal The code is logged.
The ECM detects voltage that is not in the acceptable range.
2526-4 172-4 Air Inlet Temperature Sensor : Voltage Below Normal The code is logged.
The ECM detects voltage that is not in the acceptable range. System OverviewThe sensor signal for the passive sensor is routed from the ECM to terminal 1 of each sensor connector. The sensor return for the passive sensors is routed to the ECM from terminal 2 of each sensor connector.Diagnostics on the Caterpillar Electronic Technician (ET)Wiggle Test - The Wiggle Test allows you to monitor the status of the signals from the sensors.For additional information regarding the Wiggle Test, refer to the documentation that accompanies the Cat ET software.
Illustration 1 g01155187
Terminal locations at the connector for the passive analog sensors
(Terminal 1) Sensor signal
(Terminal 2) Analog sensor return
Illustration 2 g03019119
Table 2
Troubleshooting Test Steps Values Results
1. Check for Diagnostic Trouble Codes
A. Connect to Caterpillar Electronic Technician (ET).
B. Turn the keyswitch to the ON position.
C. Access the "Active Diagnostic Code" screen on Cat ET.
Wait at least 30 seconds in order for the diagnostic codes to become active.
D. Look for these active codes or logged codes:
1. -3
2. -4
Codes
Result: A -3 diagnostic code is active.
Proceed to Test Step 2.
Result: A -4 diagnostic code is active.
Proceed to Test Step 3.
2. Create a Short at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the suspect sensor.
C. Install the jumper wire between terminal 1 (sensor signal) and terminal 2 (sensor return) at the sensor connector.
D. Turn the keyswitch to the ON position.
E. Monitor the diagnostic codes on Cat ET. Check for an active -4 diagnostic code for the suspect sensor.
Wait at least 30 seconds in order for the diagnostic codes to become active.
F. Turn the keyswitch to the OFF position.
Short circuit recognized
Result: The -3 diagnostic code remains active for the suspect sensor.
There is an open in the harness. Repair the wiring or replace the harness.
Verify that the problem is resolved.
Result: A -4 diagnostic code became active after creating the short at the sensor connector.
The wiring is OK. Replace the sensor.
Verify that the problem is resolved.
3. Create an Open at the Suspect Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor connector of the suspect sensor with the active -4 diagnostic code.
C. Turn the keyswitch to the ON position.
D. Monitor the diagnostic codes on Cat ET. Check for an active -3 diagnostic code for the suspect sensor.
Wait at least 30 seconds in order for the diagnostic codes to become active.
E. Turn the keyswitch to the OFF position.
Open circuit recognized
Result: The -4 diagnostic code remains active for the suspect sensor.
There is an open in the harness. Repair the wiring or replace the harness.
Verify that the problem is resolved.
Result: A -3 diagnostic code became active after disconnecting the sensor.
The wiring is OK. Replace the sensor.
Verify that the problem is resolved.
Complete the procedure in the order in which the steps are listed.If the procedure corrected the issue, return the engine to service.If the procedure did not correct the issue, Contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts bolt Mariner:

91686M
 
91686M BOLT
7004201, 7005201, 7005207, 7008204, 7008208, 7008218EW, 7008226, 7008425, 7040202, 7040206, 7040706, 7040716
91710M
 
91710M BOLT
7004201, 7005201, 7005207
14185M
 
14185M BOLT
7004201, 7005201, 7005207
82426M
 
82426M BOLT, BRACKET ATTACHING...
7008238, 7008247, 7015207, 7028207, 7028527, 7048207, 7048227, 7060507, 7060528
82439M
 
82439M BOLT, HOUSING ATTACHING-REAR
7028207, 7028527, 7030200, 7030205, 7040207, 7040208, 7040328, 7040507, 7040706, 7040716, 7048207, 7048227, 7060522
81747M
 
81747M BOLT, CABLE ADJUSTING
7020201, 7025200, 7025207NW, 7025207PW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301
84834M
 
84834M BOLT
7025200, 7025500, 7028527, 7030200
84058M
 
84058M BOLT
7003207, 7008204, 7008208, 7008218EW, 7008226, 7008238, 7008248, 7008305, 7008425, 7010209, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028527, 7030200, 7030205, 7030301, 7040202, 7040206, 7040207PW, 704020
Back to top