84057M Mariner BOLT


84057M BOLT Mariner 7010209, 7015529, 7040202, 7040206, 7040207PW, 7040208, 7040208PW, 7040328, 7040507, 7040706, 7040716, 7048207, 7048227, 7048321, 7055324, 7055524, 7060507, 7060522, 7060528 BOLT
84057M BOLT Mariner
Rating:
73

Buy BOLT 84057M Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 73
 

Mariner entire parts catalog list:

7010209 1979,1983,1984,1985,1986
7015529 1979
7040202 1982,1985,1986
7040206 1986,1987,1988,1989
7040207PW 1989,1990,1991,1992,1993
7040208 1978
7040208PW 1989,1990,1991,1992,1993,1994,1995,1996,1997,1998
7040328 1978,1980
7040507 1987
7040706 1986,1990,1992
7040716 1986
7048207 1977
7048227 1977
7048321 1981
7055324 1984,1985,1988,1989
7055524 1984,1985
7060507 1977
7060522 1982
7060528 1978

Information:


Illustration 1 g01179736
Schematic for the Cat Data LinkTest Step 1. Inspect the Electrical Connectors and the Wiring
Remove the electrical power from the ECM.
Illustration 2 g01180182
Left side engine view (typical example) (1) J60 service tool connector (2) J1/P1 ECM connectors (3) J61 customer connector
Thoroughly inspect connectors (1), (2), and (3). Inspect all of the other connectors that are associated with the circuit for the Cat Data Link.Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Verify that the wiring for the Cat Data Link is installed correctly. Refer to Special Instruction, REHS1187, "Electronic Installation Guide".
Verify that each individual ECM is programmed to the proper engine location.
Illustration 3 g01091329
P1 terminals that are associated with the Cat Data Link (P1-8) Cat Data Link + (P1-9) Cat Data Link −
Illustration 4 g01130713
Terminals on the service tool connectors that are associated with the Cat Data Link (D) Cat Data Link + (E) Cat Data Link −
Illustration 5 g01179761
Terminals on the customer connectors that are associated with the Cat Data Link (6) Cat Data Link + (7) Cat Data Link −
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the Cat Data Link.
Check the allen head screw on each ECM connector and on the customer connector for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Check the wiring harnesses for abrasion, for corrosion, and for pinch points.Expected Result:All connectors, pins and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or the wiring.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the problem is resolved.STOPTest Step 2. Check for a Short Circuit
Remove the electrical power from the ECM.
Disconnect any service tools from the Cat Data Link.
Disconnect the P1 and P2 connectors from the ECM.
Measure the resistance between the points that are listed in Table 1. Be sure to wiggle the wires in the harnesses as you make each resistance measurement.
Table 1
Resistance Measurements for the Wiring Harness    
Connector and Terminal    Terminal    
P1-8 (Cat Data Link +)     All of the other terminals on the P1 connector    
All of the terminals on the P2 connector
Engine ground
P1-9 (Cat Data Link −)     All of the other terminals on the P1 connector    
All of the terminals on the P2 connector
Engine ground Expected Result:All of the resistance measurements indicate an open circuit.Results:
OK - All of the resistance measurements indicate an open circuit. Proceed to Test Step 3.
Not OK - At least one resistance measurement does not indicate an open circuit. There is a problem with a wiring harness. There may be a problem with a connector.Repair: Repair the wiring and/or the connector. Replace parts, if necessary. Verify that the problem is resolved.STOPTest Step 3. Check for an Open Circuit
Remove the electrical power from the ECM.
Use a jumper wire to create a short circuit between terminals P1-8 and P1-9.Note: Wiggle the harness during the following measurements in order to reveal any intermittent short condition.
Measure the resistance between the terminals for the Cat Data Link at the service tool connectors.Expected Result:Each resistance measurement is less than ten Ohms.Results:
OK - Each resistance measurement is less than ten Ohms. There is not an open circuit.Repair: The problem may be intermittent. If the problem is intermittent, refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - At least one resistance measurement is greater than ten Ohms. The wiring for the Cat Data Link has excessive resistance. There may be a problem in a connector.Repair: Repair the wire and/or the connector, when possible. Replace parts, if necessary. Verify that the problem is resolved.STOP


Parts bolt Mariner:

84237M
 
84237M BOLT
7002200, 7004201, 7005201, 7005207, 7008208, 7008238, 7008248, 7008305, 7015307, 7015327, 7020201, 7025200, 7025207NW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7040202, 7040206, 7040207, 7040207PW, 7040208, 7040328, 7040507, 704
82425M
 
82425M BOLT, PANEL ATTACHING...
7008238, 7008247, 7015207, 7015307, 7015327, 7028207, 7028527, 7048207, 7048227
82474M
 
82474M BOLT
7008204, 7008226, 7020201, 7025200, 7025500, 7028207, 7028527, 7040202, 7040207, 7040208, 7040328, 7040507, 7040716, 7060507, 7060522, 7060528
84427M
 
84427M BOLT (SUL) OPTIONAL
7040207, 7040507, 7048207, 7048227, 7048321, 7055324, 7055524, 7060507, 7060522, 7060528
81710M
 
81710M BOLT
7040207, 7040208, 7040507, 7048207, 7048227, 7048321, 7055324
83860M
 
83860M BOLT
7040208
94615M
 
94615M BOLT SEE NOTE #11
7010209, 7015529
41838M
 
41838M BOLT
7040207PW, 7040208PW, 7040706, 7040716, 7048321, 7055324, 7055524, 7060522
Back to top