851866 Mariner BOLT


851866 BOLT Mariner 7040203KL BOLT
851866 BOLT Mariner
Rating:
93

Buy BOLT 851866 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$7.31
 

23-12-2022
0.11[0.05] Pounds
-: -
The Hillman Group Hardware Essentials 851866 Zinc Ceiling Hooks (#6) - 2 Pieces, .192 x 3-3/8"
Great for hanging items throughout the home || While pre-drilling is not required, it is recommended for best results || Do not use to hang or lift loads || Curved lip prevents items from falling off hook || Holds up to 35 lbs..Zinc finish offers moderate corrosion resistance.2 pieces per package
$51.60
 

25-06-2021
4.5[1.80] Pounds
-: -
APDTY 851866 Power Window Regulator (Regulator Only)
Meets Or Exceeds OEM Specs || Factory OEM Fit Form And Function
Number on catalog scheme: 3
 

Compatible models:

7040203KL   Mariner

Mariner entire parts catalog list:

7040203KL 2001,2002,2003,2004,2006

Information:


Table 1
J1939 Code and Description Comments
100-3
Engine Oil Pressure : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
100-4
Engine Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
107-3
Engine Air Filter 1 Differential Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
107-4
Engine Air Filter 1 Differential Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
108-3
Barometric Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
108-4
Barometric Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
109-3
Engine Coolant Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
109-4
Engine Coolant Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
1208-3
Engine Pre-filter Oil Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
1208-4
Engine Pre-filter Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
4817-3
Engine Intake Manifold #1 Absolute Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
4817-4
Engine Intake Manifold #1 Absolute Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5631-3
Engine Throttle Valve Differential Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5631-4
Engine Throttle Valve Differential Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5708-3
Engine Coolant Pressure #2 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5708-4
Engine Coolant Pressure #2 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged. The ECM continuously creates a pull-up voltage on the signal wire for each sensor. The ECM uses this pull-up voltage to detect a problem in the signal circuit. When the ECM detects voltage that is above a threshold on the signal wire, the ECM activates a high voltage -3 diagnostic . When the ECM detects voltage that is below a threshold on the signal wire, the ECM activates a low voltage -4 diagnostic .Note: There may be a delay of 30 seconds in order for Cat® Electronic Technician (ET) to display an active diagnostic . When you check for a diagnostic , be sure to wait at least 30 seconds.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -3 code is active.
Proceed to Test Step 2.
Result: A -4 code is active.
Proceed to Test Step 3.
2. Create a Short at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor with the active -3 code.
C. Install the jumper wire between the following terminals at the sensor connector:
- Terminal 3 (signal) and Terminal 2 (sensor return)
D. Connect Cat ET.
E. Use Cat ET to monitor the following:
- -4 code
F. Turn the keyswitch to the OFF position.
Create a Short
Result: A -4 code did not become active.
Proceed to Test Step 4.
Result: A -4 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
3. Create an Open at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor with the active -4 code.
C. Connect Cat ET.
D. Use Cat ET to monitor the following:
- -3 code
E. Turn the keyswitch to the OFF position.
Create an Open
Result: A -3 code did not become active.
Proceed to Test Step 4.
Result: A -3 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
4. Check the 5 VDC Supply Voltage at the Sensor Connector
A. Turn the keyswitch to the ON position.
B. Measure the voltage at the sensor connector between the following pins:
- Pin 1 and Pin 2
C. Reconnect the sensor.
5.0 0.2 VDC
Result: The supply voltage is 5.0 0.2 VDC.
Proceed to Test Step 5.
Result: The supply voltage is not 5.0 0.2 VDC.
Repair:Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 5.
5. Perform the Wiggle Test
Carefully following this procedure is the best way to identify the root cause of an intermittent problem.
A. Connect Cat ET.
B. Use CAT ET to perform the following test:
- "Wiggle Test"
C. Slowly wiggle the wiring and the connectors between the P2 connector and the sensor. Pay particular attention to the wiring near each connector. Be sure to wiggle all the wiring.
As you wiggle the wiring look for these problems:
- Loose connectors or damaged connectors
- Moisture on the connectors


Parts bolt Mariner:

16705
 
16705 BOLT
7002201DK, 7002201HB, 7002201SK, 7002201UB, 7003201BK, 7004211SK, 7006201MK, 7006201UK, 7015203KL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7040203KL, 7040203UL, 7A25203UK, 7A25213UL, 7A25302UL, 7A3G312U
823042 13
 
823042 13 BOLT
7002201HB, 7004201HB, 7040203KL, 7A25203UK, 7A25213UL, 7A25302UL, 7A3G312UK, 7F04201JB, 7F08201TB
16223 2
 
16223 2 BOLT
7040203KL, 7040203UL, 7F042016B, 7F04201JB
823042 7
 
823042 7 BOLT, (M6 x 12)
7006201UK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7040203KL, 7040203UL, 7A25203UK, 7A25213UL, 7A25302UL, 7A3G312UK, 7F02201ZK, 7F042016B, 7F08201TB, 7F15311ZK
95396 5
 
95396 5 BOLT
7040203KL, 7040203UL
851866 4
 
851866 4 BOLT
7040203KL, 7040203UL, 7F08201TB, 7F15311ZK
16263 7
 
16263 7 BOLT
7040203KL, 7040203UL
823042 15
 
823042 15 BOLT
7040203KL
Back to top