9798M Mariner CLAMP BRACKET, STARBOARD


9798M CLAMP BRACKET, STARBOARD Mariner 7025207PW, 7025208CW, 7025500, 7026226, 7030205, 7030301, 7030320 CLAMP
9798M CLAMP BRACKET, STARBOARD Mariner
Rating:
58

Buy CLAMP BRACKET, STARBOARD 9798M Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 16
 

Mariner entire parts catalog list:

7025207PW 1989,1990,1991,1992,1993
7025208CW 1994,1995,1996,1997,1998
7025500 1980
7026226 1986,1988
7030205 1985,1986,1987,1988,1989,1990
7030301 1981
7030320 1980,1990,1992

Information:

Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use a solution that is identified below.Problem
Failures of the 258-8725 Water Pump Gp (Jacket Water) on the above generator set engines have been reported. The primary failure mode has been coolant leaks through the pump's weep hole due to a damaged water seal.Damage to the water seal occurs when a seal overheats. Dry running of the pump or pump cavitation will cause overheating of the water seal.The characteristics of the design of the pump are being evaluated. The following factors are the main contributors to dry running water pump seals and water pump cavitation:
Application
Installation
Design of the cooling system
Maintenance
OperationSolution
The above problem continues to be investigated. In the interim, Caterpillar recommends the following solution:
The cooling systems must be designed to Caterpillar requirements.
Ensure that the following proper maintenance practices are used: filling procedure for coolant, engine starting procedures, check for external restrictions and purge air from the cooling system.Filling and Venting
While the coolant system is filled, air can be trapped. Proper filling and venting will minimize these air pockets. Refer to the Application and Installation Guide, LEBW4978, "Cooling Systems" for details about filling and venting. Also follow the guidelines for filling and venting the cooling system.
The engine must be filled from the bottom with coolant at a rate no faster than 19 L (5 US gal) per minute. The cap must be removed from the expansion tank during filling of the cooling system.
The vent line must be routed with a continuous upward slope from the highest point of the engine's cooling system to the bottom of the expansion tank.For a system with a volume that is greater than 284 L (75 US gal), the vent lines must be a minimum diameter of 9 mm (3/8 inch).For a system with a volume that is greater than 568 L (150 US gal), the vent lines must be a minimum diameter of 13 mm (1/2 inch).Engine Start-Up
Perform the following procedures in order to ensure that the air is purged after a cooling system has been filled:
Do not accelerate the engine directly to high idle speed.
Run the engine at low idle speed for approximately ten minutes.
During the initial ten minutes of running, monitor the expansion tank and maintain the coolant level above the minimum mark.Design of the Cooling System
The design of the cooling system must be evaluated if the commissioning procedure for the cooling system has not been completed successfully.All systems must be designed as shown in the guidelines in Application and Installation Guide, LEBW4978, "Cooling Systems".Refer to Engine Data Sheet, LEKQ8288, "Sizing Customer Furnished Cooling Systems" for sizing information for the cooling system.For guidelines for the field test of the cooling system, refer to Engine Data Sheet, LEKQ7235, "Cooling System Field Test". The field test of the cooling system must be completed during the engine commissioning. This must be considered when pump failures occur.Pump failures that are associated with poor design of the cooling system are typically caused by the following:
Excess system restriction
The lack of a shunt line
Low system pressure after shutdowns
Undersized expansion tanksExpansion Tank
In order to absorb an after-boil that may occur during a hot shutdown, the expansion tank must be sized properly.An expansion tank in a jacket water system that is a standard temperature must be a minimum of 15 percent of total volume of the system.An expansion tank in a jacket water system that is high temperature that is greater than 100 °C (212 °F) must be a minimum of 25 percent of total volume of the system.Pressure Cap
In order to help prevent an after-boil that may occur during a hot shutdown, the proper pressure cap must be installed. The pressure of the system must be 27.5 to 34.4 kPa (4 to 5 psi) above the pressure that forms steam.A pressure cap for a standard engine is typically 27.5 to 48.2 kPa (4 to 7 psi).A pressure cap for an engine that is in a landfill application is typically 130.9 to 151.6 kPa (19 to 22 psi). Information that Must be Reported to the Dealer Solution Network (DSN) in the Event of a Failure of a 258-8725 Water Pump Gp (Jacket Water)
In the event of a pump failure have your technical communicator contact the DSN as soon as possible. Supply the following information to the DSN:
Description of the problem
Provide a data log from Caterpillar Electronic Technician (ET) at no load and rated load from a cold start with the following parameters: jacket water pressure, jacket water coolant temperature, engine load, engine speed, oil temperature and oil pressure
Describe the initial commissioning procedure.
Describe the procedure for engine start-up after cooling system maintenance is performed.
Table 1
Cooling System Audit    
Product Name:     Date:    
Dealer Code:     Dealer Contact:    
Sales Model:     Serial Number(s):    
Site Location:     Altitude (Feet above sea level):    
Design Ambient (Max °F):        
Cooling System Type (Circle One):    
Radiator     Heat Exchanger     Keel Cooling     Cooling Tower        
Manufacturer:     System Designer:    
Cooling System Capacity
(Gal) Per Engine:     Coolant Type:    
Cooling System Schematic (Circle One):    
Attached     Not Available     Forthcoming        
Cooling System Design Features (Circle All That Apply)    
Expansion Tank     Shunt Line     Engine
Thermostats     Filters     Thermostat Bypass     Inlet
Temperature
Control    
System/Component Dimensions (Fill In)    
Radiator:     Pipe Dim
Length and Dia:     Number Of Elbows
Dia. and Angle:    
Shunt Line
ID in Inches:     Rad Cap PSI:     Thermostat Type:    
External
Restriction: (1)     Vent Line
ID in Inches:     Expansion Tank Volume (Gal):    
Pressures     Start Up     Rated load     Not Running    
Inlet Outlet     Inlet     Outlet     Inlet     Outlet    
Jacket Water Pump                            
Engine                            
Actual
Temperature                        


Parts clamp Mariner:

83577M
 
83577M CLAMP
7002200, 7030320, 7040207, 7040208, 7040507, 7055324, 7115F13KD, 7115F13RD, 7115F13UF, 7F10203HD, 7F13203UB, 7F15201GD, 7F75411JD, 7F75412RD, 7F75413TD
96348M
CLAMP
96348M CLAMP
7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7030205, 7030320
96352M
CLAMP
96352M CLAMP
7020201, 7025200, 7025500, 7026226
96353M
CLAMP
96353M CLAMP
7020201, 7025200, 7025500, 7026226
99952M
 
99952M CLAMP
7020201, 7025200, 7025207PW, 7025208CW, 7025500, 7026226
9797M
 
9797M CLAMP BRACKET, PORT
7025207PW, 7025208CW, 7025500, 7026226, 7030205, 7030301, 7030320
96654M
 
96654M CLAMP
7030301, 7030320
811185M
 
811185M CLAMP
7030320
Back to top