817070 Mariner DRIVESHAFT HOLDING TOOL


817070 DRIVESHAFT HOLDING TOOL Mariner 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7055207GD, 7055207HB, 7055207TF, 7A30302LB, 7A30453VZ, 7A40302UD, 7A40302ZZ, 7A40312UZ, 7A40312ZZ, 7A40412ZZ, 7A41412LB, 7A41452I DRIVESHAFT
817070 DRIVESHAFT HOLDING TOOL Mariner
Rating:
8

Buy DRIVESHAFT HOLDING TOOL 817070 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: -
 

Mariner entire parts catalog list:

70432037D 1997,1998
7043213HD 1999,2000,2001,2002,2003,2004
7043213TD 2005
7043302TD 2005
7043412TB 2005,2006
7043412TD 2005
7050312TB 2005
7050312UB 2006
7050412TB 2005
7050412TD 2005
7050412UB 2006
7055207GD 1998
7055207HB 1999,2000,2001,2002,2003,2004
7055207TF 2005,2006
7A30302LB 2002,2003,2004,2005
7A30453VZ 2010
7A40302UD 2006
7A40302ZZ 2006
7A40312UZ 2006
7A40312ZZ 2006
7A40412ZZ 2006
7A41412LB 2002,2003,2004,2005,2006
7A41452IZ 2006
7A41452UZ 2006
7A51412ZZ 2006
7A51452IZ 2006
7A60412ZZ 2006
7A60452IZ 2006
7E41412ZB 2006
7E51412ZB 2006
7E51413VZ 2010
7E60412ZB 2006
7E60413VZ 2010
7E60452IZ 2007
7E60452ZB 2006
7F40452KD 2001
7F40452LB 2002
7F41452KB 2001,2002
7F41452KD 2001

Information:


Table 1
Diagnostic Codes Table    
Code and Description    Conditions which Generate this Code    System Response    
E255(1) Diagnostic Reset     The engine's Electronic Control Module (ECM) detects ground on the input for the protection override switch.     If an engine derate or an engine shutdown is active, the derate or the shutdown will be overridden.
The code is logged.    
System OperationIf full engine power is needed, the protection override switch allows the user to override an engine derate or an engine shutdown. The wire for the protection override switch is routed from the ECM to the customer connector. The wire is then routed to a customer supplied switch.
Illustration 1 g01355311
Typical schematic
Illustration 2 g01355312
P1 ECM connector (P1-62) Protection override switch
Illustration 3 g01355313
Customer connector C-C18 (Terminal Z) Protection override switchTest Step 1. Check for an "Active" Event Code
Restore electrical power to the ECM.
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.
Activate the protection override switch.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.Expected Result:A E255 event code is not active if the protection override switch is in the OFF position. A E255 event code is active if the protection override switch is in the ON position.Results:
OK - The circuit is operating correctly.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - An event code is not active when the protection override switch is in the ON position. An event code is active when the protection override switch is in the OFF position. Proceed to Test Step 2.Test Step 2. Check the Signal Wire between the Protection Override Switch and the ECM
Disconnect the wire N715-BK from the protection override switch.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.
Connect the wire N715-BK to engine ground.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.Expected Result:A E255 event code is not active if the wire N715-BK is open. A E255 event code is active if the wire N715-BK is grounded.Results:
OK - The wiring between the ECM and the protection override switch is OK.Repair: The problem is most likely in the protection override switch. Replace the switch.STOP
Not OK - An event code is not active when the wire N715-BK is grounded. An event code is active when the wire N715-BK is open. Proceed to Test Step 3.Test Step 3. Check the Signal Wire between the Customer Connector and the ECM
Disconnect the wire N715-BK from terminal Z of the customer connector.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.
Connect wire N715-BK to engine ground.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.Expected Result:A E255 event code is not active if the wire N715-BK is open. A E255 event code is active if the wire N715-BK is grounded.Results:
OK - The wiring between the ECM and the customer connector is OK.Repair: The problem is in the wiring between the protection override switch and the customer connector. Repair the wire.STOP
Not OK - An event code is not active when the wire N715-BK is grounded. An event code is active when the wire N715-BK is open. Proceed to Test Step 4.Test Step 4. Check the Signal at the ECM
Disconnect the wire N715-BK from the P1-62 ECM connector.
Fabricate a jumper wire that can be used to replace the signal wire in the ECM connector for the protection override switch. Crimp a connector socket to one end of the jumper wire.
Install the jumper wire into the terminal location for the protection override switch. Ensure that the wire is open.
Connect the ECM connector.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.
Connect the jumper wire to engine ground.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if a E255 event code is active.Expected Result:A E255 event code is not active if the jumper wire is open. A E255 event code is active if the jumper wire is grounded.Results:
OK - The ECM is operating correctly.Repair: The problem is in the wiring between the ECM connector and the customer connector. Repair the wire.STOP
Not OK - An event code is not active when the jumper wire is grounded. An event code is active when the jumper wire is open.Repair: Replace the ECM. Refer to Troubleshooting, "ECM - Replace".STOP


Parts driveshaft Mariner:

816528A 1
 
816528A 1 DRIVESHAFT HOUSING (SHORT) (BLACK)
7050302ED, 7050412YD, 7055207GD, 7055207HB, 7055207TF, 7060412ET
816528A 2
 
816528A 2 DRIVESHAFT HOUSING (SHORT) (GRAY)
7050302ED, 7050412YD, 7055207GD, 7060412ET
9864A 6
 
9864A 6 DRIVESHAFT HOUSING (LONG) (BLACK)
7050302ED, 7050412YD, 7055207GD, 7060412ET
821841A 8
801413401
 
801413401 DRIVESHAFT
70432037D, 7043213HD
822159T 1
 
822159T 1 DRIVESHAFT
7031312TB, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB
891549T
 
891549T DRIVESHAFT, Short
7A30453VZ, 7A40302ZZ, 7A40312ZZ, 7A40412ZZ, 7F40203ZZ
880184
DRIVESHAFT
880184 DRIVESHAFT
7A41452IZ, 7A41452UZ, 7A51412ZZ, 7A51452IZ, 7A60412ZZ, 7A60452IZ, 7E41412ZB, 7E51412ZB, 7E51413VZ, 7E60412ZB, 7E60413VZ, 7E60452IZ, 7E60452ZB
Back to top