815045 FUEL COCK Mariner
7004201HB, 7004201UB, 7004211SK
FUEL

Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
FVDLktL Fuel Cock Tap Switch for Outboard Engine 4HP 5HP 815045 22-815045-00 22815045 22-815045-0 Boat Motor Replacement Parts
FVDLktL Compatibility: Designed for 4HP and 5HP outboards to ensure a good match. || Replacement Model: Replaces models 815045, 22-815045-00 and 22815045. || Function: Controls fuel flow to ensure stable engine operation. || Durability: Made of high-performance materials, it has good corrosion resistance and durability. || Safety: Effectively prevents fuel leakage to ensure safe operation.
FVDLktL Compatibility: Designed for 4HP and 5HP outboards to ensure a good match. || Replacement Model: Replaces models 815045, 22-815045-00 and 22815045. || Function: Controls fuel flow to ensure stable engine operation. || Durability: Made of high-performance materials, it has good corrosion resistance and durability. || Safety: Effectively prevents fuel leakage to ensure safe operation.
WKNYSYK Fuel Cock Assy Switch 22-815045 815045 for Engine 2 Stroke 4 4.5 5 40 HP Outboard Motor Cock-Fuel 22-815045-00 22815045 Replacement Parts
WKNYSYK Built to strict control standards for wonderful performance. || Precision manufacturing makes it has stable performance || Made of high-quality materials, durable and practical. || Excellent quality you can trust || Advanced manufacturing process
WKNYSYK Built to strict control standards for wonderful performance. || Precision manufacturing makes it has stable performance || Made of high-quality materials, durable and practical. || Excellent quality you can trust || Advanced manufacturing process
Fuel Cock Tap Switch Compatible with 4HP 5HP Boat Motor Engine Accessories 22-815045-0 815045 22-815045-00
hHTRZ Designed Compatible With compatibility with boat motors, this fuel cock tap switch fits models with 4HP and 5HP engines. || Engineered using materials, this switch ensures durability and reliable performance under marine conditions. || Installation-friendly design allows Compatible With easy replacement of your existing fuel tap switch, enhancing convenience during maintenance. || This fuel cock tap switch is a direct replacement Compatible With part number 22-815045-0, ensuring a fit and function. || Ideal Compatible With various marine applications, this switch is essential Compatible With controlling fuel flow in your boat, optimizing engine performance. || The compact size and lightweight design of the switch make it an effortless addition to your engine accessories. || Invest in this fuel cock tap switch to maintain and in your boat motor.
hHTRZ Designed Compatible With compatibility with boat motors, this fuel cock tap switch fits models with 4HP and 5HP engines. || Engineered using materials, this switch ensures durability and reliable performance under marine conditions. || Installation-friendly design allows Compatible With easy replacement of your existing fuel tap switch, enhancing convenience during maintenance. || This fuel cock tap switch is a direct replacement Compatible With part number 22-815045-0, ensuring a fit and function. || Ideal Compatible With various marine applications, this switch is essential Compatible With controlling fuel flow in your boat, optimizing engine performance. || The compact size and lightweight design of the switch make it an effortless addition to your engine accessories. || Invest in this fuel cock tap switch to maintain and in your boat motor.
Mariner entire parts catalog list:
- FUEL TANK » 815045
- FUEL TANK » 815045
- FUEL TANK (SERIAL GROUP #2) » 815045
- FUEL TANK (SERIAL GROUP #1) » 815045
Information:
Procedure For Protective Relaying Programming
Note: Service Mode cannot be accessed when the engine control switch (ECS) is in the AUTO position.Note: An active shutdown fault is indicated by a FLASHING shutdown indicator. An active shutdown fault must be made inactive in order to access service mode. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must no longer be occurring. The fault must be corrected. The ECS must be returned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 4" is showing on the lower display. For more information, see System Operation, "Password Entry OP3".
Press "CROLL UP" key two times. "OP5-1" is showing on the lower display.
Press "SELECT" key once. "P101" is showing. "P101" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the setpoint value. Repeat this step until the desired setpoint is showing.
Press "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" or the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: In order to rapidly scroll through a large range of values, press and hold the appropriate "SCROLL" key.
Press "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6 and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display returns to normal mode.
Table 1
OP5-1 Setpoints (1) - Protective Relaying Programming
Setpoint Name Description Range Of Value Factory Default
P101 Overvoltage Alarm Enable The GSC+ enables the generator alarm function or the GSC+disables the generator alarm function. 0 - disabled
1 - enabled 1
P102 Overvoltage Alarm Threshold Voltage the GSC+ uses to issue an overvoltage alarm. 100 to 125% of nameplate voltage in increments of 1% 105%
P103 Overvoltage Alarm Time Delay Amount of time the GSC+ waits before issuing an overvoltage alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P104 Overvoltage Shutdown Enabled The GSC+ enables or disables the generator overvoltage shutdown function. 0 - disabled
1 - enabled 1
P105 Overvoltage Shutdown Threshold Voltage the GSC+ uses to issue an overvoltage shutdown. 100 to 125% of nameplate voltage in increments of 1% 110%
P106 Overvoltage Shutdown Time Delay Amount of time the GSC+ waits before inssuing an overvoltage shutdown. 0 to 120 seconds (2) in increments of 1 10 seconds
P107 Undervoltage Alarm Enable The GSC+ enables or disables the generator undervoltage alarm function. 0 - disabled
1 - enabled 1
P108 Undervoltage Alarm Threshold Voltage the GSC+ uses to issue an undervoltage alarm. 60 to 100% of nameplate voltage in increments of 1% 90%
P109 Undervoltage Alarm Time Delay Amount of time the GSC+ waits before inssuing an undervoltage alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P110 Undervoltage Shutdown Enable The GSC+ enables or disables the generator undervoltageshutdown function. 0 - disabled
1 - enabled 1
P111 Undervoltage Shutdown Threshold Voltage the GSC+ uses to issue an undervoltage shutdown. 60 to 100% of nameplate voltage in increments of 1% 85%
P112 Undervoltage Shutdown Time Delay Amount of time the GSC+ waits before issuing an undervoltage shutdown. 0 to 120 seconds (2) in increments of 1 15 seconds
P113 Overfrequency Alarm Enable The GSC+ enables or disables the generator overfrequency alarm function. 0 - disabled
1 - enabled 1
P114 Overfrequency Alarm Threshold Frequency that the GSC+ uses to issue an overfrequency alarm. 50 to 60, for 50 Hz GEN
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen 53 Hz
63 Hz
422 Hz
P115 Overfrequency Alarm Time Delay Amount of time the GSC+ waits before issuing an overfrequency alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P116 Overfrequency Shutdown Enable The GSC+ enables or disables the generator overfrequency shutdown function. 0 - disabled
1 - enabled 1
P117 Overfrequency Shutdown Threshold Frequency the GSC+ uses to issue an overfrequency shutdown. 50 to 60, for 50 Hz Gen
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen 55Hz
63 Hz
422 Hz
Note: Service Mode cannot be accessed when the engine control switch (ECS) is in the AUTO position.Note: An active shutdown fault is indicated by a FLASHING shutdown indicator. An active shutdown fault must be made inactive in order to access service mode. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must no longer be occurring. The fault must be corrected. The ECS must be returned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 4" is showing on the lower display. For more information, see System Operation, "Password Entry OP3".
Press "CROLL UP" key two times. "OP5-1" is showing on the lower display.
Press "SELECT" key once. "P101" is showing. "P101" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the setpoint value. Repeat this step until the desired setpoint is showing.
Press "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" or the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: In order to rapidly scroll through a large range of values, press and hold the appropriate "SCROLL" key.
Press "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6 and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display returns to normal mode.
Table 1
OP5-1 Setpoints (1) - Protective Relaying Programming
Setpoint Name Description Range Of Value Factory Default
P101 Overvoltage Alarm Enable The GSC+ enables the generator alarm function or the GSC+disables the generator alarm function. 0 - disabled
1 - enabled 1
P102 Overvoltage Alarm Threshold Voltage the GSC+ uses to issue an overvoltage alarm. 100 to 125% of nameplate voltage in increments of 1% 105%
P103 Overvoltage Alarm Time Delay Amount of time the GSC+ waits before issuing an overvoltage alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P104 Overvoltage Shutdown Enabled The GSC+ enables or disables the generator overvoltage shutdown function. 0 - disabled
1 - enabled 1
P105 Overvoltage Shutdown Threshold Voltage the GSC+ uses to issue an overvoltage shutdown. 100 to 125% of nameplate voltage in increments of 1% 110%
P106 Overvoltage Shutdown Time Delay Amount of time the GSC+ waits before inssuing an overvoltage shutdown. 0 to 120 seconds (2) in increments of 1 10 seconds
P107 Undervoltage Alarm Enable The GSC+ enables or disables the generator undervoltage alarm function. 0 - disabled
1 - enabled 1
P108 Undervoltage Alarm Threshold Voltage the GSC+ uses to issue an undervoltage alarm. 60 to 100% of nameplate voltage in increments of 1% 90%
P109 Undervoltage Alarm Time Delay Amount of time the GSC+ waits before inssuing an undervoltage alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P110 Undervoltage Shutdown Enable The GSC+ enables or disables the generator undervoltageshutdown function. 0 - disabled
1 - enabled 1
P111 Undervoltage Shutdown Threshold Voltage the GSC+ uses to issue an undervoltage shutdown. 60 to 100% of nameplate voltage in increments of 1% 85%
P112 Undervoltage Shutdown Time Delay Amount of time the GSC+ waits before issuing an undervoltage shutdown. 0 to 120 seconds (2) in increments of 1 15 seconds
P113 Overfrequency Alarm Enable The GSC+ enables or disables the generator overfrequency alarm function. 0 - disabled
1 - enabled 1
P114 Overfrequency Alarm Threshold Frequency that the GSC+ uses to issue an overfrequency alarm. 50 to 60, for 50 Hz GEN
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen 53 Hz
63 Hz
422 Hz
P115 Overfrequency Alarm Time Delay Amount of time the GSC+ waits before issuing an overfrequency alarm. 0 to 120 seconds (2) in increments of 1 10 seconds
P116 Overfrequency Shutdown Enable The GSC+ enables or disables the generator overfrequency shutdown function. 0 - disabled
1 - enabled 1
P117 Overfrequency Shutdown Threshold Frequency the GSC+ uses to issue an overfrequency shutdown. 50 to 60, for 50 Hz Gen
60 to 70, for 60 Hz Gen
400 to 480, for 400 Hz Gen 55Hz
63 Hz
422 Hz
Parts fuel Mariner:
824964A 2
16240
16248
16248 FUEL FILTER
7004201HB, 7004201UB, 7004211SK, 7006201MK, 7006201UK, 7F042016B, 7F04201JB, 7F08201TB, 7F15311ZK
15781A 5
15781A 5 FUEL CONNECTOR
7004201HB, 7004201UB, 7004211SK, 7A25203UK, 7A25213UL, 7A25302UL, 7A3G312UK, 7B25201GF, 7F042016B, 7F04201JB, 7F08201TB, 7F08203HF, 7F08261DF, 7F10203HD, 7F13203UB, 7F15201GD, 7F15311ZK
95394 9
95394 9 FUEL LINE
7002201HB, 7002201UB, 7004201HB, 7004201UB, 7015203KL, 7030201KL, 7031207LF, 7040203KL, 7F042016B, 7F04201JB