96278 Mariner GASKET


96278 GASKET Mariner 7135826, 7150629, 7175629, 7200620 GASKET
96278 GASKET Mariner
Rating:
103

Buy GASKET 96278 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

Compatible models:

Mariner entire parts catalog list:

7135826 1986,1987,1988
7150629 1979,1980,1982,1984,1985
7175629 1979,1980,1985,1986,1988
7200620 1980,1982,1983,1984,1985,1986,1988

Information:


Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
444-5 Starter Motor Relay current below normal The Electronic Control Module (ECM) detects an open circuit and/or a short to the +Battery in the start relay. The ECM can only detect this condition when the start relay is not energized. The code is logged.
444-6 Starter Motor Relay current above normal The ECM detects a short circuit to ground in the start relay. The ECM can only detect this condition when the start relay is energized. The ECM has the ability to crank the engine when the Engine Control Switch (ECS) is placed in the START position. After the ECS is placed in the START position, the ECM will begin the prelube cycle. The ECM will send an engine start signal to terminal BH of the customer connector after the prelube cycle is complete. The customer's engine start signal will return on terminal BJ of the customer connector. The signal is then sent to terminal 10 of the G-C6 connector on the "Marine Power Display (MPD)" panel.If a "Starter Select Switch" is installed in the MPD panel, the switch can be set to use either the electric starting motors or the air starting motors. If electric starting motors are installed on the engine, the starting motor relays "SMMS1" and "SMMS2" will be energized. If air starting motors are installed on the engine, the air start solenoids will be energized. If a "Starter Select Switch" is not installed in the MPD panel, the start signal is routed from TB-8 to TB-7. The signal from TB-7 is wired to the starting system. The crank cycle will continue for the time that is equal to the cycle crank time that has been programmed or the crank cycle will continue until the engine speed reaches the crank terminate speed.Note: The prelube cycle can be disabled by setting the duration of the prelube cycle to 0.This process will repeat for a programmed amount of times "Total Number of Crank Cycles". If the engine does not start, Caterpillar Electronic Technician (ET) will display "OVERCRANK". The engine control will be in an idle state. The process can be restarted by turning the ECS to the OFF/RESET position. Next, turn the ECS to the STOP position. Then turn the ECS to the START position.The engine can be manually started by using the "crank override switch" which is located on the in


Parts gasket Mariner:

6452
 
6452 GASKET KIT
7135417PD, 7135826, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175629, 7200412PD, 7200620
67274 1
 
67274 1 GASKET
7135417PD, 7150453PD, 7150629, 7175412PD, 7175629, 7200620
67275 1
 
67275 1 GASKET
7135417PD, 7150453PD, 7150629, 7175412PD, 7175629, 7200620
90430
 
90430 GASKET
7135826, 7150453ND, 7150629, 7175629, 7200620
42631 1
 
42631 1 GASKET
7002201DK, 7115473JD, 71354120D, 7135412AD, 7135412ED, 7135412HD, 7135412JD, 7135417PD, 7135473GD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413ED, 7150413HD, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7150423JD, 7150453ND, 7150453P
41246 1
 
41246 1 GASKET
7175629, 7200620
75909
 
75909 GASKET
7175629
12775 4
 
12775 4 GASKET
7200620
Back to top