853740 2 Mariner GROUND WIRE


853740 2 GROUND WIRE Mariner 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF GROUND
853740 2 GROUND WIRE Mariner
Rating:
83

Buy GROUND WIRE 853740 2 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 36
 

Mariner entire parts catalog list:

7025207UL 2006
7025217UL 2006
7030201KL 2001,2002,2003,2004
7030201UL 2006
7030211U2 2006
7030A01UL 2006
7030A11UL 2006
7031207LF 2002,2003

Information:


Table 1
Diagnostic Trouble Codes
J1939 Code Code Description Comments
4215-3 Ground-Level Shutdown Activated : Voltage Above Normal If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.
4215-4 Ground-Level Shutdown Activated : Voltage Below Normal If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.
4215-31 Ground-Level Shutdown Activated The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged. The shutdown switch will shut down the engine. The engine ECM remains active. Caterpillar Electronic Technician (ET) can be used to communicate with the ECM. The shutdown switch must be returned to the RUN position before the ECM will allow the engine to start.The ECM reads the position of the shutdown switch. If the engine is running, the ECM disables the fuel injection. The status screen will display "Injection Disabled" and "Remote Shutdown".
Illustration 1 g03018516
Schematic
Table 2
Troubleshooting Test Steps Values Results
1. Determine the Diagnostic Code
A. Establish communication between Cat ET and the ECM . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Observe the "Active Diagnostic" screen on Cat ET. Wait at least 30 seconds so that any codes may become active.
C. Look for these codes:
- 4215-31
- 4215-3
- 4215-4
Diagnostic Trouble codes
Result: A 4215-31 diagnostic code is active.
Proceed to Test Step 2.
Result: A 4215-3 diagnostic code is active.
Proceed to Test Step 3.
Result: A 4215-4 diagnostic code is active.
Proceed to Test Step 4.
2. Check the Status of the Shutdown Switch on Cat ET
A. Activate the shutdown.
B. Use Cat ET to verify that the engine rpm is 0. Return the shutdown switch to the RUN position.
C. Use Cat ET to observe the status of the shutdown switch.
Switch status
Result: The status of the shutdown switch changed states after returning the shutdown switch to the RUN position.
The shutdown switch is operating correctly.
Result: The status of the shutdown switch does not change states after returning the shutdown switch to the RUN position.
Proceed to Test Step 3.
3. Create a Short at the Connector for the Shutdown Switch
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the shutdown switch.
C. Create a short circuit at the connector for the shutdown switch between terminal 1 and terminal 2.
D. Turn the keyswitch to the ON position.
E. Use Cat ET to observe the status of the shutdown switch.
F. Remove the wire short.
Short circuit
Result: The status of the shutdown switch changed states after creating the short circuit.
Install a new shutdown switch.
Verify that the problem is resolved.
Result:The status of the shutdown switch did not change states after creating the short circuit.
Repair the wiring or replace the harness.
Use Cat ET to verify that the problem is resolved.
4. Create an Open at the Connector for the Shutdown Switch
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the shutdown switch.
C. Turn the keyswitch to the ON position.
D. Use Cat ET to observe the status of the shutdown switch.
Open circuit detected
Result: The status of the shutdown switch changed states after creating the open circuit.
Install a new shutdown switch.
Use Cat ET to verify that the problem is resolved.
Result: The status of the shutdown switch did not change states after creating the open circuit.
Repair the harness or replace the harness.
Use Cat ET to verify that the problem is resolved.
Complete the procedure in the order in which the steps are listed.


Parts ground Mariner:

803820
GROUND WIRE
803820 GROUND WIRE
7006201UK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF
853740
GROUND WIRE
853740 GROUND WIRE
7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF
853740 1
 
853740 1 GROUND WIRE
7030201KL, 7031207LF, 7040203KL, 7040203UL, 7F08201TB
Back to top