18844M Mariner HOUSING, OIL SEAL


18844M HOUSING, OIL SEAL Mariner 7004201, 7005201, 7005207 HOUSING
18844M HOUSING, OIL SEAL Mariner
Rating:
63

Buy HOUSING, OIL SEAL 18844M Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$3.50
 

09-01-2023

-: -
InLine 18844M Câble Noir
Number on catalog scheme: 10
 

Compatible models:

Mariner entire parts catalog list:

7004201 1981,1985,1988,1989
7005201 1981,1985,1988,1989
7005207 1977

Information:


Table 1
G3500 A/F Ratio Parameter Identifiers (PID)
PID Description Resolution/Data Data Range Length
0001 aa # Of Speed Sensitive Timing Maps Available 1 map per bit 0 to 6 Bits 8 - 1 (aa)
0002 aa Speed Sensitive Timing Map in Use 0 = disabled
1 = map #1 enabled
2 = map #2 enabled, etc. 0 to 6 Bits 8 - 1 (aa)
0003 aa Detonation 00 - 09 = 1 bar
10 - 12 = 2 bars
13 - 15 = 3 bars
16 - 17 = 4 bars
18 = 5 bars
19 - 20 = 6 bars
21 = 7 bars
22 - 26 = 8 bars
27 - 31 = 9 bars
32 - 255 = 10 bars 0 to 255 Bits 8 - 1 (aa)
0007 aa # of Detonation Sensors 0 = no sensors
1 = 1 sensor, etc. 0 to 2 Bits 8-1 (aa)
0008 aa Engine Type High Nibble = family
Low Nibble = # cyls.
i.e. 5 = 3500 family
F = 16 cyls.
5F = 3516 Engine 0 to 255 Bits 8 - 1 (aa)
000C aa Oxygen Sensor Status bit 8 1 = start cal.
bit 7 1 = cal. in progress
bit 6 1 = sensor on (status)
bit 5 1 = command sensor on 0 to F0 Bits 8 - 1 (aa)
0011 aa Ignition Timing Calibration bit 8 1 = cal. good
bit 8 0 = cal. bad
bit 7 1 = enable cal.
bit 7 0 = disable cal. 0 to C0 Bits 8-1 (aa)
0016 aa Inlet Manifold Temp 1 degree C per bit 0 to 255 Bits 8 - 1 (aa)
0040 aabb Actual Engine RPM 0.5 rpm per bit 0 to 16383 rpm Bits 16-9 (aa)
Bits 8-1 (bb)
0041 aabb Actual Ignition Timing 0.1 degree per bit 0 to 400
0 to 40 degrees Bits 16-9 (aa)
Bits 8-1 (bb)
0046 aabb Desired Engine Speed 0.5 rpm per bit 0 to 6400
0 to 3200 rpm Bits 16-9 (aa)
Bits 8-1 (bb)
0047 aabb Desired Ignition Timing 0.1 degree per bit 0 to 400
0 to 40 degrees Bits 16-9 (aa)
Bits 8-1 (bb)
004B aabb Rated Engine Speed 0.5 rpm per bit 0 to 32767 rpm Bits 16-9 (aa)
Bits 8-1 (bb)
005D aabb Inlet Manifold Pressure 1 kPa per bit 0 to 6383 kPa Bits 16-9 (aa)
Bits 8-1 (bb)
0080 mb Device ID Code 12,00,01,00,61,00
12,00 = MID
01,00 = Software Version
61,00 = Application Type 6 Bytes
0082 mb Diagnostic Codes aabbcc...
aabb CID
cc - FMI
Refer to IID 82 0 - 27 Bytes
0086 mb Software Date Code aa aa aa = month
bb bb = year
i.e. 53 45 50 = S E P
39 35 = 9 5 5 Bytes
F108 aa Speed Governor Aux. #1 Proportional Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F109 aa Speed Governor Aux. #1 Internal Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F10A aa Speed Governor Aux. #1 Derivative Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F10B aa Speed Governor Primary Proportional Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F10C aa Speed Governor Primary Integral Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F10D aa Speed Governor Primary Derivative Gain Adjustment 1 unit per bit (signed) -30 to +30 Bits 8 - 1 (aa)
F113 aa Engine Operation bit 8 0 = genset
bit 8 1 = industrial
bit 6 0 = isochronous governor
bit 6 1 = droop governor Bits 8 - 1 (aa)
F11B aa Engine Compression Ratio 0.1:1 ratio per bit 0:1 to 22.3:1 Bits 8 - 1 (aa)
F11C aa Air/Fuel Ratio Control Proportional Gain Adjustment Factor 1 unit per bit -30 to +30 Bits 8 - 1 (aa)
F11D aa Air/Fuel Ratio Control Integral Gain Adjustment Factor 1 unit per bit -30 to +30 Bits 8 - 1 (aa)
F121 aa EIS Mode bit 8 1 = master
bit 8 2 = slave Bits 8 - 1 (aa)
F122 aa # of Load Sensitive Ignition Timing Maps Available 1 = 1 map
2 = 2 maps, etc.
0 = disabled 0 to 2 Bits 8 - 1 (aa)
F123 aa Load Sensitive Timing Map in Use 1 = # 1
2 = # 2
0 = disable 0 to 2 Bits 8 - 1 (aa)
F124 aa EIS Special Test Status bit 8, 1 = enable special test
bit 8, 0 = disable
bits 5-1, 0 = test passed
bits 5-1, non zero = # of tests failed Bits 8 - 1 (aa)
F125 aa Air/Fuel Ratio Enable/Disable Flag 0 = enable A/F ratio
nonzero = disable A/F ratio Bits 8 - 1 (aa)
F129 aa Speed Governor Aux #1 Gain Status 0 = aux. #1 governor gains not in use
nonzero = aux. #1 governor gains in use Bits 8 - 1 (aa)
F44E aabb Actual Exhaust Oxygen Percent 0.01% oxygen per bit 0 to 655.03% Bits 16-9 (aa)
Bits 8-1 (bb)
F44F aabb Desired Exhaust Oxygen Percent 0.01% oxygen per bit 0 to 655.03% Bits 16-9 (aa)
Bits 8-1 (bb)
F45B aabb Desired Engine Ramp Rate speed per sec. per bit 0 to 65535 Bits 16-9 (aa)
Bits 8-1 (bb)
F510 aabb Desired Engine Idle Speed 0.5 rpm per bit 0 to 32767 rpm Bits 16-9 (aa)
Bits 8-1 (bb)
F515 aabb Engine Speed Drop Percent 0.1 % per bit 0 to 6550% Bits 16-9 (aa)
Bits 8-1 (bb)
F524 aabb Desired Full Load Exhaust Oxygen 0.01% oxygen per bit 0 to 100% Bits 16-9 (aa)
Bits 8-1 (bb)


Parts housing Mariner:

91689M
 
91689M HOUSING, OIL SEA
7004201, 7005201, 7005207
814455M
 
814455M HOUSING, OIL SEAL
7004201, 7005201, 7005207
14177M
 
14177M HOUSING, OIL SEAL
7004201, 7005201, 7005207
81176M
 
81176M HOUSING
7005207, 7005227
83584M
 
83584M HOUSING
7005201, 7005207, 7005227, 7008208, 7008226, 7008238, 7008248, 7008305
82662M
 
82662M HOUSING
7005207, 7005227, 7008238, 7008247
14213M
 
14213M HOUSING
7004201, 7005201, 7005207, 7005227, 7008204, 7008208, 7008226, 7008305, 7010209, 7015529, 7025500, 7026226, 7030205, 7030301, 7040202, 7040207PW, 7040716, 7055324, 7055524
95541M
 
95541M HOUSING ASS'Y FUEL CONNECTOR
7005201, 7005207, 7008204, 7008208, 7008226
Back to top