94545M Mariner LEAD WIRE


94545M LEAD WIRE Mariner 7010209, 7015529 LEAD
94545M LEAD WIRE Mariner
Rating:
13

Buy LEAD WIRE 94545M Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 12
 

Compatible models:

7010209   7015529   Mariner

Mariner entire parts catalog list:

7010209 1979,1983,1984,1985,1986
7015529 1979

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
626-5
Ether Injection Control Solenoid : Current Below Normal 2417-5
Ether Injection Control Solenoid : Current Below Normal The code is latched. The code is logged. Ether injection is disabled.
626-6
Ether Injection Control Solenoid : Current Above Normal 2417-6
Ether Injection Control Solenoid : Current Above Normal The code is latched. The code is logged. Ether injection is disabled.
677-5
Engine Starter Motor Relay : Current Below Normal 2727-5
Starting System #1 Relay : Current Below Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the starter motor relay.
677-6
Engine Starter Motor Relay : Current Above Normal 2727-6
Starting System #1 Relay : Current Above Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit on the starter motor relay.
2813-5
Engine Air Shutoff Command Status : Current Below Normal 3239-5
Air Shutoff Relay : Current Below Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit for the air shutoff valve relay.
2813-6
Engine Air Shutoff Command Status : Current Above Normal 3239-6
Air Shutoff Relay : Current Above Normal This code indicates that there is an electrical problem with the solenoid valve and/or circuit for the air shutoff valve relay. The applicable Electronic Control Module (ECM) monitors the current flow through the coils of the applicable components.The applicable ECM sets a diagnostic trouble code if the current flow through a coil is incorrect. These codes can be activated only when the applicable ECM is sending a command to the control valves. A -5 code indicates that the current flow through the circuit is low and there is an open in the circuit. A -6 code indicates that the current flow through the circuit is high and there is a short in the circuit.Electrical Checkouts on the Cat® Electronic Technician (ET)
Table 2
Component Electrical Checkout
Air Shutoff Solenoid Air Shutoff Override
Engine Starter Motor Relay Attempt to start the engine. once the ECM attempts to energize the solenoid, the code will become active. Refer to the application-specific schematic for the "Engine Starter Motor Relay wiring circuit."
Ether Solenoid Ether Injection Override
Illustration 1 g06344398
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Verify that the harness connector is free of debris, free of corrosion and securely connected.
B. Disconnect the solenoid from the harness.
C. Connect a jumper wire between the terminals of the harness connector for the affected coil. The coil is replaced with a short circuit.
Create a Short
Result: A -5 code became active during the electrical checkout. The ECM did not detect the jumper wire. There is an open circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -6 code is activated during the electrical checkout. The ECM detected the jumper wire. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Disconnect the solenoid from the harness.
Create an Open
Result: A -6 code became active during the electrical checkout. The ECM did not detect the open circuit. There is a short circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -5 code is activated during the electrical checkout. The ECM detected the open circuit. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).