892647A01 MULTI-METER KIT, DMT 2004 Mariner
7115F13RD, 7115F13UF, 7135V13ID, 7135V13UB, 7135V13ZB, 7225413IY, 7225413RD, 7225413ZY, 7250423IY, 7A30302LB, 7A30453VZ, 7A40302UD, 7A40302ZZ, 7A40312UZ, 7A40312ZZ, 7A40412ZZ, 7A41412LB, 7A41452IZ, 7A41452UZ, 7A51412ZZ, 7A51452IZ, 7A60412ZZ, 7A60452I
MULTI
Price: query
Rating:
Compatible models:
7115F13RD
7115F13UF
7135V13ID
7135V13UB
7135V13ZB
7225413IY
7225413RD
7225413ZY
7250423IY
7A30302LB
7A30453VZ
7A40302UD
7A40302ZZ
7A40312UZ
7A40312ZZ
7A40412ZZ
7A41412LB
7A41452IZ
7A41452UZ
7A51412ZZ
7A51452IZ
7A60412ZZ
7A60452IZ
7E41412ZB
7E51412ZB
7E51413VZ
7E60412ZB
7E60413VZ
7E60452IZ
7E60452ZB
7F042016B
7F30203LB
7F40203UD
7F40203ZZ
7F40213UZ
7F40452LB
Mariner
Mariner entire parts catalog list:
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
7135V13UB 2006
7135V13ZB 2006
7225413IY 2006
7225413RD 2004,2005,2006
- TOOLS » 892647A01
- TOOLS » 892647A01
7A30302LB 2002,2003,2004,2005
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- SPECIAL TOOLS » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
- TOOLS 1 » 892647A01
Information:
Table 1
Diagnostic Trouble Code for the Water-in-Fuel Sensor
J1939 Code CDL code Code Description
(code descriptions may vary Comments
97-3 3547-3 Water In Fuel Indicator : Voltage Above Normal The ECM detects the following conditions:
An open circuit in the Water-In-Fuel (WIF) sensor circuit.
The ECM has been powered for less than 5 seconds.
The warning lamp will stay on when the "indicator lamp self check" has been completed. The ECM will disable the function to detect water in fuel while the code is active. Water-in-Fuel Sensor OperationThe WIF sensor is a normally open sensor. During normal operation, there will be no signal sent from the WIF sensor to the ECM. If water is detected in the fuel, the sensor will send a signal to the ECM. If the signal remains constant for 45 seconds, a 97-15 (E232-1) diagnostic code will become active. If the signal remains constant for 1 hour, a 97-16 (E232-2) diagnostic code will become active. These diagnostic codes can also be caused by a short in the WIF sensor circuit.During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly inspect the connector for the WIF sensor and the P1/J1 ECM connector. Refer to Troubleshooting, "Electrical Connectors - Inspect".
C. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the WIF sensor.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness for abrasions, for pinch points, and for corrosion.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors