Information:

For this procedure, a known pressure is applied to the contactor. The pressure simulates engine oil pressure and the pressure closes the normally open contacts. To account for the contactor's hysteresis, the applied pressure must be approximately five percent greater than the setpoint. The pressure is slowly reduced while the contactor is monitored in order to determine whether the contact opens at the desired low pressure. The contactor is adjusted, if necessary.Before you perform this procedure, determine the setpoint's pressure for the specific contactor. The setpoints are listed in Operation and Maintenance Manual, SEBU7150, "Alarms and Shutoffs".
Turn OFF the monitoring system's power supply.Note: The terminals are identified on the contactor's receptacle.
Illustration 1 g00872633
Side view of a contactor's electrical connection (1) Retaining bolt (2) Receptacle (3) Plug (AA) Identification of the terminals
Unscrew retaining bolt (1) and disconnect receptacle (2) from plug (3) .
Illustration 2 g00873670
Connect a multimeter to common terminal 1 and normally open terminal 3 on plug (3). Set the multimeter to the "Ohms" scale.
Illustration 3 g00872578
(4) Isolation valve (5) Nut (6) Cap (A) Isolation valve in the position for normal operation (B) Isolation valve in the position for isolating the contactor
Turn isolation valve (4) in order to isolate the contactor from the pressure.
Slowly loosen nut (5) in order to purge the residual pressure from the contactor. Remove the nut. Connect the 1U-5230 Hand Hydraulic Pump to the port. Use a tee in the air hose for the 198-4240 Pressure Indicator Tool Gp (Digital). Loosen cap (6) .Note: If a tee is not available for the 198-4240 Pressure Indicator Tool Gp (Digital), remove the engine oil pressure line from the bottom of the contactor's mounting block. In this case, connect the 1U-5230 Hand Hydraulic Pump to the port for the engine oil pressure line. Connect the 198-4240 Pressure Indicator Tool Gp (Digital) to the port for nut (5). Turn isolation valve (4) to the position for normal operation.
Observe the ohmmeter and slowly increase the pressure to the contactor until the pressure is approximately five percent greater than the setpoint's pressure.If the resistance becomes less than 5 ohms, the contacts are closing correctly.If either of the following conditions are found, the contacts are not closing correctly:
The resistance becomes less than 5 ohms before the setpoint's pressure is exceeded.
The resistance does not become less than 5 ohms after the setpoint's pressure is exceeded.
Continue to observe the ohmmeter and slowly relieve the pressure from the contactor. Look for changing of the resistance as the setpoint's pressure is reached.If the resistance becomes greater than 20,000 ohms at the setpoint's pressure, the contacts are opening correctly. No adjustment is needed. Proceed to Step 12.If either of the following conditions are found, the contacts are not opening correctly. In either case, proceed to Step 8.
The resistance becomes greater than 20,000 ohms before the setpoint's pressure is reached.
The resistance does not become greater than 20,000 ohms when the setpoint's pressure is reached.
Illustration 4 g00872559
Adjustment dial for the contactor
Adjust the pressure to the setpoint's exact pressure. Use a 5 mm Allen wrench to turn the contactor's adjustment dial clockwise until the resistance is greater than 20,000 ohms. The contacts have opened.
Continue to apply the setpoint's exact pressure and slowly turn the contactor's adjustment dial counterclockwise until the resistance is less than 5 ohms. The contacts have closed. Next, slowly turn the adjustment dial clockwise until the resistance is greater than 20,000 ohms.The contacts have opened.
Slowly increase the pressure to the contactor until the resistance is less than 5 ohms.The hysteresis has been exceeded and the contacts have closed properly.
Continue to observe the ohmmeter and slowly relieve the pressure from the contactor. Look for changing of the resistance as the setpoint's exact pressure is reached.If the resistance becomes greater than 20,000 ohms at the setpoint's pressure, the contacts have opened correctly. No further adjustment is needed. Proceed to Step 12.If either of the following conditions are found, the contacts did not open correctly. In either case, repeat Steps 8 through 11 until the contacts open when the pressure is reduced to the setpoint's pressure.
The resistance becomes greater than 20,000 ohms before the setpoint's pressure is reached.
The resistance does not become greater than 20,000 ohms when the setpoint's pressure is reached.
Purge any residual pressure from the pressurizing pump and remove the pump from the port. Replace cap (6). Install nut (5). Turn isolation valve (4) to the position for normal operation.
Remove the ohmmeter. Connect receptacle (2) to plug (3). Secure the connection with retaining bolt (1) .


Parts nut Mariner:

82395M
 
82395M NUT
7003207, 7005207, 7005227, 7008208, 7008238, 7008248, 7015307, 7015327, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7030320, 7040202, 7040206, 7040207, 7040207PW, 7040208, 7040208P
82389M
 
82389M NUT
7002200, 7003207, 7004201, 7005201, 7005207, 7005227, 7008204, 7008208, 7008218EW, 7008226, 7008238, 7008247, 7008248, 7008305, 7008425, 7010209, 7015207, 7015307, 7015327, 7015529, 7025207PW, 7025208CW, 7028207, 7028527, 7030320, 7040202, 7040206, 7
82381M
 
82381M NUT
7004201, 7005201, 7005207, 7005227, 7008204, 7008208, 7008226, 7008238, 7008247, 7008248, 7008305, 7010209, 7015207, 7015307, 7015327, 7015529, 7025200, 7025500, 7028527, 7030200, 7040202, 7040206, 7040207, 7040208, 7040328, 7040507, 7040706, 7040716
82378M
 
82378M NUT, REAR APPLIQUE ATTACHING...
7008204, 7008208, 7008226, 7008238, 7008247, 7015207, 7015307, 7015327, 7020201, 7025200, 7025207NW, 7025207PW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7040202, 7040206, 7040207, 7040208, 7040328, 7040507, 7040716, 7048207, 704
82379M
 
82379M NUT
7010209, 7015207, 7015307, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030320, 7040208, 7040328, 7040706, 7040716
81782M
 
81782M NUT
7015307, 7015327
82537M
 
82537M NUT, RETAINER SCREW
7008208, 7008218EW, 7008238, 7008248, 7008305, 7008425, 7010209, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7030320, 7040202, 7040206, 7040207, 7040207PW, 704020
43102M
 
43102M NUT
7015327
Back to top