Table 1
Event Code
Description Conditions which Activate the Code System Response
E401 (1) Cylinder #1 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E401 (3) Cylinder #1 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E421 (3) Cylinder #1 Detonation Shutdown
E402 (1) Cylinder #2 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E402 (3) Cylinder #2 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E422 (3) Cylinder #2 Detonation Shutdown
E403 (1) Cylinder #3 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E403 (3) Cylinder #3 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E423 (3) Cylinder #3 Detonation Shutdown
E404 (1) Cylinder #4 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E404 (3) Cylinder #4 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E424 (3) Cylinder #4 Detonation Shutdown
E405 (1) Cylinder #5 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E405 (3) Cylinder #5 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E425 (3) Cylinder #5 Detonation Shutdown
E406 (1) Cylinder #6 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E406 (3) Cylinder #6 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E426 (3) Cylinder #6 Detonation Shutdown
E407 (1) Cylinder #7 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E407 (3) Cylinder #7 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E427 (3) Cylinder #7 Detonation Shutdown
E408 (1) Cylinder #8 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E408 (3) Cylinder #8 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E428 (3) Cylinder #8 Detonation Shutdown
E409 (1) Cylinder #9 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E409 (3) Cylinder #9 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E429 (3) Cylinder #9 Detonation Shutdown
E410 (1) Cylinder #10 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E410 (3) Cylinder #10 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E430 (3) Cylinder #10 Detonation Shutdown
E411 (1) Cylinder #11 Detonation The level of detonation has exceeded the trip point. The alarm output is activated. Engine timing is retarded in order to reduce detonation. The code is logged.
E411 (3) Cylinder #11 Detonation Shutdown The level of detonation has exceeded the trip point for engine shutdown. Maximum retardation of the timing was unable to control the detonation adequately during the number of ignition sparks that are allowed. The shutdown output is activated. The code is logged. The engine is shut down.
E431 (3) Cylinder #11


Parts owners Mariner:

814319950
821732950
816763950
821733950
 
821733950 OWNERS GUIDE (55) (GRAY)
7050412YD, 7060412ET
826596950
 
826596950 OWNERS GUIDE (JET 45)
7050412YD, 7060412ET
10171970
 
10171970 OWNERS GUIDE
7050302ED, 7060412ET
10173970
 
10173970 OWNERS GUIDE
7050302ED, 7060412ET
10176970
 
10176970 OWNERS GUIDE
7050302ED, 7060412ET
Back to top