Information:


Table 1
J1939 Code and Description CDL Code and Description System Response
3551-5
Engine Oil Priming State : Current Below Normal 338-5
Engine Pre-Lube Pump Relay : Current Below Normal The Electronic Control Module (ECM) detects an open in the circuit for the prelubrication relay.
The ECM detects a short to battery voltage in the circuit for the prelubrication relay.
The code is logged.
3551-6
Engine Oil Priming State : Current Above Normal 338-6
Engine Pre-Lube Pump Relay : Current Above Normal The ECM detects a short in the circuit for the prelubrication relay.
The code is logged. The ECM can lubricate the engine before cranking begins. This engine prelubrication is used to increase the life of certain engine parts by lubricating these parts before the starting motor is engaged.There are several configuration parameters that define the operation of the prelubrication system. Prior to troubleshooting problems that are associated with the prelubrication system, check the settings of these parameters. Be sure that you understand the proper operation of the system.The charge pressure status of the prelubrication system may be communicated to several different controllers that are on the application. Depending on the status that is communicated there could be an effect on the engine starting. The following status indicators are communicated over the data link:
"Prelube OFF" or "Prelube disabled"
"Prelube waiting for oil"
"Prelube waiting to fill"
"Perlube ready to start"
"Prelube failed"
"Prelube ready to start"
"Continuous prelube"Some of these status indicators report the parameter settings of the prelubrication system. The ECM determines the charge pressure status via the engine oil pressure sensor.The prelubrication system is activated at ECM powerup. The ECM prevents the starting motor from engaging while the pump builds pressure in the lubrication system.Also, a manual prelube switch may be wired to P1-60 terminal at the primary ECM connector. When this ECM input is grounded, the ECM will activate the prelubrication relay. Refer to Troubleshooting, "Switch Circuits - Test" for information related to troubleshooting this switch circuit.An override for the prelubrication system is available in Caterpillar Electronic Technician (ET). The override allows the technician to activate the prelubrication system for service and testing. The test is functional only when the engine speed is zero rpm. The test is accessed by selecting the following menus on Cat ET:
"Diagnostics"
"Diagnostic Tests"
"Override Parameters"
Illustration 1 g02784357
Schematic for the prelubrication system if equipped with an A4 ECM
Illustration 2 g06320888
Schematic for the prelubrication system if equipped with an A5 ECM
Illustration 3 g03676535
Location of the prelubrication pump and the prelubrication solenoid (engine view)
(1) Prelubrication pump
(2) Prelube solenoid
Illustration 4 g02579136
Location of the ECM connectors (front side engine view)
(3) ECM
(4) J2/P2 ECM connector
(5) J1/P1 ECM connector
(6) Connector for the left rail
Table 2
Troubleshooting Test Steps Values Results
1. Inspect the Electrical Connectors and the Wiring
A. Remove the electrical power from the ECM.
B. Thoroughly inspect connectors (4), (5), and (6). Also, thoroughly inspect the other connectors for the prelubrication relay that are in the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the proper procedure for inspecting the connectors and the wiring.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors and the other connections that are associated with the circuit.
D. Check the allen head screw for each of the ECM connectors for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
E. Check the harness and the wiring for abrasion and for pinch points.
Connectors
Results: The connectors and wiring appear to be OK.
Proceed to Test Step 2
Results: There is a problem in the connectors and/or wiring.
Repair The connectors or wiring and/or replace the connectors or wiring. Ensure that all the seals are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminates the problem.
2. Check for Active Diagnostic Codes
A. Connect Cat ET to the service tool connector.
B. Restore the electrical power to the ECM.
C. Monitor the active diagnostic code screen on Cat ET. Check the prelubrication system for an active diagnostic code.
Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
D. Select diagnostic tests from Cat ET.
E. Select the "Override Parameters" screen on Cat ET.
F. Activate the override for the prelubrication system.
G. Monitor the active diagnostic code screen on Cat ET. Check the prelubrication system for an active diagnostic code.
Note: Wait at least 30 seconds in order for the diagnostic code to become active.
H. Disable the override for the prelubrication system.
Active codes
Results: No diagnostic codes are active, but a problem is suspected in the prelubrication system.
Proceed to Test Step 6
Results: A -6 diagnostic code is active at this time. A short is detected in the circuit for the prelubrication relay.
Proceed to Test Step 3
Results: A -5 diagnostic code is active at this time. An open is detected in the circuit for the prelubrication relay.
Proceed to Test Step 4
3. Create an Open Circuit at the Control Circuit of the Prelubrication Relay
A. Remove the electrical power from the ECM.
B. Disconnect the control inputs from the blade terminals at the prelubrication relay.
C. Restore the electrical power to the ECM.
D. Monitor the active diagnostic code screen on Cat ET. Check the prelubrication system for an active diagnostic code.
Note. Wait at least 30 seconds in order for the diagnostic codes to become active.
E. Select diagnostic tests from Cat ET.
F. Select the "Override Parameters" screen on Cat ET.
G. Activate the override for the prelubrication system.
H. Monitor the active diagnostic code screen on Cat ET. Check for an active diagnostic code for the prelubrication system.
Note: Wait at least 30 seconds in order for the diagnostic code to become active.
I. Remove the electrical power from the ECM.
Open Circuit
Results: A -6 diagnostic code was acti


Parts pin Mariner:

16119
 
16119 PIN
7002201DK, 7002201HB, 7002201SK, 7002201UB, 7003201BK, 7004201HB, 7004201UB, 7004211SK, 7006201MK, 7006201UK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7040203KL, 7040203UL, 7A25203U
16179
 
16179 PIN
7004201HB, 7004201UB, 7004211SK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7040203KL, 7040203UL, 7A25203UK, 7A25213UL, 7A25302UL, 7A3G312UK, 7F042016B, 7F04201JB, 7F08201TB, 7F15311Z
16085
 
16085 PIN
7004201HB, 7004201UB, 7004211SK, 7015203KL, 7015203UL, 7F042016B, 7F04201JB
16179 1
 
16179 1 PIN
7002201HB, 7002201UB, 7003201BK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7F02201ZK
16256 1
PIN
16256 1 PIN
7015203KL, 7015203UL, 7040203KL, 7040203UL, 7F08201TB, 7F15311ZK
803680
 
803680 PIN, Piston
7015203KL, 7015203UL
825713001
 
825713001 PIN, Piston
7015203KL, 7015203UL, 7F02201ZK, 7F08201TB
16085 1
 
16085 1 PIN
7015203KL, 7015203UL, 7F08201TB, 7F15311ZK
Back to top