855237 Mariner PLUG


855237 PLUG Mariner 7F08203HF, 7F08261DF, 7F13203UB PLUG
855237 PLUG Mariner
Rating:
103

Buy PLUG 855237 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$35.61
 

01-05-2024
0.14 Kilograms
LU: Amazon Global Store
Brodit 855237 Bracket Proclip
Brodit Proclip is a mounting bracket that you interlocking fixed in a position clearly defined the dashboard of your car || Production is tailored to each brand, model and year of the vehicle || Note: also be purchased a holder to install the device and thus achieve the full support
Number on catalog scheme: 10
 

Compatible models:

Mariner entire parts catalog list:

7F08203HF 1999
7F08261DF 1995,1996,1997,1998
7F13203UB 2006

Information:


Table 1
Diagnostic Codes Table
CDL Code and Description Comments
94–3
Fuel Delivery Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
94–4
Fuel Delivery Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
100-3
Engine Oil Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
100-4
Engine Oil Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
101-3
Crankcase Air Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
101-4
Crankcase Air Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
274-3
Atmospheric Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
274-4
Atmospheric Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
460-3
Fuel Pressure Sensor - After Fuel Filter : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
460-4
Fuel Pressure Sensor - After Fuel Filter : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1785-3
Intake Manifold Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1785-4
Intake Manifold Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1835-3
Auxiliary Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1835-4
Auxiliary Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
1924-3
Engine Intake Valve Actuation System Oil Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged. The value of the parameter is set to a gauge pressure.
1924-4
Engine Intake Valve Actuation System Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range. The code is logged. The value of the parameter is set to a gauge pressure.
Illustration 1 g06164330Probable Causes
Codes
Short circuit
Open circuit
Supply voltage
Wiring
DPF components
Electrical connectorsRecommended Actions
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Establish communication between Cat® Electronic Technician (ET) and the ECM . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Turn the keyswitch to ON.
C. Look for "-3", or "-4" active or logged codes.
Codes
Result: A -3 diagnostic code is active.
Proceed to Test Step 2.
Result: A -4 diagnostic code is active.
Proceed to Test Step 3.
2. Create a Short at the Sensor Connector
A. Use a test lamp to create a short between terminal 3 (signal) and terminal 2 (sensor return) at the sensor connector.
B. Turn the keyswitch to ON.
C. Monitor the diagnostic codes on Cat ET. Check for an active -4 diagnostic code for the suspect sensor.
D. Turn the keyswitch to OFF.
Short circuit
Result: A -4 diagnostic code does not become active for the suspect sensor.
Proceed to Test Step 4.
Result: A -4 diagnostic code became active after creating the short at the sensor connector. The wiring is OK.
Repair: Replace the sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Create an Open at the Suspect Sensor Connector
A. Turn the keyswitch to OFF.
B. Disconnect the sensor connector of the suspect sensor with the active -4 diagnostic code.
C. Turn the keyswitch to ON.
D. Monitor the diagnostic codes on Cat ET. Check for an active -3 diagnostic code for the suspect sensor.
E. Turn the keyswitch to OFF.
Open circuit
Result: A -3 diagnostic code did not become active after disconnecting the sensor.
Proceed to Test Step 4.
Result: A -3 diagnostic code became active after disconnecting the sensor. The wiring is OK.
Repair: Replace the sensor.
If the problem is not resolved, proceed to Test Step 4.
4. Check the 5 VDC Supply Voltage at the Sensor Connector
A. Turn the keyswitch to ON.
B. Measure the voltage between pin 1 and pin 2 at the suspect sensor.
5.0 0.2 VDC
Result: The supply voltage is OK.
Repair: Connect the sensor.
Proceed to Test Step 5
Result: The supply voltage is NOT OK. There is a short in the harness to the battery.
Repair: Repair the wiring


Parts plug Mariner:

48323
 
48323 PLUG, CONTROL SHAFT
7001200, 7225413IY, 7225413LD, 7225413RD, 7225413ZY, 7250423IY, 7B25201GF, 7F10203HD, 7F13203UB, 7F25203LB, 7F30203LB, 7F40203UD, 7F40203ZZ, 7F40213UZ, 7F40452KD, 7F40452LB, 7F41452KB, 7F41452KD, 7F75413ZD
824473
 
824473 PLUG-WARNING ALARM
7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7F08203HF, 7F08261DF
827466M
 
827466M PLUG-MAIN NOZZLE
7F08203HF, 7F08261DF
825437
 
825437 PLUG
7F08203HF, 7F08261DF
825490
PLUG-OIL
825490 PLUG-OIL
7F08203HF, 7F08261DF, 7F15201GD, 7F25201GD, 7F41452KD, 7F50352HD, 7F50412DD
826037
PLUG
826037 PLUG
7F08203HF, 7F08261DF, 7F10203HD, 7F13203UB, 7F15201GD
855937
 
855937 PLUG
7F10203HD, 7F13203UB, 7F15201GD
822513002
 
822513002 PLUG
7031312TB, 7F10203HD, 7F13203UB
Back to top