812966A11 Mariner W/P REPAIR KIT


812966A11 W/P REPAIR KIT Mariner 7050412YD, 7055207HB, 7055207TF, 7060412ET, 7F40452KD, 7F40452LB, 7F41452KB, 7F41452KD W
812966A11 W/P REPAIR KIT Mariner
Rating:
13

Buy W/P REPAIR KIT 812966A11 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$48.99
 

04-09-2024

CN: JAETHB Auto Part
Water Pump Repair Kit for Mercury Mariner 46-812966A12 812966A11 812966A4 812966A5 14334A1 14334A2 14334A3 Outboard 30 35 40 50 60 75 HP EFI JET SeaPro Carb Formula BIGFOOT 3/4-Cyl 4-Stroke
JAETHB [Tips] : We will show more detailed information about the product on the details page below to ensure that we can help you to buy the correct replacement part || [Note] : In order to prevent purchasing the wrong unsuitable part, which could result in wasted time, you need to determine suitability by using the information on the engine nameplate || [Adaptation] : Part of the Mercury Mariner (30 35 40 50 60 75HP) , 4-Stroke EFI JET SeaPro Carb Formula BIGFOOT 3/4-Cyl. Engine || [OEM#] : Replacing part numbers For Mercury Mariner 46-812966A12 , 812966A11 , 812966A4 , 812966A5 , 14334A1 , 14334A2 , 14334A3 || [Quality] : Original level of quality and durability, the impellers are manufactured from high quality rubber and will not be damaged even after long periods of immersion in salt water
$84.00
 

19-08-2024
1.3558[0.61] Pounds
CN: MAXCOOLE
Compatible with 46-812966A12 Boat Engine Pump Repair Kit
ノーブランド品 46-812966A12, 812966A11, 812966A10, 812966A6, 812966A5, 812966A4, 14334A3, 14334A2, 14334A1 Mercury Mariner Boat Engine Water Suitable for pump repair kit Outboard Motors 2 4Stroke 30HP, 40HP, 50HP, 55HP, 60HP, 70HP, 75HP Motor Replacement Parts || Weight: 22.1 oz (615 g). Material: Neoprene rubber & top quality metal alloy. Please refer to the picture || Application: This 46-812966A12 repair kit applies outboard motors 2-4Stroke 30HP, 40HP, 50HP, 55HP, 60HP, 70HP, 75HP motors || ️ Applicable Applications Replacement OEM P/N #: Mercury Mariner: 46-812966A12,812966A11,812966A10, 812966A6, 812966A5, 812966A4, 14334A3, 14334A2, 14334 A1
$63.69

11-01-2025

CN: Marine Parts Manufac
Boat Engine 46-812966A4 812966A5 812966A6 812966A10 812966A11 812966A12 46-46514 Water Pump Impeller Repair Kits w/Housing for Mercury Mariner Force Quicksilver Outboard 30HP 40HP 50HP 55HP 60HP 70HP
SouthMarine Fit Part Number: 46-812966A4 812966A5 812966A6 812966A10 812966A11 812966A12 46-46514 || The kit includes:1pc Impeller 47-19453T,1pc Plate 19700A 2,1pc Housing 14334A 3,1pc Base 46-812966A 7,1pc Coupler/Guide tube 859770, 859770 1, 893857,2pc Washer 12-858234,1pc Gasket Upper 27-822189,1pc Gasket Lower 27-19701,1pc Impeller Key, 1pc O-Ring || Fit Engine: 30HP 40HP 50HP 55HP 60HP 70HP 75HP || Installation Instructions: Lubricate with silicone grease(Not included), glycerin or dish soap when installing. Designed for durability to provide higher flow rates and cooling flow to protect your engine, This impeller kit makes repair and maintenance of water pumps easy. || If you are unsure, please provide your engine serial number.
Number on catalog scheme: -
 

Mariner entire parts catalog list:

7050412YD 1991,1992,1993,1994,1995,1996
7055207HB 1999,2000,2001,2002,2003,2004
7055207TF 2005,2006
7060412ET 1996
7F40452KD 2001
7F40452LB 2002
7F41452KB 2001,2002
7F41452KD 2001

Information:


Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
41-3 8 Volt DC Supply : Voltage Above Normal The digital sensor supply voltage is above normal for one second. The code is logged.
All sensors are set to default values.
41-4 8 Volt DC Supply : Voltage Below Normal The digital sensor supply voltage is below normal for one second.
262-3 5 Volt Sensor DC Power Supply : Voltage Above Normal The analog sensor supply voltage is above normal for one second. The code is logged.
All sensors are set to default values.
262-4 5 Volt Sensor DC Power Supply : Voltage Below Normal The analog sensor supply voltage is below normal for one second.
2131-3 5 Volt Sensor DC Power Supply #2 : Voltage Above Normal The analog sensor supply voltage is above normal for one second The code is logged.
Engine power may be derated.
2131-4 5 Volt Sensor DC Power Supply #2 : Voltage Below Normal The analog sensor supply voltage is below normal for one second. Note: The 262 diagnostic codes indicate a problem with the 5 V power supply on the J2 ECM connector. The 2131 diagnostic codes indicate a problem with the 5 V power supply on the J1 ECM connector.System OperationThe Electronic Control Module (ECM) supplies a regulated voltage of 5.0 0.2 VDC to the following sensors:
Fuel pressure sensor
Engine oil pressure sensor
Atmospheric pressure sensor
Turbocharger inlet pressure sensor
Intake manifold pressure sensor
Crankcase pressure sensorThe ECM supplies a regulated voltage of 8.0 0.4 VDC to the following sensor:
Sensor for the left turbocharger turbine inlet temperature
Sensor for the right turbocharger turbine inlet temperatureThe supply voltage for the sensors is routed from the ECM to terminal A of each sensor connector. The sensor return for the sensors is routed from the ECM to terminal B of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.Note: The sensors are not protected from overvoltage. A short from the supply line to the +Battery may damage the sensors. If any of the 3 diagnostic codes are active, it is possible that a sensor has been damaged. Repair the sensor supply and check for any active sensor diagnostic codes in order to determine if a sensor has failed.
Illustration 1 g02722071
Typical schematic
Illustration 2 g02791987
Typical schematic 8V
Illustration 3 g02743076
Location of ECM connectors
(1) J1 ECM connector
(2) J2 ECM connector
Illustration 4 g02792225
P1 ECM connector
(P1-2) 5 V Sensor supply
(P1-3) Analog sensor return
Illustration 5 g02792227
P2 ECM connector
(P2-17) Sensor return
(P2-29) 5 V Sensor supply
(P2-30) Sensor return
(P2-54) Sensor return
(P2-72) 5 V Sensor supply
(P2-80) 5 V Sensor supply
(P2-81) 5 V Sensor supply
(P2-82) 5 V Sensor supply
(P2-83) Sensor return
(P2-92) Sensor return
Illustration 6 g01159881
Sensor connector
(A) 5 V or 8 V sensor supply
(B) Sensor return
(C) Signal Test Step 1. INSPECT ELECTRICAL CONNECTORS AND WIRING
Remove electrical power from the ECM.
Thoroughly inspect the J1/P1 ECM connector and the J2/P2 ECM connector. Inspect all of the connectors that are associated with the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and wiring for abrasion and for pinch points from the sensors back to the ECM. Expected Result:All connectors, pins, and sockets are coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and connectors appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.Verify that the repair eliminates the problem.STOPTest Step 2. CHECK FOR ACTIVE DIAGNOSTIC CODES
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Restore electrical power to the ECM.
Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes. Look for the following diagnostic codes:
41-3
41-4
262-3
262-4
2131-3
2131-4 Note: Wait at least 30 seconds in order for the diagnostic codes to become active.Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic code is active.Repair: The problem is no longer present. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - A 262-3, 262-4, 2131-3 or 2131-4 diagnostic code is active at this time. Proceed to Test Step 3.
Not OK - A 41-3 or 41-4 diagnostic code is active at this time. Proceed to Test Step 5.Test Step 3. DISCONNECT THE 5 VOLT SENSORS WHILE YOU MONITOR THE ACTIVE DIAGNOSTIC CODES
Use this procedure for any 262 diagnostic codes.
Monitor the active diagnostic code screen on Cat ET while you disconnect each 5 Volt sensor at the sensor connector. Check for an active 262-3 code or an active 262-4 code. Note:


Parts w Mariner:

814669A 2
W/P SEAL KIT
814669A 2 W/P SEAL KIT
7050302ED, 7050412YD, 7055207GD, 7055207HB, 7055207TF, 7060412ET, 7A30453VZ, 7A40302UD, 7A40302ZZ, 7A40312UZ, 7A40312ZZ, 7A40412ZZ, 7A41412LB, 7A41452IZ, 7A41452UZ, 7A51412ZZ, 7A51452IZ, 7A60412ZZ, 7A60452IZ, 7E41412ZB, 7E51412ZB, 7E51413VZ, 7E60412Z
821354A 2
W/P REPAIR KIT
821354A 2 W/P REPAIR KIT
7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7F25201GD, 7F25203JB, 7F30203HD, 7F40452KD, 7F41452KD, 7F50352HD
812966A 6
 
812966A 6 W/P REPAIR KIT
7050302ED, 7060412ET
Back to top