Illustration 1 g00479965
System Schematic For Starting Motor Relay (SMR)The GSC+ uses the starting motor relay (SMR) to activate the starting motor magnetic switches ("SMMS1" and "SMMS2") and the battery charger. The SMR is located within the relay module. "SMMS1" and "SMMS2" are located on the subpanel within the control panel.Note: Whenever the GSC+ activates the SMR, "K4" is shown on the lower display. "K4" is also shown on the lower display when the GSC+ attempts to activate the crank terminate relay. When the SMR is not activated, "K4" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the SMR.The following response is the system response to this fault while the SMR is activated:
If a CID 444 occurs, then the engine stops cranking.The following response is the system response to this fault while the SMR is not activated:
If a CID 444 occurs, then the engine cannot crank or the engine cannot start. If the engine is already running, then the engine continues to run.The GSC+ treats a CID 444 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 444 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 444 FMI 12 is showing as a active fault or an inactive fault. Results:
OK: A CID 444 FMI 12 has not occurred. The fault is NOT active and the fault is NOT inactive. STOP.
NOT OK: A CID 444 FMI 12is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK: Reassemble the relay module to the GSC+. Proceed to 3.
NOT OK: Replace the connector clamp if the clamp is missing. If the cable is damaged, replace the GSC+. STOP.
Perform a functional check for the SMR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-18 of the relay module.
Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-18 to RM-6. Resistance should be greater than 5000 ohms.
Prepare to measure the resistance from RM-18 to RM-6 of the relay module.
Turn the ECS to the START position. Quickly measure the resistance before the starting motor relay deactivates because of the crank time. Resistance should be less than 5 ohms.Expected Result: For 3.d, the resistance should be greater than 5000 ohms. For 3.f, the resistance should be less than 5 ohms.Results:
OK: There was probably a poor electrical connection and performing this procedure corrected the poor connection. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts rivet Mariner:

81906M
 
81906M RIVET
7005207, 7005227, 7008238, 7008247
81905M
 
81905M RIVET
7005207, 7005227, 7008238, 7008247, 7015207, 7015307, 7015327
83140M
 
83140M RIVET
7004201, 7005201, 7005207, 7008204, 7008208, 7008226, 7010209, 7015307, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7030320
810951M
 
810951M RIVET
7004201, 7005201, 7005207
20426
 
20426 RIVET
7004201, 7005201, 7005207, 7005227, 7008204, 7008208, 7008226, 7008238, 7008247, 7008248, 7008305, 7010209, 7015207, 7015307, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7040202, 70402
81907M
 
81907M RIVET
7004201, 7005201, 7005207, 7008204, 7008208, 7008226, 7008238, 7008247, 7010209, 7015207, 7015307, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028207, 7028527, 7030200, 7030205, 7030301, 7030320, 7040202, 7
81908M
 
81908M RIVET, SWIVEL BRACKET COVER...
7008208, 7008238, 7008247, 7008248, 7008305
83599M
 
83599M RIVET
7008208, 7008238, 7008248, 7008305, 7040202, 7040206, 7040207, 7040208, 7040328, 7040507, 7040716
Back to top