59072 Mariner SCREEN, FILTER - INLET


59072 SCREEN, FILTER - INLET Mariner 7070509, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 7135826, 7140528, 7140629, 7150629, 7175629, 7200620 SCREEN
59072 SCREEN, FILTER - INLET Mariner
Rating:
33

Buy SCREEN, FILTER - INLET 59072 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 26
 

Mariner entire parts catalog list:

7070509 1979
7090520 1980
7090524 1984,1985,1986,1987,1988
7090529 1979
7115520 1980
7115528 1978
7115529 1979
7135826 1986,1987,1988
7140528 1978,1979
7140629 1979
7150629 1979,1980,1982,1984,1985
7175629 1979,1980,1985,1986,1988
7200620 1980,1982,1983,1984,1985,1986,1988

Information:


Table 1
Specifications for 320-3061 Pressure Sensor    
Callout     Part Number     Part Name     Specification Description    
3     320-3061     Pressure Sensor     Torque to...................
10 N m (89 lb in)    
7     320-3061     Pressure Sensor     Torque to...................
10 N m (89 lb in)    
9     348-4637     Bolt     Torque to...................
12 N m (106lb in)    
12     369-8898     Pipe As     Torque to...................
20 N m (177 lb in)    
13     361-3450     Union     Torque to...................
30 N m (266 lb in)    
15     361-3450     Union     Torque to...................
30 N m (266 lb in)    
18     369-8883     Pipe As     Torque to...................
20 N m (177 lb in)    Removal Procedure
Illustration 1 g02514417
Slide locking tab (2) in to the unlocked position. Disconnect harness assembly (1) from inlet pressure sensor (3) .
Use a deep socket in order to remove inlet pressure sensor (3) .
Remove O-ring seal (4) from inlet pressure sensor (3) .
Slide locking tab (6) in to the unlocked position. Disconnect harness assembly (5) from outlet pressure sensor (7) .
Use a deep socket in order to remove outlet pressure sensor (7) .
Remove O-ring seal (8) from outlet pressure sensor (7) .
Illustration 2 g02514418
If necessary, follow Step 7.a through Step 7.j in order to remove the bracket assembly and the tube assemblies from NRS Induction mixer.
Cut cable strap from the harness assembly for the pressure sensors. Position the harness assembly away from bracket assembly (10) and NRS Induction mixer.
Use a suitable tool in order to hold manifold (11). Loosen tube assembly (12) at both ends.
Use a suitable tool in order to hold manifold (17). Loosen tube assembly (18) at manifold (17) .
Remove Torx screws (9) from bracket (10) .
Remove the assembly of bracket (10) and disconnect from tube assembly (12) and tube assembly (18) from the assembly of the bracket.
Disconnect tube assembly (12) from connection (15) .
Loosen tube assembly (18) from connection (13) (not shown). Disconnect tube assembly (18) from connection (13) (not shown).
If necessary, remove connection (13) (not shown) and connection (15) from the NRS Induction mixer.
Remove O-ring seal (14) (not shown) from connection (13) (not shown).
Remove O-ring seal (16) (not shown) from connection (15) .Installation Procedure
Ensure that the wiring harness assembly is correctly routed and the cable straps are not over tightened. Over tightening of the cable straps will damage the wiring harness and the convoluting.
Ensure that all components are clean and free from wear and damage. If necessary, replace any components that are worn or damaged.
Illustration 3 g02514418
If necessary, follow Step 2.a through Step 2.n in order to install the bracket assembly and the tube assemblies to NRS Induction mixer.
Install a new O-ring seal (14) (not shown) to connection (13) (not shown).
Install a new O-ring seal (16) (not shown) to connection (15) .
Install connection (13) and connection (15) (not shown) to NRS Induction mixer. Tighten connections to a torque of 30 N m (266 lb in).
Installation of tube assembly (18) and bracket (10) is required in order to position the tube assembly. Loosely install tube assembly (18) to connection (13) on the NRS Induction mixer.
Position the assembly of bracket (10) onto the NRS Induction mixer. Connect tube assembly (18) to manifold (17) .
Install Torx screws (9) to bracket (10) finger tight.
Tighten tube assembly (18) at connection (13). Tighten tube assembly to a torque of 20 N m (177 lb in).
Loosen tube assembly (18) at manifold (17). Remove Torx screws (9) from bracket (10) and remove the bracket.
Loosely install tube assembly (12) to connection (15) on the NRS Induction mixer. Hand tighten tube assembly (12) .
Position bracket assembly (10) onto the NRS Induction mixer and connect tube assembly (12) and tube assembly (18) hand tighten the tube assemblies.
Install Torx screws (9) to bracket (10) .
Tighten Torx screws (9) to a torque of 12 N m (106lb in).
Use a suitable tool in order to hold manifold (11). Tighten tube assembly (12) to a torque of 20 N m (177 lb in).
Use a suitable tool in order to hold manifold (17). Tighten tube assembly (18) to a torque of 20 N m (177 lb in).
Illustration 4 g02514417
Install a new O-ring seal (8) to outlet pressure sensor (7) .Note: Do not lubricate the O-ring seal.
Use a deep socket in order to install outlet pressure sensor (7). Tighten the outlet pressure sensor to a torque of 10 N m (89 lb in).
Connect harness assembly (5) to outlet pressure sensor (7). Slide locking tab (6) in to the locked position.


Parts screen Mariner:

57819
 
57819 SCREEN ASSEMBLY, FILTER - CARBURETOR
7090520, 7090529, 7115520, 7115528, 7115529, 7140528, 7140629
72849A 1
 
72849A 1 SCREEN ASSEMBLY, PORT AND STARBOARD
70404119D, 7045217, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520
Back to top