69034 Mariner SCREW, END CAP MOUNTING


69034 SCREW, END CAP MOUNTING Mariner 7002201DK, 7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520, 7075524, 7080629, 7090520, 7090524, 7115520, 7115528, 7115529, 71354120D, 7135412AD, 7135412ED, 7135412HD, 7135417PD, 7135473GD, 7135473HD, 7135826, 7140528, 7140629, 7150413ED, 71504 SCREW
69034 SCREW, END CAP MOUNTING Mariner
Rating:
98

Buy SCREW, END CAP MOUNTING 69034 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 17
 

Mariner entire parts catalog list:

7002201DK 1995
7050716 1986
7050717 1987,1988,1989,1990
7060312PC 1989
7060524 1984,1985,1986,1989,1990
7070509 1979
7070520 1980,1982,1983
7075524 1984,1985,1986
7080629 1979,1980
7090520 1980
7090524 1984,1985,1986,1987,1988
7115520 1980
7115528 1978
7115529 1979
71354120D 1990,1991
7135412AD 1992,1993,1994,1995
7135412ED 1996,1997,1998
7135412HD 1999
7135417PD 1989
7135473GD 1998
7135473HD 1999
7135826 1986,1987,1988
7140528 1978,1979
7140629 1979
7150413ED 1996,1997,1998
7150413HD 1999
7150453ND 1988
7150453PD 1989,1990
7150629 1979,1980,1982,1984,1985
7175412PD 1989
7175413AD 1992,1993,1994,1995
7175413PD 1989,1990
7175413YD 1991
7175423HD 1999
7175629 1979,1980,1985,1986,1988
7200412PD 1989,1990
7200620 1980,1982,1983,1984,1985,1986,1988
7220727 1987,1988

Information:


Illustration 1 g00829791
Schematic
Illustration 2 g01007607
P2 ECM connector
Illustration 3 g01007609
P1 ECM connector
Illustration 4 g00810608
Sensor connectorTest Step 1. Disconnect the ECM Connectors
Turn the keyswitch to the OFF position.
Connect the Caterpillar Electronic Technician (Cat ET) to the service tool connector.
Disconnect the P1 ECM connector and the P2 ECM connector from the ECM.
Check the connectors for corrosion and moisture.
Connect a 140-2266 Cable (Seventy-Pin Breakout) at the J1/P1 ECM connector.
Turn the keyswitch to the ON position.
Check for active diagnostic codes on Cat ET.Note: An open circuit diagnostic code should be active for all of the engine pressure sensors.Expected Result:The 5 volt diagnostic codes are not active. An open circuit diagnostic code is active for all of the engine pressure sensors.Results:
OK - The 5 volt diagnostic codes are not active.Repair: Reconnect the P2 ECM connector. Remove the breakout T. Reconnect the P1 ECM connector. Proceed to Test Step 2.
Not OK - The 5 volt diagnostic codes are still active.Repair: Connect a test ECM.If the test ECM fixes the problem, reconnect the suspect ECM.If the problem returns, permanently install the new ECM.Verify that the repair eliminates the problem.STOPTest Step 2. Disconnect the Sensors
Turn the keyswitch to the ON position.
Monitor the active diagnostic code screen on Cat ET.
Disconnect the pressure sensors one at a time. Wait for 30 seconds after each pressure sensor is disconnected.Note: The 5 volt diagnostic code will become inactive if a pressure sensor is the cause of the 5 volt diagnostic code.
Ensure that all of the pressure sensors are disconnected.Expected Result:The 5 volt diagnostic code is still active when all of the pressure sensors are disconnected.Results:
OK - The 5 volt diagnostic code is still active.Repair: Leave all of the pressure sensors disconnected. Proceed to Test Step 4.
Not OK - The 5 volt diagnostic code disappears when the pressure sensors are disconnected. Repair: Reconnect all of the pressure sensors except the suspect sensor. Proceed to Test Step 3.Test Step 3. Check the Signal Wire
Turn the keyswitch to the ON position.Note: The suspect sensor should be disconnected.
Measure the voltage between terminal C (Signal) and terminal B (Common) of the connector for the suspect sensor on the engine harness.Expected Result:The voltage is less than 7.0 VDC.Results:
OK - The voltage is less than 7.0 VDC.Repair: Temporarily connect a new sensor.If the problem is resolved with the new sensor, reconnect the suspect sensor.If the problem returns, replace the suspect sensor.Verify that the repair eliminates the problem.STOP
Not OK - The voltage is greater than 7.0 VDC.Repair: Inspect the signal wire for a short circuit to a voltage source.Repair the signal wire or replace the signal wire.Verify that the repair eliminates the problem.STOPTest Step 4. Determine the Condition that is Present
Turn the keyswitch to the ON position.
Access the active diagnostic code screen on Cat ET.Expected Result:262-03 or 262-04 is active.Results:
262-03 - Proceed to Test Step 5.
262-04 - Proceed to Test Step 7.Test Step 5. Measure the 5 Volt Supply to the Sensor
Turn the keyswitch to the ON position.Note: All of the pressure sensors should be disconnected.
Measure the voltage between terminal A (+5V) and chassis ground for each pressure sensor.Expected Result:The voltage is 5.0 0.16 VDC.Results:
OK - The 5 volt supply is within the range. Proceed to Test Step 6.
Not OK - The voltage is greater than 5.16 volts.Repair: Check the 5 volt supply wire for a short to a higher voltage source.Repair the 5 volt supply wire or replace the 5 volt supply wire.Verify that the repair eliminates the problem.STOPTest Step 6. Check the Common Wire
Turn the keyswitch to the ON position.
Measure the voltage between terminal A (+5V) and terminal B (Common) on all of the pressure sensors.
While the voltage is monitored, perform a 45 N (10 lb) pull test on the common wires for the 5 volt supply.
P2:3 (Common)
P1:3 (Common)Expected Result:The voltage is 5.0 0.16 VDC.Results:
OK - The voltage is within the range.Repair: If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The voltage is not within the range.Repair: Inspect the common wire for an open circuit.Repair the common wire or replace the common wire.Verify that the repair eliminates the problem.STOPTest Step 7. Check the Resistance of the Harness
Turn the keyswitch to the OFF position.
Verify that all of the sensors are disconnected.
Measure the resistance between terminal A (+5V) and terminal B (Common) of each pressure sensor connector.Expected Result:The resistance is greater than 20,000 Ohms, or "OL" is displayed on the multimeter.Results:
OK - The 5 volt supply and the pressure sensor common are not shorted.Repair: Check the 5 volt supply for a short to ground.Repair the 5 volt supply wire or replace the 5 volt supply wire.Verify that the repair eliminates the problem.STOP
Not OK - There is a short between the 5 volt supply and the pressure sensor common.Repair: Locate the short between the 5 volt supply and the pressure sensor common.Repair the faulty wiring or replace the faulty wiring.Verify that the repair eliminates the problem.STOP


Parts screw Mariner:

62568
 
62568 SCREW, FUEL GAUGE
7001200, 7004201, 7005201, 7005207, 7005227, 7006201CD, 7006201HB, 7008204, 7008208, 7008218EW, 7008226, 7008237, 7008238, 7008247, 7008248, 7008305, 7010207HB, 7010209, 7010312DT, 7015201LD, 7015207, 70152374D, 7015307, 7015327, 7015529, 7020201, 70
48408
 
48408 SCREW, TELL TALE NOZZLE TO BOTTOM COWL (1/2")
7006201CD, 7006201HB, 7006201TB, 7008218EW, 7008237, 7010207HB, 7010312DT, 7011201TB, 7015201LD, 70152374D, 7016207CD, 7020201HB, 7020201NC, 7020201TB, 7031203GD, 7031207CD, 7045217, 7050200, 7050412YD, 7050716, 7050717, 7060312PC, 7060412ET, 7060524
69100
 
69100 SCREW, CYLINDER BLOCK COVER MOUNTING (1")
7045217, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070520, 7075524, 7080508, 7080629, 7085507, 7090520, 7090524, 7115520, 7115528, 7115529, 7140528, 7140629
66024
 
66024 SCREW, TRIM TAB TO GEAR HOUSING (1 3/4")
70404119D, 7045217, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520, 7075524, 7080508, 7080629, 7085507, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 71354120D, 7135417PD, 7135826, 7140528, 7140629, 7150453ND, 7150453PD, 7150
47828
 
47828 SCREW, DRIVE - SWIVEL BRACKET
7080508, 7085507, 7090529, 7115528, 7115529, 7140528, 7140629
30902
 
30902 SCREW, SAFETY SWITCH TO CONTROL HOUSING
7070509, 7080508, 7090529, 7115528, 7115529, 7140528, 7140629
23015
 
23015 SCREW, UPPER CARBURETOR FILTER SCREEN TO CARB. (1")
70404119D, 7045217, 7050200, 7050716, 7060312PC, 7060524, 7070520, 7090520, 7090529, 7115520, 7115528, 7115529, 7140528, 7140629
33524
 
33524 SCREW, CHOKE SOLENOID ATTACHING (5/8")
7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520
Back to top