821300 12 Mariner SCREW, (M6 x 12)


821300 12 SCREW, (M6 x 12) Mariner 7075D73UY, 7075D73ZY, 7090D73RD, 7115473JD, 7135473GD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7200413JD, 7200413UY, 7200413ZY, 7200423UY, 7200473FD, 7200473GD, 7200473HD, 7200473JD, 7200473K SCREW
821300 12 SCREW, (M6 x 12) Mariner
Rating:
98

Buy SCREW, (M6 x 12) 821300 12 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 12
 

Mariner entire parts catalog list:

7075D73UY 2006
7075D73ZY 2006
7090D73RD 2004,2005
7115473JD 2000
7135473GD 1998
7135473HD 1999
7135473KD 2001,2002,2003
7135D73RD 2004,2005
7135D73UY 2006
7135D73ZY 2006
7150413LD 2002,2003
7150413RD 2004,2005
7150413UY 2006
7150413ZY 2006
7200413JD 2000
7200413UY 2006
7200413ZY 2006
7200423UY 2006
7200473FD 1997
7200473GD 1998
7200473HD 1999
7200473JD 2000
7200473KD 2001,2002
7200D73IY 2006
7200D73MD 2003
7200D73RD 2004,2005,2006
7200D73ZY 2006
7225412CD 1994,1995,1996,1997,1998
7225412HD 1999,2000,2001
7225413DD 1995,1996,1997,1998
7225413HD 1999,2000,2001
7225413IY 2006

Information:

idle shutdown is suspected of incorrect operation.The following background information is related to this procedure:"Idle Shutdown Timer"The "Idle Shutdown Timer" is intended to improve fuel economy by limiting idling time.The "Idle Shutdown Timer" is a "Customer Specified Parameter" that may be programmed for any period from 3 to 1440 minutes.The timer is activated when all of the following conditions are met regardless of the position of the parking brake:
The vehicle speed is 0.
The engine is not in "Cold Mode" or "Dedicated PTO Mode".
The engine is not under load.The timer can be reset by moving the vehicle or the timer can be reset by quickly depressing the accelerator pedal and releasing the accelerator pedal.The check engine lamp will begin to rapidly flash 90 seconds before the programmed time expires. During this 90 second time period, the following conditions can disable the timer:
The driver moves the clutch pedal.
The driver moves the service brake pedal.The following event code will be logged when the driver overrides the timer by the use of the clutch pedal or the brake pedal during the 90 second period:
71-00 Idle Shutdown Override (01)If the parameter for the "Allow Idle Shutdown Override" is programmed to "NO", the timer cannot be overridden by the use of the clutch pedal or the brake pedal during the final 90 second period. "YES" is the factory default that is programmed for the parameter for the "Allow Idle Shutdown Override". The allowance of the override is the default.
71-01 Idle Shutdown Occurrence (47)Code 71-01 records the event and the code does not indicate an electrical system malfunction or an electronic system malfunction. Disable the timer by programming "Idle Shutdown Timer" to 0 (factory default).The ECM will shut down the engine but not the vehicle electrical system when the "Idle Shutdown Timer" time expires. The "Engine Shutdown Output" can be used to shut down the vehicle electrical system after the "Idle Shutdown Timer" time has expired. If auxiliary output 1, auxiliary output 2, or auxiliary output 3 is programmed to "Engine Shutdown Output", the ECM and portions of the truck electrical system will be shutdown.The "Idle Shutdown Timer" feature can be temporarily disabled by the use of the Caterpillar Electronic Technician (ET). The "Idle Shutdown Timer" feature can be temporarily disabled through the "System Troubleshooting Settings" screen in order to help troubleshoot other problems. Temporarily disabling this feature avoids engine shutdowns when you are troubleshooting other systems. The use of this method eliminates the need to temporarily alter the customer specified parameter of "Idle Shutdown Timer".Note: If the following diagnostic code is active, the "Idle Shutdown Timer" will not operate.
84-08 Vehicle Speed Out Of Range (36)Note: The timer will be overridden if the following conditions exist.
The "Allow Idle Shutdown Timer Override" is programmed to "Outside Temperature Based" or "J1587 Outside Temperature Based".
The temperature that is being sensed by the ECM is below the minimum air temperature that is programmed or the air temperature is above the maximum air temperature that is programmed.Test Step 1. Verify Activation of the "Idle Shutdown Timer"
Connect Cat ET to the cab data link connector.
Access the "Customer Parameters" on Cat ET.
Access the following display screens in order:
"Service"
"Configuration"
Record the programmed time for the "Idle Shutdown Timer". The "Idle Shutdown Timer" must be between 3 and 1440 minutes. If the "Idle Shutdown Timer" is programmed to 0, then the timer is disabled.
Record the programmed status of the parameter for the "Allow Idle Shutdown Override" and the "Idle Shutdown Timer Maximum RPM".
Start the engine. Allow the engine to warm up until the coolant temperature is 38 °C (100 °F). Allow the engine to operate at the programmed low idle and turn off any unnecessary accessory devices.
Ensure that all unnecessary loads are turned off.
Park the vehicle.
Ensure that the "Vehicle Speed" on the status screen on Cat ET is 0 km/h (0 mph).
Ensure that the engine speed on the status screen is at "Low Idle".
Ensure that auxiliary input 1 on the status screen is OFF.
Ensure that the clutch pedal is not depressed. Ensure that the brake pedal is not depressed.
Ensure that the status of the PTO On/Off switch is off.
Observe the "Idle Shutdown Status".Expected Result:Result 1 The "Idle Shutdown Status" indicates "Counting".Result 2 The "Idle Shutdown Status" indicates "Not Active".Results:
Result 1 - The ECM is reading the proper conditions for the activation of the "Idle Shutdown Timer". Proceed to Test Step 2.
Result 2 - The ECM is not reading the proper conditions for activation of the "Idle Shutdown Timer". Proceed to Test Step 3.Test Step 2. Verify the Driver Alert Function for Idle Shutdown and the Override Function for Idle Shutdown
Connect Cat ET to the cab data link connector.
Access the "Customer Parameters" on Cat ET.
Access the following display screens in order:
"Service"
"Configuration"
Record the programmed time for the "Idle Shutdown Timer". The "Idle Shutdown Timer" must be between 3 and 1440 minutes. If the "Idle Shutdown Timer" is programmed to 0, the timer is disabled.
Reprogram the "Idle Shutdown Timer" to 3 minutes for this test.
Observe the following items during the 90 second period before the programmed shutdown time:
Check engine lamp
Idle shutdown status
If the customer parameter of "Allow Idle Shutdown Override" is programmed to "YES", perform either of the following actions in order to override the shutdown:
Press the clutch pedal.
Press the service brake pedal.Note: This action must be accomplished while the check engine lamp is flashing. The check engine lamp flashes during the 90 second period before the programmed shutdown time.
Reprogram the "Idle Shutdown Timer" to the value that was recorded earlier for this test.Expected Result:During the 90 second period before the scheduled shutdown, the status should change from "Counting" to "Driver Alert" and the check engine lamp should flash rapidly. If the "Allow Idle Shutdown Override" is programmed to "YES", the "Idle Shutdown Status" should change to "Override" after the pedals are depressed.Result 1 The "Idle Shutdown Timer" behaves in the manner that is described above.Result 2 The check engine lamp did not flash during the alert.Result 3 The ECM did not sense a change in the status


Parts screw Mariner:

811248M
SCREW
811248M SCREW
7008218EW, 7008425, 7025208CW, 7F10203HD, 7F13203UB, 7F15201GD
40011107
SCREW, HOUSING TO ADAPTOR PLATE (16MM)
40011107 SCREW, HOUSING TO ADAPTOR PLATE (16MM)
7006201CD, 7006201HB, 7006201TB, 7008218EW, 7008237, 7010207HB, 7010312DT, 7011201TB, 7015201LD, 70152374D, 7016207CD, 7020201HB, 7020201NC, 7020201TB, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD,
94320
 
94320 SCREW
7075217CD, 7075217HD, 7075217TD, 7075217UD, 70752L7TF, 70752L7UF, 7075312ND, 7075312SD, 7075317TB, 7075317UB, 7075412TB, 7075412UB, 7075412UY, 7075717, 7075D73UY, 7075D73ZY, 7090412TB, 7090412TD, 7090412TY, 7090412UB, 7090412UY, 7090D73RD, 7100412CD,
814945
SCREW, (.312-18 x 3.500), CLAMP BRACKET TO TRANSOM
814945 SCREW, (.312-18 x 3.500), CLAMP BRACKET TO TRANSOM
70152374D, 7020201HB, 7020201NC, 7020201TB, 7F08201TB, 7F10203HD, 7F13203UB, 7F15201GD
824706 20
 
824706 20 SCREW, (M3.5 x 20)
7200413JD, 7200473FD, 7200473GD, 7200473HD, 7200473JD, 7200473KD, 7200D73IY, 7200D73MD, 7200D73RD, 7200D73ZY, 7225412CD, 7225412HD, 7225413DD, 7225413HD, 7225413IY, 7225413LD, 7225413RD, 7225413ZY, 7225E73MD, 7250423IY, 7F10203HD, 7F13203UB, 7F15201G
14000 1
 
14000 1 SCREW, (.375-24 x 1.38)
7115473JD, 7135412ED, 7135412HD, 7135412JD, 7135473GD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413ED, 7150413HD, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7150423JD, 7175423HD, 7200413JD, 7200413UY, 7200413ZY, 7200423UY, 7200473G
804526
SCREW PACKAGE, (M5 x 16) (2 Per)
804526 SCREW PACKAGE, (M5 x 16) (2 Per)
7115473JD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7200473HD, 7200473JD, 7200473KD, 7200D73IY, 7200D73MD, 7200D73RD, 7200D73ZY, 7225E73MD
79953Q04
SCREW KIT, Drain
79953Q04 SCREW KIT, Drain
7135D73ZY, 7A30453VZ, 7A40302ZZ, 7A40312ZZ, 7A40412ZZ, 7A41452IZ, 7A51412ZZ, 7A51452IZ, 7A60412ZZ, 7A60452IZ, 7E41412ZB, 7E51412ZB, 7E51413VZ, 7E60412ZB, 7E60413VZ, 7E60452IZ, 7E60452ZB, 7F40203ZZ
Back to top