83375M Mariner SCREW, PLUG


83375M SCREW, PLUG Mariner 7040207, 7040208, 7040328, 7040507 SCREW
83375M SCREW, PLUG Mariner
Rating:
88

Buy SCREW, PLUG 83375M Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

Compatible models:

Mariner entire parts catalog list:

7040207 1977
7040208 1978
7040328 1978,1980
7040507 1987

Information:


During operation, the oxygen sensor may reach temperatures that exceed 700 °C (1292 °F). Severe personal injury and property damage will result from contact with a hot oxygen sensor.Do not touch the sensor during engine operation, calibration, or testing. Allow the sensor to cool before moving the sensor. Wear gloves that resist heat. Do not place the sensor on or near any flammable material or any surface that can be damaged by high temperatures.
Set the engine control to the OFF/RESET mode. Remove the electrical power from the engine.
Thoroughly inspect the following connectors:
Connectors for the ECM
Connectors for the oxygen sensor and the oxygen buffer
Check the harness and wiring for abrasion and pinch points from the oxygen sensor to the ECM.Expected Result:All of the connectors, pins, and sockets are connected properly. The connectors and the wiring are free of corrosion, abrasion, and pinch points.Results:
OK - The components are in good condition with proper connections. Proceed to Test Step 2.
Not OK - At least one of the connectors, pins, or sockets are not connected properly. At least one of the connectors or the wiring has corrosion, abrasion, and/or pinch points.Repair: Perform the necessary repairs and/or replace parts, if necessary.STOPTest Step 2. Check the Atmospheric Conditions
Determine the ambient temperature, relative humidity, and barometric pressure.
Use Table 1 to determine whether your relative humidity is within the permissible range for calibration of the oxygen sensor.
Find the row for your ambient temperature.If the temperature is less than 12 °C (54 °F), use the 12 °C (54 °F) row.If the temperature is more than 38 °C (100 °F), do not calibrate the sensor.
Find the column for your barometric pressure.
Find the relative humidity in the cell that intersects your column and your row.If your relative humidity is equal to the humidity or greater than the humidity that is listed in the Table, do not calibrate the sensor.If the humidity is 90 percent or more, do not calibrate the sensor.
Table 1
Ambient Temperature, Barometric Pressure, and Relative Humidity for Calibration of the Oxygen Sensor    
Ambient Temperature     Barometric Pressure    
96 kPa (13.9 psi)
97 kPa (14.7 psi)    
99 kPa (14.4 psi)    
101 kPa (14.6 psi)    
102 kPa (14.8 psi)    
104 kPa (15 psi)    
105 kPa (15.2 psi)    
107 kPa (15.5 psi)    
109 kPa (15.8 psi)    
110 kPa (16 psi)    
112 kPa (16.2 psi)    
113 kPa (16.4 psi)    
Relative Humidity
12 °C (54 °F)     90     90     90     90     90     90     90     90     90     90     90     90    
14 °C (57 °F)     85     85     85     85     90     90     90     90     90     90     90     90    
16 °C (61 °F)     75     75     75     75     80     80     80     80     85     85     85     85    
18 °C (64 °F)     65     65     65     70     70     70     70     75     75     75     75     75    
20 °C (68 °F)     60     60     60     60     60     65     65     65     65     65     65     70    
22 °C (72 °F)     50     50     55     55     55     55     55     60     60     60     60     60    
24 °C (75 °F)     45     45     45     50     50     50     50     50     50     55     55     55    
26 °C (79 °F)     40     40     40     45     45     45     45     45     45     45     50     50    
28 °C (82 °F)     35     35     40     40     40     40     40     40     40     40     45     45    
30 °C (86 °F)     35     35     35     35     35     35     35     35     35     40     40     40    
32 °C (90 °F)     30     30     30     30     30     30     35     35     35     35     35     35    
34 °C (93 °F)     25     25     30     30     30     30     30     30     30     30     30     30    
36 °C (97 °F)     25     25     25     25     25     25     25     25     25     30     30     30    
38 °C (100 °F)     20     25     25     25     25     25     25     25     25     25     25     25    Expected Result:The temperature is less than 38 °C (100 °F). The ambient relative humidity is within the permissible range for calibration of the oxygen sensor.Results:
OK - The ambient conditions are acceptable. Proceed to Test Step 3.
Not OK - The humidity is not acceptable.Repair: Do not calibrate the sensor until the humidity is acceptable.STOPTest Step 3. Check for Diagnostic Codes
Restore the electrical power to the engine. Set the engine control to the STOP mode.
Use an electronic service tool in order to check for the following codes. If the following codes are activated, clear the codes:
550-02 Noisy or Loss of Oxygen Signal
551-01 Oxygen Sensor not connected to buffer


Parts screw Mariner:

83509M
 
83509M SCREW
7002200, 7002207, 7004201, 7008204, 7008218EW, 7008226, 7008425, 7010209, 7015327, 7015529, 7025207PW, 7040207, 7040507, 7055524, 7060507, 7F08203HF, 7F08261DF, 7F75411JD, 7F75412RD
83108M
 
83108M SCREW (LONG)
7004201, 7005201, 7005207, 7008218EW, 7008425, 7015207, 7040202, 7040206, 7040207, 7040208, 7040208PW, 7040328, 7040507, 7040716
82492M
 
82492M SCREW, COVER ATTACHING
7008208, 7008238, 7008248, 7008305, 7015207, 7015307, 7015327, 7020201, 7025200, 7025207NW, 7025500, 7028207, 7028527, 7030200, 7040202, 7040207, 7040208, 7040328, 7040507, 7040716, 7060522
82487M
 
82487M SCREW
7010209, 7015529, 7020201, 7025200, 7025500, 7026226, 7028527, 7030200, 7030205, 7040202, 7040207, 7040208, 7040507, 7040716, 7055524, 7060507, 7060522, 7060528
80164M
 
80164M SCREW
7020201, 7025200, 7025500, 7026226, 7028527, 7030200, 7030205, 7040202, 7040207, 7040208, 7040507, 7040716, 7060507, 7060528
83371M
 
83371M SCREW WITH WASHER
7040202, 7040206, 7040207, 7040208, 7040328, 7040507, 7040716, 7048207, 7048227, 7048321, 7060507, 7060528
83373M
 
83373M SCREW WITH WASHER
7008204, 7008208, 7008226, 7040202, 7040206, 7040207, 7040208, 7040328, 7040507, 7040716
83374M
 
83374M SCREW
7040207, 7040208, 7040507
Back to top