812611 Mariner SPACER-COVER SCREW


812611 SPACER-COVER SCREW Mariner 70404119D SPACER
812611 SPACER-COVER SCREW Mariner
Rating:
88

Buy SPACER-COVER SCREW 812611 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$204.20
 

26-09-2017

SKOOKUM: SKOOKUM
SKOOKUM #126 1 3/8" Guyline Sleeve Only (812611)
 

26-09-2017

Hillman: Hillman
812611 1/2-in-13 x 2-1/2-in Hot-Dipped Galvanized Carriage Bolt
$27.14
 

26-01-2022
8.7[3.60] Pounds
-: -
Hillman 812611 Hot Dipped Galvanized Carriage Bolt, 1/2 x 2-1/2-Inch, Silver, 50-Pack
Carriage Bolts are designed to fasten a wooden face to either wood or metal || Flat head provides a semi-flush finish to applications || The heads is designed to eliminate the need for a washer || Square underside of the head is self locking to eliminate the need for a driving tool || Galvanized finish is perfect for rust prevention
Number on catalog scheme: 44
 

Compatible models:

70404119D   Mariner

Mariner entire parts catalog list:

70404119D 1989,1990,1991,1992,1993,1994,1995,1996,1997

Information:

Drain the Cooling System
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Ensure that the engine will not start when the cooling system is drained.
Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap.Note: For the location of the coolant drain, see the service literature that is provided by the OEM of the locomotive.
Illustration 1 g00831734
Location of the cooling system drain plugs (1) Oil cooler (2) Jacket water pump (3) Cylinder blockNote: If the engine has a jacket water heater, drain the coolant from the heater.
Open the coolant drain. Remove cooling system drain plug (1). Remove cooling system drain plug (2). Remove cooling system drain plug (3). Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tools:Outside U.S.A.: (309) 675-6277Inside U.S.A.: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOLCOSA Geneva, Switzerland: 41-22-849 40 56Clean the Cooling System
Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the cooling system drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 30 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Open the coolant drain. Remove the cooling system drain plugs. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs. Open the water inlet for the separate circuit aftercooler (if equipped).Cleaning a Cooling System that has Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be an active flow through the cooling system components.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine for a minimum of 90 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Close the water inlet for the separate circuit aftercooler (if equipped). Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. Remove the cooling system drain plugs. Open the coolant drain. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the coolant drain. Clean the cooling system drain plugs and install the cooling system drain plugs.Fill the Cooling System
Note: For information about the proper coolant to use, see Special Publication, SEBU6251, "Caterpillar Commercial Diesel Engine Fluids Recommendations". For the capacity of the cooling system, see this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with antifreeze/coolant. After filling the cooling system, do not install the radiator filler cap.
Open the water inlet for the separate circuit aftercooler (if equipped). Start the engine. Operate the engine in order to purge the air from the cavities of the engine block. Allow the coolant to warm and allow the coolant level to stabilize. Stop the engine.
Check the coolant level. Maintain the coolant to the proper level on the sight gauge (if equip


Parts spacer Mariner:

56774
 
56774 SPACER, COLLAR TO BRACKET
70404119D, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520, 7075524, 7080508, 7080629, 7085507, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 7140528, 7140629, 7150629, 7175629, 7200620
63061
 
63061 SPACER, SHEAVE SHAFT
70404119D, 7045217, 7050200, 7050716
48525
 
48525 SPACER, HANDLE BRACKET
70404119D, 7045217, 7050200, 7050716
41130
17406
 
17406 SPACER
70404119D
816086
SPACER
816086 SPACER
7031203GD, 7031207CD, 7031207LF, 7031312TB, 70404119D, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050302ED, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7050412YD, 7055207GD, 7055207HB, 7055207TF, 7060412E
Back to top