Table 1
Diagnostic Codes    
Code and Description    Conditions which Generate this Code    System Response    
100-13
Engine Oil Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to 0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
101-13
Engine Crankcase Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
108-13
Barometric Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
289-13
Fuel Pressure Sensor - Before Fuel Filter : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
1208-13
Engine Pre-filter Oil Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
1785-13
Intake Manifold Pressure Sensor : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
3528-13
Barometric Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
3563-13
Engine Intake Manifold #1 Absolute Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
5422-13
Engine Intake Manifold #2 Absolute Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    
5578-13
Engine Fuel Delivery Absolute Pressure : Out of Calibration     During the last calibration attempt, a problem has been detected.     The code is logged.
During a manual calibration, the pressure offset value is set to
0 kPa (0 psi).
During an automatic calibration, the pressure offset value is set to the previous calibration value.    The Electronic Control Module (ECM) attempts to perform an automatic calibration of all pressure sensors whenever the ECM is powered. The engine must have been off for at least 10 seconds. Cranking the engine during the first 10 seconds causes the ECM to abort the calibration attempt.During an automatic pressure sensor calibration, the ECM checks all pressure sensors against an acceptable range. If any pressure sensor reading is outside the acceptable range, the previous calibration value is used. The ECM then calibrates all pressure sensors against the atmospheric pressure sensor.A pressure sensor calibration will not be successful if there are active sensor diagnostic codes with an FMI of 03 and/or 04. Check for active diagnostic codes and/or for logged diagnostic codes. Troubleshoot any diagnostic codes that are present before continuing with this procedure.A pressure sensor calibration will not be successful if one of the following conditions exist:
The pressure reading is outside of an acceptable range.
The pressure reading varies significantly during calibration.
Table 2
Calibration Tolerances for Pressure Sensors    
Code     Sensor Reference     Minimum Allowable Reference Value     Maximum Allowable Reference Value     Maximum Allowable Range For Calibration     Minimum Allowable Calibration Value     Maximum Allowable Calibration Value    
101-13     Atmospheric pressure sensor    
0 kPa (0 psi)    
0 kPa (0 psi)    
15 kPa (2.2 psi)    
-20 kPa (-2.9 psi)    
20 kPa (2.9 psi)    
1785-13     Atmospheric pressure sensor    
35 kPa (5.1 psi)    
122 kPa (17.7 psi)    
15 kPa (2.2 psi)    
35 kPa (5.1 psi)    
122 kPa (17.7 psi)    
3563-13    
5422-13     Atmospheric pressure sensor    
35 kPa (5.1 psi)    
122 kPa (17.7 psi)    
15 kPa (2.2 psi)    
35 kPa (5.1 psi)    
122 kPa (17.7 psi)    Note: The engine coolant temperature must be greater than 0° C (32° F) before this procedure is performed.Check for active calibration codes. Use Caterpillar Electronic Technician (ET) to check for calibration codes that are active or logged.Perform the following procedure in order to troubleshoot active calibration codes:
Inspect the connector of the suspect sensor. Verify that no moisture or corrosion is present in the connector assembly. Thoroughly inspect the connector seal for damage. Reconnect the connector.
Monitor the status parameter for the suspect sensor on Cat ET. Wiggle the wiring at the suspect sensor connector. While you wiggle the wiring, check that the value of the status parameter remains steady during the test.If the value of the status parameter does not remain steady during the test, perform the necessary repairs to the wiring and/or the sensor connector.Verify that the problem is resolved.If the value of the status parameter remains steady during the test, use Cat ET to check for an active calibration code. If the code is


Parts spring Mariner:

82596M
 
82596M SPRING
7002207, 7F08203HF, 7F08261DF
80437M
 
80437M SPRING, AIR ADJUSTING SCREW...
7008238, 7008247, 7040207PW, 7040208PW, 7F08203HF, 7F08261DF
96203
 
96203 SPRING, PILOT CONTROL SCREW - EARLY STYLE
7006201CD, 7006201HB, 7006201TB, 7008218EW, 7010207HB, 7010312DT, 7011201TB, 7015201LD, 70152374D, 7016207CD, 7020201HB, 7020201TB, 7020207, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB,
824994
SPRING, Plate
824994 SPRING, Plate
70152374D, 7016207CD, 7020201HB, 7020201TB, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7A30302LB, 7A40302UD, 7A40312U
824993
 
824993 SPRING-BACKING
7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7A30302LB, 7A40302UD, 7A40312UZ, 7F08203HF, 7F08261DF, 7F10203HD, 7F13203U
827479M
 
827479M SPRING
7F08203HF, 7F08261DF
852778 3
 
852778 3 SPRING, Return
7F10203HD, 7F13203UB, 7F15201GD
856036 1
 
856036 1 SPRING, Return
7F10203HD, 7F13203UB, 7F15201GD
Back to top