8778A23 Mariner STATOR


8778A23 STATOR Mariner 7100412NC STATOR
8778A23 STATOR Mariner
Rating:
28

Buy STATOR 8778A23 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$168.00

07-01-2025

CN: TongBTKJ
Stator for Mercury Force 174-8778K 1 Outboard 30 Jet 40 50 70 75 80 90 100 115 120 HP 398-8778A16 8778A17 818535A3 9-Amp 2 Stroke 2,3&4 Cylinder
GOTBITOU ✅【Replace】For Mercury Mariner Stator || ✅【Note】Check manufacturer's recommended part numbers to ensure a proper fit For your application || ✅【Warranty】1-year warranty protects you after your purchase || ✅【Service】If you have a problem,We will take every step to assist you,Contact us and we will respond within 24 hours || ✅【OEM】174-8778K1 18-5873 18-5874 398-818535A3 818535A5 818535A8 818535A9 818535A10 818535A11 818535A13 818535A14 818535A15 8778A6 8778A10 8778A16 8778A17 8778A18 8778A21 8778A22 8778A23 8778A24 8778A25 8778A26 8778A27 8778A28 8778A29
$178.00

07-01-2025

US: fengzhou keji
OMGparts Stator for Mariner/Mercury/Force/Sportjet 9 Amp Outboard 40hp-125hp 2/3/4 Cylinder 2-Stroke (1987-1995) Boat Parts 398-8778A10 174-8778K1
jetunit ✅【Replace】For Mercury Mariner Stator || ✅【Note】Check manufacturer's recommended part numbers to ensure a proper fit For your application || ✅【Warranty】1-year warranty protects you after your purchase || ✅【Service】If you have a problem,We will take every step to assist you,Contact us and we will respond within 24 hours || ✅【OEM】174-8778K1 18-5873 18-5874 398-818535A3 818535A5 818535A8 818535A9 818535A10 818535A11 818535A13 818535A14 818535A15 8778A6 8778A10 8778A16 8778A17 8778A18 8778A21 8778A22 8778A23 8778A24 8778A25 8778A26 8778A27 8778A28 8778A29
$193.99

07-01-2025
3.06[1.38] pounds
US: Total Power Parts
Total Power Parts 340-22062 Stator Replacement For: Force Various, Mercury Marine Various 398-818535A10, 398-818535A13, 398-818535A14, 398-818535A3, 398-818535A5, 398-818535A8, 398-818535A9
Total Power Parts Specs: Stator Coil, Voltage: 12, Dimension: 12 Post, 97.9mm ID, 170.9mm OD, 28.4mm Width, (12) 5.4mm ID Unthreaded Mounting Holes, (6) Wire Harness, 580mm Length, (2) Yellow Wires, (1 each) Red, Blue, Red/White, Blue/White Wires, 3.6mm Female Bullet Connectors, Compatible with/Replacement for: Used on Mercury 70, 75, 90HP – 3cyl Engines 1987-96, Mercury 40, 100, 115, 125HP – 4cyl 1988-96, Force 40, 50HP – 2cyl 1992-95, Force 70, 90HP – 3cyl 1991-95, Force 120HP – 4cyl 1991-95 || Replaces OEM Numbers: ARROWHEAD: 340-22062, J & N: 340-22062, MERCURY MARINE: 398-818535A10, 398-818535A13, 398-818535A14, 398-818535A3, 398-818535A5, 398-818535A8, 398-818535A9, 398-8778A21, 398-8778A22, 398-8778A23, 398-8778A24, 398-8778A25, 398-8778A26, 398-8778A27, 398-8778A28, 398-8778A29, 818535A14, 8778A23, 8778A26, 8778A29, SIERRA MARINE: 18-5873, TEMCO: TM-ST163 || Compatible With/Replacement For: MERCURY MARINE 100.0HP / 4cyl - SN 0A722297 Thru 0D283221 All, 115.0HP / 4cyl - SN 0C100000 Thru 0D283221 All, 120 Jet Drive - SN 0E080400 Thru 0E145579 1995-1995, 120 Powerhead - SN 0E095088 Thru 0E141088 1995-1995, 90 Jet Drive - SN 0E021000 Thru 0E036999 1993-1993, 90 Powerhead (Non-Oil Injected) - SN 0E023150 Thru 0E033710 1993-1993, 90 Powerhead (Non-Oil Injected) - SN 0E033711 Thru 0E066619 1994-1994 || 1-year warranty protects you after your purchase. We're confident that our products will work flawlessly once installed in your vehicle. But in a rare case that it does not, we'll replace it anytime within one year of your order. If you have a problem, we will take every step to assist you, contact us for a replacement. || 100% New Aftermarket Stator Coil built to meet OEM specifications
Number on catalog scheme: 9
 

Compatible models:

7100412NC   Mariner

Mariner entire parts catalog list:

7100412NC 1988,1989,1990,1991,1992,1993

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
639-9
J1939 Network #1 : Abnormal Update Rate 247-9
J1939 Network #1 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
639-14
J1939 Network #1 : Special Instruction 247-14
J1939 Network #1 : Special Instruction The affected ECM is missing expected parameters.
1231-9
J1939 Network #2 : Abnormal Update Rate 2348-9
J1939 Network #2 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1231-14
J1939 Network #2 : Special Instruction 2348-14
J1939 Network #2 : Special Instruction The affected ECM is missing expected parameters.
1235-9
J1939 Network #3 : Abnormal Update Rate 5856-9
J1939 Network #3 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1235-14
J1939 Network #3 : Special Instruction 5856-14
J1939 Network #3 : Special Instruction The affected ECM is missing expected parameters.
2853-9
Communications Connection : Abnormal Update Rate N/A Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
3360-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate 3820-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate The DCU triggered a CAN communication diagnostic code and shut the SCR system down. Troubleshoot and repair the same as a 1235-9 code, perform an Aftertreatment System Functional Test to verify the repair
Table 2
Associated Diagnostic Trouble Codes
J1939 Code CDL Code
5965-5 3838-5
5965-6 3838-6
5966-6 3965-6 If the Cat® Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the ECM and to the service tool connector.The Systems Communication Status is located under the diagnostics tab in Cat ET. Click the "System Communication Status" option. Once the screen opens up, the information will automatically be loaded from the ECM. If there is an issue with the data link and the data link is repaired, the "Load from ECM" button will have to be clicked again to see the updated status. If there are communication issues between multiple modules, each module can be selected individually to determine which components are having communication issues. If the problem is intermittent, the "View History" button can be clicked to see all the communication faults that have previously logged.
Table 3
Cat® ET Diagnostic Code Cross Reference to Wiring Schematic
Code Description Data Link
J1939 Network #1 Can A
J1939 Network #2 Can B
J1939 Network #3 Can C
Illustration 1 g06156053Note: The DEF Quality Sensor is only available on 2017model or later.-9 Detected Problems:Device 1 is unable to communicate on the data link.
Device 1 cannot communicate with other devices on the data link, but can communicate with the service tool, indicating a problem with the data link wiring.Device 1 is unable to communicate with Device 2 on the data link.
Device 1 cannot communicate with Device 2, indicating a problem with the data link wiring, power or ground circuit, or Device 2.Note: If a 639-9 or 247-9 code is active and the "System Communication Status" indicates a communication problem with the "Aftertreatment #1 DEF Sensor", confirm that the "Aftertreatment #1 DEF Quality Sensor Installation Status" configuration parameter is programmed properly.The "Aftertreatment #1 DEF Quality Sensor Installation Status" parameter must be programmed to "Not Installed", if equipped with a DEF header having a 3-pin connector without an internal DEF quality sensor.-14 Detected Problems:Device 1 is unable to obtain a network address on the data link.
Device 1 is trying to claim the same address as another Device. An example of this is 2 devices being configured the same.Device 1 detects a failed address claim from Device 2 on the data link.
Device 1 detects that Device 2 is trying to claim the same address as another device.Device 1 is not receiving all expected parameters from Device 2 on the data link.
A component is configured as installed in the device, but is not installed on the application.
The incorrect component is installed.
The incorrect software file has been installed.
Table 4
Troubleshooting Test Steps Values Results
1. Check for Associated Diagnostic Trouble Codes
A. Establish communication between Cat ET and the ECM. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
Troubleshoot any associated diagnostic codes that are present before continuing with this procedure.
Associated Codes
Result: An associated diagnostic trouble code is not active or logged.
Proceed to Test Step 2.
Result: An associated code is active or logged.
Repair: Troubleshoot the associated codes before continuing with this procedure.
Refer to Troubleshooting, "Diagnostic Trouble Codes" to troubleshoot the associated diagnostic code.
2. Use the "System Communication Status" to Determine the Communication Issue
A. In Cat ET, click the "Diagnostics" tab on the tool bar.
B. Select the "System Communication Status" option from the drop-down list.
Note: The Aftertreatment #1 Intake NOx Level Sensor is displayed as Aftertreatment #1 Information #1 in some versions of software.
Component Identified
Result: A -9 code is active.
Repair: Refer to the above -9 detected problems for more information.


Back to top