Table 1
Cross-Reference from "SPN-FMI Code" to Functional Test or Procedure
"SPN-FMI Code" Functional Test or Procedure
171-3
Ambient Air Temperature : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
171-4
Ambient Air Temperature : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
444-2
Battery Potential / Power Input #2 : Erratic, Intermittent, or Incorrect Troubleshooting, "Electrical Power Supply - Test"
444-3
Battery Potential / Power Input 2 : Voltage Above Normal Troubleshooting, "Electrical Power Supply - Test"
444-4
Battery Potential / Power Input 2 : Voltage Below Normal Troubleshooting, "Electrical Power Supply - Test"
631-2
Calibration Module : Erratic, Intermittent, or Incorrect Troubleshooting, "ECM Software - Install"
1761-3
Aftertreatment #1 DEF Tank Volume : Voltage Above Normal Troubleshooting, "DEF Tank Sensor - Test"
1761-4
Aftertreatment #1 DEF Tank Volume : Voltage Below Normal Troubleshooting, "DEF Tank Sensor - Test"
3031-3
Aftertreatment #1 DEF Tank Temperature : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
3031-4
Aftertreatment #1 DEF Tank Temperature : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
3216-6
Aftertreatment #1 Intake NOx : Current Above Normal Troubleshooting, "NOx Sensor Supply - Test"
3216-9
Aftertreatment #1 Intake NOx : Abnormal Update Rate Troubleshooting, "Data Link - Test"
3216-12
Aftertreatment #1 Intake NOx : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
3226-6
Aftertreatment #1 Outlet NOx : Current Above Normal Troubleshooting, "NOx Sensor Supply - Test"
3226-9
Aftertreatment #1 Outlet NOx : Abnormal Update Rate Troubleshooting, "Sensor (Data Link Type) - Test"
3226-12
Aftertreatment #1 Outlet NOx : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
3265-6
Aftertreatment #2 Outlet NOx : Current Above Normal Troubleshooting, "NOx Sensor Supply - Test"
3265-9
Aftertreatment #2 Outlet NOx : Abnormal Update Rate Troubleshooting, "Sensor (Data Link Type) - Test"
3265-12
Aftertreatment #2 Outlet NOx : Failure During a self-test, the NOx sensor has detected an internal fault.
Replace the sensor.
3363-5
Aftertreatment #1 DEF Tank Heater : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
3363-6
Aftertreatment #1 DEF Tank Heater : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
3509-3
Sensor Supply Voltage 1 : Voltage Above Normal Troubleshooting, "Sensor Supply - Test"
3509-4
Sensor Supply Voltage 1 : Voltage Below Normal Troubleshooting, "Sensor Supply - Test"
3510-3
Sensor Supply Voltage 2 : Voltage Above Normal Troubleshooting, "Sensor Supply - Test"
3510-4
Sensor Supply Voltage 2 : Voltage Below Normal Troubleshooting, "Sensor Supply - Test"
4334-3
Aftertreatment #1 DEF #1 Pressure (absolute) : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4334-4
Aftertreatment #1 DEF #1 Pressure (absolute) : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4335-3
Aftertreatment #1 SCR Dosing Air Assist Absolute Pressure : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4335-4
Aftertreatment #1 SCR Dosing Air Assist Absolute Pressure : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4336-5
Aftertreatment #1 SCR Dosing Air Assist Valve : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
4336-6
Aftertreatment #1 SCR Dosing Air Assist Valve : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
4337-3
Aftertreatment #1 DEF Doser #1 Temperature : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
4337-4
Aftertreatment #1 SCR Dosing Reagent Temperature : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Passive) - Test"
4337-15
Aftertreatment #1 DEF Doser #1 Temperature : High - least severe (1) Troubleshooting, "Manifold DEF Temperature Is High"
4337-17
Aftertreatment #1 DEF Doser #1 Temperature : Low - least severe (1) Troubleshooting, "Manifold DEF Temperature Is Low"
4337-18
Aftertreatment #1 DEF Doser #1 Temperature : Low - moderate severity (2) Troubleshooting, "Manifold DEF Temperature Is Low"
4354-5
Aftertreatment #1 DEF Line Heater #1 : Current Below Normal
High Side Troubleshooting, "Solenoid Valve - Test"
4354-6
Aftertreatment #1 DEF Line Heater #1 : Current Above Normal
High Side Troubleshooting, "Solenoid Valve - Test"
4355-5
Aftertreatment #1 DEF Line Heater #2 : Current Below Normal
Low Side Troubleshooting, "Solenoid Valve - Test"
4355-6
Aftertreatment #1 DEF Line Heater #2 : Current Above Normal
Low Side Troubleshooting, "Solenoid Valve - Test"
4357-5
Aftertreatment #1 DEF Line Heater #4 : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
4357-6
Aftertreatment #1 DEF Line Heater #4 : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
4358-3
Aftertreatment #1 SCR Catalyst Exhaust Gas Differential Pressure : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4358-4
Aftertreatment #1 SCR Catalyst Exhaust Gas Differential Pressure : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4360-3
Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4360-4
Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4363-3
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4363-4
Aftertreatment #1 SCR Catalyst Outlet Gas Temperature : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
4376-5
Aftertreatment #1 DEF Return Valve : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
4376-6
Aftertreatment #1 DEF Return Valve : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
4792-14
Aftertreatment #1 SCR System : Special Instruction Troubleshooting, "SCR Catalyst Sulfation Is Excessive"
5706-5
Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Below Normal Troubleshooting, "Solenoid Valve - Test"
5706-6
Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Above Normal Troubleshooting, "Solenoid Valve - Test"
6806-9
ECU Interface Mismatch : Abnormal Update Rate Troubleshooting, "Data Link - Test"
6875-3
Aftertreatment #1 DEF Dosing Pressure : Voltage Above Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
6875-4
Aftertreatment #1 DEF Dosing Pressure : Voltage Below Normal Troubleshooting, "Sensor Signal (Analog, Active) - Test"
7343–31
SCR Inducement Override Renewal Required Troubleshooting, "SCR Inducement Emergency Override" Diagnostic Codes
Diagnostic codes alert the operator that a problem in the electronic system has been detected. Diagnostic codes are also used by the service technician
Parts stopper Mariner:
82857M
82857M STOPPER PLATE
7003207, 7004201, 7005201, 7005207, 7005227, 7008204, 7008208, 7008218EW, 7008226, 7008238, 7008247, 7008248, 7008305, 7008425, 7010209, 7015207, 7015307, 7015327, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028207,
81531M
81531M STOPPER
7020201, 7025200, 7025207NW, 7025500, 7028207, 7028527, 7030200, 7040202, 7040207, 7040208, 7040328, 7040507, 7040716, 7048207, 7048227, 7060507, 7060528
97756M
97756M STOPPER
7008204, 7008208, 7008218EW, 7008226, 7008425, 7010209, 7015529, 7020201, 7025200, 7025207NW, 7025207PW, 7025208CW, 7025500, 7026226, 7028527, 7030200, 7030205, 7030301, 7030320, 7040202, 7040206, 7040207PW, 7040208PW, 7040706, 7040716, 7048227, 7048