55422 Mariner STUD, (#10-32 x 2.00), PANEL TO BOAT


55422 STUD, (#10-32 x 2.00), PANEL TO BOAT Mariner 7060507, 7060528, 71354120D, 7135417PD, 7135D73ZY, 7175412PD, 7175413PD, 7200412PD, 7200D73IY, 7200D73MD, 7200D73RD, 7200D73ZY, 7225E73MD, 7250422PD, 7F08261DF, 7F10203HD, 7F13203UB, 7F15201GD STUD

Buy STUD, (#10-32 x 2.00), PANEL TO BOAT 55422 Mariner genuine, new aftermarket parts with delivery
Number on catalog scheme: 57
 

Mariner entire parts catalog list:

7060507 1977
7060528 1978
71354120D 1990,1991
7135417PD 1989
7135D73ZY 2006
7175412PD 1989
7175413PD 1989,1990
7200412PD 1989,1990
7200D73IY 2006
7200D73MD 2003
7200D73RD 2004,2005,2006
7200D73ZY 2006
7225E73MD 2003,2004
7250422PD 1989,1990,1991,1992,1993,1994
7F08261DF 1995,1996,1997,1998
7F10203HD 1999,2000,2001,2002,2003,2004,2005
7F13203UB 2006
7F15201GD 1998

Information:


Table 1
Diagnostic Codes Table    
Code and Description    Conditions which Generate this Code    System Response    
262-3 5 Volt Sensor DC Power Supply voltage above normal     The analog sensor supply voltage is above normal for two seconds.
The Electronic Control Module (ECM) has been powered for three seconds.     The code is logged.
All sensors are set to default values.    
262-4 5 Volt Sensor DC Power Supply voltage below normal     The analog sensor supply voltage is below normal for two seconds.
The ECM has been powered for three seconds.    System OperationThe ECM supplies a regulated voltage of 5.0 0.2 VDC to the following sensors:
Atmospheric pressure sensor
Coolant temperature sensor
Engine oil pressure sensor
Fuel temperature sensor
Intake manifold air temperature sensor
Right turbocharger inlet pressure sensor
Turbocharger outlet pressure sensorThe supply voltage for the sensors is routed from the ECM to terminal A of each sensor connector. The sensor return for the sensors is routed from the ECM to terminal B of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.Note: The sensors are not protected from overvoltage. A short from the supply line to the +Battery may damage the sensors. If the -3 diagnostic code is active, it is possible that a sensor has been damaged. Repair the sensor supply and check for any active sensor diagnostic codes in order to determine if a sensor has failed.
Illustration 1 g01409385
Typical schematicTest Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF position.
Remove electrical power from the ECM.
Illustration 2 g01139425
ECM (1) J1/P1 connectors (2) J2/P2 connectors
Thoroughly inspect the J2/P2 ECM connector. Inspect all of the connectors that are associated with the circuit.Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 3 g01409630
P2 ECM connector (P2-30) Sensor return (P2-36) Sensor supply
Illustration 4 g01159881
Sensor connector (A) +5 V sensor supply (B) Sensor return (C) Signal
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and wiring for abrasion and for pinch points from the sensors back to the ECM.Expected Result:All connectors, pins and sockets are completely coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and connectors appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Check for Active Diagnostic Codes
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Restore electrical power to the ECM.
Turn the keyswitch to the ON position.
Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes. Look for the following diagnostic codes:
262-3
262-4 Note: Wait at least 30 seconds in order for the diagnostic codes to become active.Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic code is active.Repair: The problem is no longer present. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - A 262-3 or 262-4 diagnostic code is active at this time. Proceed to Test Step 3.Test Step 3. Disconnect the 5 Volt Sensor(s) while you Monitor the Active Diagnostic Codes
Monitor the active diagnostic code screen on Cat ET while you disconnect each 5 Volt sensor at the sensor connector. Check for an active 262-3 code or an active 262-4 code.Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Disconnect the following sensors one at a time:
Atmospheric pressure sensor
Coolant temperature sensor
Engine oil pressure sensor
Fuel temperature sensor
Intake manifold air temperature sensor
Right turbocharger inlet pressure sensor
Turbocharger outlet pressure sensorExpected Result:The diagnostic code deactivates when a particular sensor is disconnected.Results:
OK - The diagnostic code deactivates when a particular sensor is disconnected.Repair: Connect the suspect sensor. If the code returns, replace the sensor with a new sensor. Connect the connector(s). Verify that the problem is resolved.STOP
Not OK - The diagnostic code remains active after a sensor is disconnected. Leave the sensor disconnected. The sensor is not the cause of the diagnostic code. Proceed to Test Step 4.Test Step 4. Check the +5 V Supply Voltages at the ECM
Turn the keyswitch to the OFF position.
Disconnect the J2/P2 ECM connector.
Fabricate jumper wires that are long enough to be used to measure the supply voltages at the ECM connector. Crimp connector sockets to one end of each jumper wire.
Remove the wires from terminal locations P2-36 (+5 V sensor supply) and P2-30 (sensor return). Install a jumper wire into each of these terminal locations.
Reconnect the J2/P2 ECM connector.
Turn the keyswitch to the ON position.
Measure the voltage between the jumper wire in P2-36 (+5 V sensor supply) and the jumper wire in P2-30 (sensor return).
Turn the keyswitch to the OFF position.Expected Result:The voltage measurement is 5.0 0.2 VDC.Results:
OK - The voltage measurement is 5.0 0.2 VDC. The ECM is operating correctly.Repair: There is a problem with the harness. Repair the harness or replace the harness.STOP
Not OK - The voltage measurement is not 5.0 0.2 VDC.Repair: Replace the ECM. Refer to Troubleshooting, "ECM - Replace".STOP


Parts stud Mariner:

81387M
 
81387M STUD, CLAMP BRACKET
7040207, 7040208, 7040328, 7040507, 7048207, 7048227, 7048321, 7060507, 7060522, 7060528
81383M
 
81383M STUD, CLAMP BRACKET
7048207, 7048227, 7048321, 7055324, 7055524, 7060507, 7060522, 7060528
57920
 
57920 STUD, GEAR HOUSING TO DRIVE SHAFT HOUSING (2 1/16")
7075524, 7080508, 7080629, 7085507, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 71354120D, 7135417PD, 7135826, 7140528, 7140629, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175413AD, 7175413PD, 7175413YD, 7175629, 7200412PD, 7200620, 7220727
56297
 
56297 STUD, WATER PUMP BASE AND BODY TO GEAR HOUSING(3 3/8")
7002201DK, 7075524, 7080508, 7080629, 7085507, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 71354120D, 7135412AD, 7135412ED, 7135417PD, 7135826, 7140528, 7140629, 7150413ED, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175413AD, 7175413PD, 717
825522
STUD
825522 STUD
7F08203HF, 7F08261DF
827317
 
827317 STUD
7F08203HF, 7F08261DF
78638 2
 
78638 2 STUD, (.437-14/.437-20 x 3.120)
7115473JD, 7135412ED, 7135412HD, 7135412JD, 7135473GD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413ED, 7150413HD, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7150423JD, 7175423HD, 7200413JD, 7200413UY, 7200413ZY, 7200423UY
854819
STUD, (M10 x 1.5 x 97)
854819 STUD, (M10 x 1.5 x 97)
7F10203HD, 7F13203UB, 7F15201GD
Back to top