5772A 2 Mariner SWITCH BOX ASSEMBLY


5772A 2 SWITCH BOX ASSEMBLY Mariner 7045217, 7050200, 7050716, 7075524 SWITCH
5772A 2 SWITCH BOX ASSEMBLY Mariner
Rating:
93

Buy SWITCH BOX ASSEMBLY 5772A 2 Mariner genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$94.88

25-11-2024
10.0[4.50] pounds
US: Rareelectrical
RAREELECTRICAL New Starter Compatible With Mercury Marine 225Cxxl 225L225xl 225Xxl Dfi 50-833153-1 50-833153-2
Rareelectrical Rareelectrical Brand Compatible with MERCURY. Please verify your OEM part number from your original unit to help ensure fitment. || Replaces: Api Marine: Mot3016 / Mercury Marine: 50-833153 50-833153-1 50-833153-2 50-833153-5 50-833153-T4 / Item Description: Starter / Unit Type: Mercury / Type: Pmdd / Voltage: 12 / Rotation: Counterclockwise / Tooth Count: 9 / Gear Od: 21.8Mm / 0.858In / Mounting Ear 1: 8.0Mm Id Unthreaded / Mounting Ear 2: 8.0Mm Id Unthreaded / Weight: 8.9 Lbs / 4.05 Kg || Applications: Please Verify Your Oem Part Number From Your Original Unit To Help Ensure Fitment. / Mercury Marine 135Cxl Dfi / Optimax 99 2.5L - 153.0Ci - 135 H.P. Match Oe #50-833153-2 / Mercury Marine 135Cxl Dfi / Optimax 99 2.5L - 153.0Ci - 135 H.P. Match Oe #50-833153-5 / Mercury Marine 135Cxl Dfi / Optimax 98 2.5L - 153.0Ci - 135 H.P. United Tech System / Mercury Marine 135L Dfi / Optimax 99 2.5L - 153.0Ci - 135 H.P. Match Oe #50-833153-2 / Mercury Marine 135L Dfi / Optimax 99 2.5L - || Applications: - 135 H.P. Match Oe #50-833153-5 / Mercury Marine 135L Dfi / Optimax 98 2.5L - 153.0Ci - 135 H.P. United Tech System / Mercury Marine 135Xl Dfi / Optimax 99 2.5L - 153.0Ci - 135 H.P. Match Oe #50-833153-2 / Mercury Marine 135Xl Dfi / Optimax 99 2.5L - 153.0Ci - 135 H.P. Match Oe #50-833153-5 / Mercury Marine 135Xl Dfi / Optimax 98 2.5L - 153.0Ci - 135 H.P. United Tech System / Mercury Marine 150Cxl Dfi / Optimax 99 2.5L - 153.0Ci - 150 H.P. Match Oe #50-833153-2 / Mercury Marine || Starter - Voltage: 12V Rotation: Counterclockwise Teeth On Drive / Splines: 9 Country Of Origin: TW Source: Aftermarket
Number on catalog scheme: 24
 

Compatible models:

Mariner entire parts catalog list:

7045217 1987,1988,1989
7050200 1980,1982,1983,1985,1986
7050716 1986
7075524 1984,1985,1986

Information:


Table 1
Diagnostic Trouble Codes
J1939 Code CDL Code Code Description
(code descriptions may vary Comments
105-3 172-3 Engine Intake Manifold #1 Temperature : Voltage Above Normal The Electronic Control Module (ECM) detects the following conditions:
The signal voltage from the intake manifold air temperature sensor is greater than 4.95 VDC for more than 8 seconds.
Engine coolant temperature is above −10 °C (15.0 °F).
The ECM will use the default value of 70 °C (158 °F) for the intake manifold air temperature. "Voltage High" will be displayed next to the status for "Intake Manifold Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
105-4 172-4 Engine Intake Manifold #1 Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the intake manifold air temperature sensor is less than 0.2 VDC for more than 8 seconds.
The ECM will use the default value of 70 °C (158°F) for the intake manifold air temperature. "Voltage Low" will be displayed next to the status for "Intake Manifold Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
110-3 110-3 Engine Coolant Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the engine coolant temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Above Normal" will be displayed next to the status for "Engine Coolant Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
White smoke
110-4 110-4 Engine Coolant Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the engine coolant temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Below Normal" will be displayed next to the status for "Engine Coolant Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
White smoke
441-3 1836-3 Auxiliary Temperature #1 : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the auxiliary temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Above Normal" will be displayed next to the status for "Auxiliary Temperature" on the electronic service tool.
441-4 1836-4 Auxiliary Temperature #1 : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the auxiliary temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Below Normal" will be displayed next to the status for "Auxiliary Temperature" on the electronic service tool.
2630-3 3372-3 Engine Charge Air Cooler Outlet Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the ATAAC outlet temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Above Normal" will be displayed next to the status for "ATAAC Temperature" on the electronic service tool.
2630-4 3372-4 Engine Charge Air Cooler Outlet Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the ATAAC outlet temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
"Voltage Below Normal" will be displayed next to the status for "ATAAC Temperature" on the electronic service tool.
- 171-4 Ambient Air Temperature Sensor voltage below normal The ECM detects the following conditions:
The signal voltage from the ambient air temperature sensor is less than 0.2 VDC for more than 8 seconds.
"Voltage Low" will be displayed next to the status for "Ambient Air Temperature" on the electronic service tool.
The engine may show the following symptoms:
Poor stability
Poor cold running
Poor acceleration under load
White smoke
- 600-3 Hydraulic Oil Temperature Sensor voltage above normal The ECM detects the following conditions:
The signal voltage from the hydraulic oil temperature sensor is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Above Normal" will be displayed next to the status for "Hydraulic Oil Temperature" on the electronic service tool.
- 600-4 Hydraulic Oil Temperature Sensor voltage below normal The ECM detects the following conditions:
The signal voltage from the hydraulic oil temperature sensor is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Below Normal" will be displayed next to the status for "Hydraulic Oil Temperature" on the electronic service tool.
Follow the troubleshooting procedure in order to identify the root cause of the fault. Note: The following conditions must exist before any of the above codes will become active:
The ECM has been powered for at least 2 seconds.
There are no active 168-X diagnostic codes.The ECM will log the diagnostic code. If equipped, the warning light will come on.The following background information is related to this procedure:The troubleshooting procedures for the diagnostic codes of each temperature sensor are identical. The temperature sensors have two terminals. The signal line is connected to each sensor connector terminal 1. Terminal 2 is the return


Parts switch Mariner:

45326A 2
 
45326A 2 SWITCH ASSEMBLY
7045217, 7050200, 7050716, 7060312PC, 7060507, 7060524, 7060528, 7070520, 7080629, 7090520, 7090529, 7115520, 7115528, 7115529, 7140528, 7140629
33386A 3
 
33386A 3 SWITCH ASSEMLBY
7045217, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070520, 7090520, 7090524, 7115520, 71354120D, 7135417PD, 7135826, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175413PD, 7175413YD, 7175629, 7200412PD, 7200620, 7220727, 7250422PD
58124A20
74605A 4
 
74605A 4 SWITCH ASSEMBLY, NEUTRAL START
7045217, 7050200, 7050716
7778A 3
 
7778A 3 SWITCH BOX ASSEMLBY
7050716, 7060312PC, 7060524, 7070520, 7075717, 7090520, 7115520
Back to top