Information:
Fuel System
Duplex Fuel Filter System
CONTROL LEVER IN "FLOW BOTH" POSITIONThe duplex fuel filter system makes it possible to change filter elements when the engine is in operation without a shutdown.When the fuel pressure gauge indicator is in the RED range, the fuel filters must be changed.The steps that follow give instructions for the operation of the duplex fuel system.1. With lever at "AUX. RUN" position, start engine. Left gauge should indicated full pressure. Right gauge should indicate no pressure.2. With lever at "LH FLOW - RH FILL" position, left gauge should indicate full pressure. Within five minutes running, the right gauge should indicate a very small amount of pressure.3. With lever at "FLOW BOTH" position, both gauges should indicate full pressure. Look for leaks.4. With lever at "RH FLOW - LH FILL" position, left gauge should indicate a very small amount of pressure. Right gauge should indicate full pressure.5. With lever at "MAIN RUN" position, left gauge should indicate no pressure. Right gauge should indicate full pressure.6. The lever should be in the "MAIN RUN" position for normal operation.Governor Air Actuator
AIR ACTUATOR
1. Actuator.Governor air actuator (1) gives remote control of engine rpm. Air pressure through orifice (2) controls the movement of plunger (3) and rod (5) against spring (4). Rod (5) is connected to the terminal shaft of the governor by linkage. An increase in air pressure moves the rod out to increase rpm. Spring (6) permits the manual control lever to move the terminal shaft instead of the actuator. The diaphragm can be inspected or replaced without a change to the high or low idle speed of the engine.
AIR ACTUATORS
2. Orifice. 3. Plunger. 4. Spring. 5. Rod. 6. Spring.Wiring Diagrams
Many types of electrical systems are available for these engines. Some charging systems use an alternator and a regulator in the wiring circuit. Others have the regulator inside the alternator.A fuel or oil pressure switch is used in all systems with an external regulator. The switch prevents current discharge (field excitation) to alternator from the battery when the engine is not in operation. In systems where the regulator is part of the alternator, the transistor circuit prevents current discharge to the alternator and the fuel or oil pressure switch is not required.All wiring schematics are usable with 12, 24, 30 or 32 volts unless the title gives a specific description. Wire and cable shown dotted on wiring diagrams is to be supplied by customer. The chart that follows gives the correct wire sizes and color codes. The abbreviations given below are used with the wiring diagrams in this section. Abbreviations Grounded Electrical Systems
These systems are used in applications when it is not necessary to prevent radio distortion and/or chemical changes (electrolysis) of grounded components.(Regulator Inside Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Alternator. 3. Battery.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Alternator. 4. Battery. 5. Starter motor.(Regulator Separate From Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Regulator. 3. Pressure switch (N.O.). 4. Resistor (used with 30 and 32V systems). 5. Battery. 6. Alternator.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Regulator. 4. Resistor (for 30 and 32V systems). 5. Battery. 6. Starter motor. 7. Pressure switch (N.O.). 8. Alternator.
CHARGING SYSTEM WITH TWO ELECTRIC STARTER MOTORS
1. Magnetic switch. 2. Start switch. 3. Ammeter. 4. Regulator. 5. Resistor (for 30 and 32V systems). 6. Battery. 7. Starter motors. 8. Pressure switch (N.O.). 9. Alternator.The following diagrams are for use only when an alternator or charging generator is not used in the engine electrical system.
SYSTEM WITH ONE STARTER MOTOR
1. Start switch. 2. Starter motor. 3. Battery.
SYSTEMS WITH TWO STARTER MOTORS
1. Start switch. 2. Magnetic switch. 3. Battery. 4. Starter motors.Insulated Electrical Systems
These systems are most often used in applications where radio interference is not desired or where conditions are such that grounded components will have corrosion from chemical change (electrolysis).(Regulator Inside Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Alternator. 3. Battery.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Alternator. 4. Battery. 5. Starter motor.(Regulator Separate From Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Regulator. 3. Pressure switch (N.O.). 4. Resistor (used with 30 and 32V systems). 5. Battery. 6. Alternator.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Regulator. 4. Resistor (for 30 and 32V systems). 5. Battery. 6. Starter motor. 7. Pressure switch (N.O.). 8. Alternator.
CHARGING SYSTEM WITH TWO ELECTRIC STARTER MOTORS
1. Magnetic switch. 2. Start switch. 3. Ammeter. 4. Regulator. 5. Resistor (for 30 and 32V systems). 6. Battery. 7. Starter motors. 8. Pressure switch (N.O.). 9. Alternator.The following diagrams are for use only when an alternator or charging generator is not used in the engine electrical system.
SYSTEM WITH ONE STARTER MOTOR
1. Start switch. 2. Starter motor. 3. Battery.
SYSTEM WITH TWO STARTER MOTORS
1. Start switch. 2. Magnetic switch. 3. Battery. 4. Starter motors.Electric Tachometer Wiring
WIRING DIAGRAMS 1. Magnetic pickup.2. Terminal Connections - terminals 18 and 19 on load sharing governor control and terminals 7 and 8 on standby governor control.3. Tachometer.4. Ground connection - governor control chassis ground.5. Governor control terminal strip.6. Wiring connections - for second tachometer circuit if needed.7. All wire must be 22AWG shielded cable or larger.8. Dual speed switch terminal strip.9. Ground connection - ground to engine.Automatic Start/Stop System - (Non-Package Generator Sets)
AUTOMATIC START/STOP SYSTEM SCHEMATIC (Hydraulic Governor)
1. Starter motor and solenoid. 2. Shutoff solenoid. 3. Fuel pressure switch. 4. Water temperature switch. 5. Oil pressure switch. 6. Overspeed contactor. 7. Battery. 8. Low lubricating oil pressure light (OPL). 9. Overcrank light (OCL). 10. Overspeed light (OSL). 11. High water temperature light (WTL). 12. Automatic control switch (ACS).An automatic start/stop system is used when a standby electric set has to give power to a system if t
Duplex Fuel Filter System
CONTROL LEVER IN "FLOW BOTH" POSITIONThe duplex fuel filter system makes it possible to change filter elements when the engine is in operation without a shutdown.When the fuel pressure gauge indicator is in the RED range, the fuel filters must be changed.The steps that follow give instructions for the operation of the duplex fuel system.1. With lever at "AUX. RUN" position, start engine. Left gauge should indicated full pressure. Right gauge should indicate no pressure.2. With lever at "LH FLOW - RH FILL" position, left gauge should indicate full pressure. Within five minutes running, the right gauge should indicate a very small amount of pressure.3. With lever at "FLOW BOTH" position, both gauges should indicate full pressure. Look for leaks.4. With lever at "RH FLOW - LH FILL" position, left gauge should indicate a very small amount of pressure. Right gauge should indicate full pressure.5. With lever at "MAIN RUN" position, left gauge should indicate no pressure. Right gauge should indicate full pressure.6. The lever should be in the "MAIN RUN" position for normal operation.Governor Air Actuator
AIR ACTUATOR
1. Actuator.Governor air actuator (1) gives remote control of engine rpm. Air pressure through orifice (2) controls the movement of plunger (3) and rod (5) against spring (4). Rod (5) is connected to the terminal shaft of the governor by linkage. An increase in air pressure moves the rod out to increase rpm. Spring (6) permits the manual control lever to move the terminal shaft instead of the actuator. The diaphragm can be inspected or replaced without a change to the high or low idle speed of the engine.
AIR ACTUATORS
2. Orifice. 3. Plunger. 4. Spring. 5. Rod. 6. Spring.Wiring Diagrams
Many types of electrical systems are available for these engines. Some charging systems use an alternator and a regulator in the wiring circuit. Others have the regulator inside the alternator.A fuel or oil pressure switch is used in all systems with an external regulator. The switch prevents current discharge (field excitation) to alternator from the battery when the engine is not in operation. In systems where the regulator is part of the alternator, the transistor circuit prevents current discharge to the alternator and the fuel or oil pressure switch is not required.All wiring schematics are usable with 12, 24, 30 or 32 volts unless the title gives a specific description. Wire and cable shown dotted on wiring diagrams is to be supplied by customer. The chart that follows gives the correct wire sizes and color codes. The abbreviations given below are used with the wiring diagrams in this section. Abbreviations Grounded Electrical Systems
These systems are used in applications when it is not necessary to prevent radio distortion and/or chemical changes (electrolysis) of grounded components.(Regulator Inside Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Alternator. 3. Battery.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Alternator. 4. Battery. 5. Starter motor.(Regulator Separate From Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Regulator. 3. Pressure switch (N.O.). 4. Resistor (used with 30 and 32V systems). 5. Battery. 6. Alternator.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Regulator. 4. Resistor (for 30 and 32V systems). 5. Battery. 6. Starter motor. 7. Pressure switch (N.O.). 8. Alternator.
CHARGING SYSTEM WITH TWO ELECTRIC STARTER MOTORS
1. Magnetic switch. 2. Start switch. 3. Ammeter. 4. Regulator. 5. Resistor (for 30 and 32V systems). 6. Battery. 7. Starter motors. 8. Pressure switch (N.O.). 9. Alternator.The following diagrams are for use only when an alternator or charging generator is not used in the engine electrical system.
SYSTEM WITH ONE STARTER MOTOR
1. Start switch. 2. Starter motor. 3. Battery.
SYSTEMS WITH TWO STARTER MOTORS
1. Start switch. 2. Magnetic switch. 3. Battery. 4. Starter motors.Insulated Electrical Systems
These systems are most often used in applications where radio interference is not desired or where conditions are such that grounded components will have corrosion from chemical change (electrolysis).(Regulator Inside Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Alternator. 3. Battery.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Alternator. 4. Battery. 5. Starter motor.(Regulator Separate From Alternator)
CHARGING SYSTEM
1. Ammeter. 2. Regulator. 3. Pressure switch (N.O.). 4. Resistor (used with 30 and 32V systems). 5. Battery. 6. Alternator.
CHARGING SYSTEM WITH ELECTRIC STARTER MOTOR
1. Start switch. 2. Ammeter. 3. Regulator. 4. Resistor (for 30 and 32V systems). 5. Battery. 6. Starter motor. 7. Pressure switch (N.O.). 8. Alternator.
CHARGING SYSTEM WITH TWO ELECTRIC STARTER MOTORS
1. Magnetic switch. 2. Start switch. 3. Ammeter. 4. Regulator. 5. Resistor (for 30 and 32V systems). 6. Battery. 7. Starter motors. 8. Pressure switch (N.O.). 9. Alternator.The following diagrams are for use only when an alternator or charging generator is not used in the engine electrical system.
SYSTEM WITH ONE STARTER MOTOR
1. Start switch. 2. Starter motor. 3. Battery.
SYSTEM WITH TWO STARTER MOTORS
1. Start switch. 2. Magnetic switch. 3. Battery. 4. Starter motors.Electric Tachometer Wiring
WIRING DIAGRAMS 1. Magnetic pickup.2. Terminal Connections - terminals 18 and 19 on load sharing governor control and terminals 7 and 8 on standby governor control.3. Tachometer.4. Ground connection - governor control chassis ground.5. Governor control terminal strip.6. Wiring connections - for second tachometer circuit if needed.7. All wire must be 22AWG shielded cable or larger.8. Dual speed switch terminal strip.9. Ground connection - ground to engine.Automatic Start/Stop System - (Non-Package Generator Sets)
AUTOMATIC START/STOP SYSTEM SCHEMATIC (Hydraulic Governor)
1. Starter motor and solenoid. 2. Shutoff solenoid. 3. Fuel pressure switch. 4. Water temperature switch. 5. Oil pressure switch. 6. Overspeed contactor. 7. Battery. 8. Low lubricating oil pressure light (OPL). 9. Overcrank light (OCL). 10. Overspeed light (OSL). 11. High water temperature light (WTL). 12. Automatic control switch (ACS).An automatic start/stop system is used when a standby electric set has to give power to a system if t
Parts washer Mariner:
29245
29245 WASHER, UPPER MOUNT BRACKET
7001200, 7002201DK, 7006201CD, 7006201HB, 7006201TB, 7008218EW, 7008237, 7010207HB, 7010312DT, 7011201TB, 7015201LD, 70152374D, 7020201HB, 7020201NC, 7020201TB, 7020207, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 70404119D, 7041203GB, 70432037D, 704
89302
89302 WASHER, WATER PUMP SCEW
7001804, 7002201DK, 7020201NC, 7020207, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 70404119D, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7055207GD, 7055207HB, 7
28421
28421 WASHER, UPPER AND LOWER BUSHING (OUTER)
7002201DK, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 70404119D, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7045217, 7050200, 7050302ED, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7050412YD, 7050716, 705
56681
56681 WASHER, HARNESS CLAMP SCREW
7002201DK, 7006201CD, 7006201HB, 7006201TB, 7008218EW, 7008237, 7010207HB, 7010312DT, 7011201TB, 7015201LD, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050302ED, 7050312TB,
38013
38013 WASHER, INPUT STUD
70404119D, 7045217, 7050200, 7050716, 7050717, 7060312PC, 7060524, 7070509, 7070520, 7075312ND, 7075524, 7075717, 7080508, 7080629, 7090520, 7090524, 7090529, 7115520, 7115528, 7115529, 7140528, 7140629
40022 17
40022 17 WASHER, CARBURETOR STUDS
7004201HB, 7004201UB, 7004211SK, 7006201MK, 7006201UK, 7015203KL, 7015203UL, 7025207UL, 7025217UL, 7030201KL, 7030201UL, 7030211U2, 7030A01UL, 7030A11UL, 7031207LF, 7040203KL, 7040203UL, 7075217CD, 7075217HD, 7075217TD, 7075217UD, 70752L7TF, 70752L7U
20722
812876
812876 WASHER
7002201DK, 7031203GD, 7031207CD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050302ED, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7050412YD, 7055207GD, 7055207HB, 7055207TF, 7060412E