61170 Mercruiser BEARING SET, CONNECTING ROD (STANDARD)


61170 BEARING SET, CONNECTING ROD (STANDARD) Mercruiser 44031854 BEARING
61170 BEARING SET, CONNECTING ROD (STANDARD) Mercruiser
Rating:
93

Buy BEARING SET, CONNECTING ROD (STANDARD) 61170 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 14
 

Compatible models:

44031854   Mercruiser

Mercruiser entire parts catalog list:

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
1761-3
Aftertreatment #1 DEF Tank Volume #1 : Voltage Above Normal 3130-3
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The code is logged.
1761-4
Aftertreatment #1 DEF Tank Volume #1 : Voltage Below Normal 3130-4
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-3
Aftertreatment #1 DEF Tank Temperature : Voltage Above Normal 3134-3
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-4
Aftertreatment #1 DEF Tank Temperature : Voltage Below Normal 3134-4
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-3
Aftertreatment #2 DEF Tank Volume #1 : Voltage Above Normal 3132-3
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-4
Aftertreatment #2 DEF Tank Volume #1 : Voltage Below Normal 3132-4
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-3
Aftertreatment #2 DEF Tank Temperature : Voltage Above Normal 3136-3
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-4
Aftertreatment #2 DEF Tank Temperature : Voltage Below Normal 3136-4
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-3
Aftertreatment #1 DEF Tank Volume #2 : Voltage Above Normal 5013-3
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-4
Aftertreatment #1 DEF Tank Volume #2 : Voltage Below Normal 5013-4
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-3
Aftertreatment #2 DEF Tank Volume #2 : Voltage Above Normal 5014-3
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-4
Aftertreatment #2 DEF Tank Volume #2 : Voltage Below Normal 5014-4
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-3
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Above Normal 5015-3
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-4
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Below Normal 5015-4
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal 5016-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal 5016-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged. The 5 V signal for the Diesel Exhaust Fluid (DEF) tank level sensor is routed to terminal 1 of the tank header unit. The 5 V signal for the DEF tank temperature sensor is routed to terminal 3 of the tank header unit. The sensor return is shared and is routed to terminal 2 of the tank header unit. The Electronic Control Module (ECM) provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.
Illustration 1 g06100987
Illustration 2 g06522892
(1) Aftertreatment #1 DEF pump #1 header (blue)
(2) Aftertreatment #1 DEF pump #2 header (green)
(3) Aftertreatment #2 DEF pump #1 header (yellow)
(4) Aftertreatment #2 DEF pump #2 header (red)
(5) Aftertreatment #1 DEF pump #1 (blue)
(6) Aftertreatment #1 DEF pump #2 (green)
(7) Aftertreatment #2 DEF pump #1 (yellow)
(8) Aftertreatment #2 DEF pump #2 (red)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Select the Diesel Exhaust Fluid Controller (DCU).
C. Determine if a code is active or logged.
Codes
Result: A -3 code is active or logged.
Proceed to Test Step 2.
Result: A -4 code is active or logged.
Proceed to Test Step 3.
2. Create a Short at the Affected Sensor Connector
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Install a jumper wire between the appropriate signal and return wire at the affected sensor connector to create a short.
C. Turn the keyswitch to ON.
D. Connect Cat ET.
E. Use Cat ET to monitor the following codes:
- -4 code
F. Turn the keyswitch to OFF.
Create a Short
Result: A -4 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional information.
If the problem is not resolved, proceed to Test Step 3.
Result: A -4 code does not become active.
Repair: Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 3.
3. Create an Open at the Affected Sensor Connector
A. Disconnect the connector of the affected tank header unit.
B. Turn the keyswitch to ON.
C. Connect Cat ET.
D. Use Cat ET to monitor the following codes:
- -3 code
E. Turn the keyswitch to OFF.
Create an Open
Result: A -3 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional info


Parts bearing Mercruiser:

85721
 
85721 BEARING UNIT, CRANKSHAFT (STANDARD)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85685
 
85685 BEARING UNIT, CRANKSHAFT MAIN (.001 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85723
 
85723 BEARING UNIT, CRANKSHAFT MAIN (.002 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85724
 
85724 BEARING UNIT, CRANKSHAFT MAIN (.010 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85725
 
85725 BEARING UNIT, CRANKSHAFT MAIN (.020 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85686
 
85686 BEARING UNIT, CRANKSHAFT MAIN - REAR (STANDARD)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85689
 
85689 BEARING UNIT, CRANKSHAFT MAIN - REAR (.010 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
85688
 
85688 BEARING UNIT, CRANKSHAFT MAIN - REAR (.002 USA)
03302336, 03307332, 03308333, 04544347, 06661346, 37011856, 44031854
Back to top