49213A 1 Mercruiser BELT, ALTERNATOR DRIVE (44")


49213A 1 BELT, ALTERNATOR DRIVE (44") Mercruiser 00014332, 01751347, 01851333, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 07711346, 08987343, 32001876 BELT
49213A 1 BELT, ALTERNATOR DRIVE (44") Mercruiser
Rating:
33

Buy BELT, ALTERNATOR DRIVE (44") 49213A 1 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 23
 

Information:


Table 1
Diagnostic Codes Table
J1939 Code and Description CDL Code and Description System Response
52-3
Engine Intercooler Temperature : Voltage Above Normal 279-3
Aftercooler Coolant Temperature Sensor (Front) : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to 90 °C (194 °F).
The engine will not enter cold mode while the code is active.
52-4
Engine Intercooler Temperature : Voltage Below Normal 279-4
Aftercooler Coolant Temperature Sensor (Front) : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to 90 °C (194 °F).
The engine will not enter cold mode while the code is active.
105-03
Engine Intake Manifold 1 Temperature : Voltage Above Normal 172-03
Intake Manifold Air Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be greater than −35 °C (−31 °F) to allow logging of this diagnostic code.
The value of the parameter is set to 85 °C (185 °F).
105-04
Engine Intake Manifold 1 Temperature : Voltage Below Normal 172-04
Intake Manifold Air Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be less than 140 °C (284 °F) to allow logging of this diagnostic code.
The value of the parameter is set to 85 °C (185 °F).
110-3
Engine Coolant Temperature : Voltage Above Normal 110-3
Engine Coolant Temperature Sensor : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged after 7 minutes.
The value of the parameter is set to 90 °C (194 °F).
The engine will not enter cold mode while the code is active.
110-4
Engine Coolant Temperature : Voltage Below Normal 110-4
Engine Coolant Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to 90 °C (194 °F).
The engine will not enter cold mode while the code is active.
172-3
Engine Air Inlet Temperature : Voltage Above Normal 2526-3
Air Inlet Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be greater than −35 °C (−31 °F) to allow logging of this diagnostic code.
The value of the parameter is set to the value of the intake manifold air temperature. If the value of the intake manifold air temperature is less than −30 °C (−22 °F), the value of the parameter is set to −40 °C (−40 °F).
172-4
Engine Air Inlet Temperature : Voltage Below Normal 2526-4
Air Inlet Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to the default value.
174-3
Engine Fuel Temperature 1 : Voltage Above Normal 174-3
Fuel Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Engine coolant temperature must be above −10 °C (14 °F) to allow logging of this diagnostic code.
The value of the parameter is set to the value of the engine coolant temperature.
174-4
Engine Fuel Temperature 1 : Voltage Below Normal 174-4
Fuel Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to the value of the engine coolant temperature.
175-3
Engine Oil Temperature 1 : Voltage Above Normal 175-3
Engine Oil Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be greater than −35 °C (−31 °F) to allow logging of this diagnostic code.
The value of the parameter is set to the value of the engine coolant temperature.
175-4
Engine Oil Temperature 1 : Voltage Below Normal 175-4
Engine Oil Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
The code is logged.
The value of the parameter is set to the value of the engine coolant temperature.
1131-3
Engine Intake Manifold #2 Temperature : Voltage Above Normal 1796-3
Intake Manifold #2 Air Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be greater than −35 °C (−31 °F) to allow logging of this diagnostic code.
The value of the parameter is set to 85 °C (185 °F).
1131-4
Engine Intake Manifold #2 Temperature : Voltage Below Normal 1796-4
Intake Manifold #2 Air Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be less than 140 °C (284 °F) to allow logging of this diagnostic code .
The value of the parameter is set to 85 °C (185 °F).
3468-3
Engine Fuel Temperature 2 : Voltage Above Normal 2323-3
Fuel Rail Temperature Sensor : Voltage Above Normal The ECM detects signal voltage that is greater than 4.95 VDC for 8 seconds.
The ECM has been powered for at least 2 seconds.
Ambient temperature must be greater than −35 °C (−31 °F) to allow logging of this diagnostic code.
The value of the parameter is set to the value of the engine


Parts belt Mercruiser:

49213
74271
 
74271 BELT, WATER PUMP
00014332, 02287333, 02297343, 02607333, 02608427, 03302336, 03307332, 04706002, 04707333, 08986342, 08987343, 228801, 260801, 37011856
48120
 
48120 BELT, DRIVE (46")
02287333, 02607333, 08986342, 228801, 260801
93658
 
93658 BELT, DRIVE (44") - HIGH MOUNTED P/S PUMP
02287333, 02607333, 08986342, 228801, 260801
13457T
 
13457T BELT, WATER PUMP (30")
02602347, 02608427, 03307332, 03308333, 04544347, 257B021JS, 4052110CR, 4350104JS, 4350111HS, 4350118JS, 443B100JS, 4454110AS, 4454118JT, 457B100KS, 457B101JS, 457B111GS, 457L101JS, 474H110AR, 474L111JS, 474L118JT
48120A 1
 
48120A 1 BELT (46") (USE WITH 7" DIA. REF #13)
01751347, 02602347, 02608427, 257B021JS, 4350104JS, 4350111HS, 4350118JS, 443B0002S, 443B1003S, 443B100JS, 457B100KS, 457B101JS, 457B111GS, 457L101JS
Back to top