71681 Mercruiser BOLT, CYLINDER HEAD TO CYLINDER BLOCK(3 15/16")


71681 BOLT, CYLINDER HEAD TO CYLINDER BLOCK(3 15/16") Mercruiser 2888203 BOLT
71681 BOLT, CYLINDER HEAD TO CYLINDER BLOCK(3 15/16") Mercruiser
Rating:
83

Buy BOLT, CYLINDER HEAD TO CYLINDER BLOCK(3 15/16") 71681 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 10
 

Compatible models:

2888203   Mercruiser

Mercruiser entire parts catalog list:

2888203 1973,1974,1975,1976,1977

Information:


Table 1
Diagnostic Codes
CDL Code and Description Conditions which Generate this Code System Response
3110-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1:Current Below Normal
Note: The code is for the supply side relay. The Electronic Control Module (ECM) detects an open in the circuit for the relay. The code is logged.
3110-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1:Current Above Normal
Note: The code is for the supply side relay. The ECM detects a short in the circuit for the relay. The code is logged.
3111-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2:Current Below Normal
Note: The code is for the return side relay. The Electronic Control Module (ECM) detects an open in the circuit for the relay. The code is logged.
3111-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2:Current Above Normal
Note: The code is for the return side relay. The ECM detects a short in the circuit for the relay. The code is logged.
Illustration 1 g03413650
DEF heated line circuit
(1) Connector for engine (A-C2)
(2) Connector for CEM (A-C3)
(3) Connector for tank (A-C13)
(4) Engine mounted connector (ED-C1)
Illustration 2 g03413759
DEF manifold heater circuit
In order to aid troubleshooting, overrides are provided via Cat ET.Overrides allow the technician to turn the circuit on and off at will.Refer to table 2 for the appropriate override for the code.
Table 2
Component Override
3110-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1:Current Below Normal
Note: The code is for the supply side relay. Aftertreatment #1 SCR Catalyst Reagent Line Heater #1 State Override
Note: The override is for the supply side relay.
3110-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #1:Current Above Normal
Note: The code is for the supply side relay.
3111-5
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2:Current Below Normal
Note: The code is for the return side relay. Aftertreatment #1 SCR Catalyst Reagent Line Heater #2 State Override
Note: The override is for the return side relay.
3111-6
Aftertreatment #1 SCR Catalyst Reagent Line Heater #2:Current Above Normal
Note: The code is for the return side relay. Test Step 1. Determine the Diagnostic Code
Establish communication between Cat ET and the ECM . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
Download the "Warranty Report" from the ECM before performing any troubleshooting or clearing diagnostic trouble codes. Wait at least 30 seconds in order for the diagnostic codes to become active.
Look for these active codes or logged codes:
-5
-6Results:
A -5 diagnostic code is active. - Proceed to Test Step 2.
A -6 diagnostic code is active. - Proceed to Test Step 3. Test Step 2. Check the Wiring for an Open Circuit
Verify that the harness connectors are free of debris, free of corrosion and securely connected.
Disconnect the harness from the relay.
Connect a jumper wire between the terminals of the harness connector for the suspect relay. The relay is replaced with a short circuit.
Clear the -5 code.
Activate the override for the suspect circuit. Refer to table 2 for the appropriate override for the code. Results:
A -5 code became active during the override. - The ECM did not detect the jumper wire. There is an open circuit in the wiring between the relay and the ECM connector. There may be a problem with a connector.Repair: Repair the appropriate harness wiring or replace the appropriate harness.Verify that the problem is resolved.STOP
A -6 code became active during the override. The ECM detected the jumper wire. There is a problem with the solenoid. - Repair: Replace the relay.Verify that the problem is resolved.STOPTest Step 3. Check the Wiring for a Short Circuit
Verify that the harness connectors are free of debris, free of corrosion and securely connected.
Disconnect the harness from the relay.
Clear the -6 code.
Activate the override for the suspect circuit. Refer to table 2 for the appropriate override for the code. Results:
A -6 code became active during the override. - The ECM did not detect the open circuit. There is a short circuit in the wiring between the relay and the ECM connector. There may be a problem with a connector.Repair: Repair the appropriate harness wiring or replace the appropriate harness. Verify that the problem is resolved.STOP
A -5 code became active during the override. - The ECM detected the open circuit. The wiring is OK. The solenoid has a short circuit.Repair: Replace the relay.Verify that the problem is resolved.STOP


Back to top