810826 Mercruiser CAM RETAINER


810826 CAM RETAINER Mercruiser 430B00001 CAM
810826 CAM RETAINER Mercruiser
Rating:
88

Buy CAM RETAINER 810826 Mercruiser genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$38.88
 

09-08-2022

-: -
NORTHERN PARTS HUB Top End Gasket Kit fits - AC 300 2x4 1998-2004 300cc 300 4x4 1998-2005 300cc 810826 - Rebuild Gasket Set - Repair Gaskets - Gasket Overhaul Kit
OVER 5,000 OPTIONS : Northern Parts Hub gasket kit, head gasket set, top end gasket kit and sealing gaskets fit both OLD and NEW models of lawn mowers, petrol cutters, trimmers, motorcycles, ATVs, cars, and agricultural machinery of most types. Check our STORE to find everything in one place. || COMPATIBLE: This Gasket Kit is intended for: 300 2x4 1998-2004 300cc 300 4x4 1998-2005 300cc 810826 || MAXIMUM ENGINE LIFE: Our rebuild gasket set will help keep your engines and power equipment running at their best for years to come. This means you save time and money on repairs and get outstanding performance from your equipment with minimal downtime and productivity loss. || EASY, SECURE INSTALLATION : Our full top gasket set, complete gasket kit, big bore gasket kit sensure your engine's excellent performance without leaks and with minimal idling adjustments or priming. || SERVICE and QUALITY PROMISE : Each gasket set is backed by outstanding service and EVERLASTING commitment. Order Northern Parts Hub gasket replacement kits with confidence!
$36.55
 

04-06-2023
0.2[0.09] Pounds
-: -
Vertex 810826 Top End Gasket Kit Compatible with/Replacement for Honda Yamaha
1-year warranty protects you after your purchase || 100% New aftermarket unit built to meet OEM specifications
$24.85
 

15-06-2020
0.4[0.00] Pounds
-: -
Quadboss Top End Gasket Set for 98-05 Arctic CAT 300-4X4
Chances are you're all too familiar with this question: What are you going to do with it? Whether it's your spouse, buddy, the powersport dealer, or even yourself that asked it, the number of answers are nearly limitless. || Your quad doesn't have to look like or perform like every other quad that came rolling off the assembly line. || You can MAKE IT YOURS. || Customize it to your specific needs. || Whatever your answer, QuadBoss is here to help.
Number on catalog scheme: 8
 

Compatible models:

430B00001   Mercruiser

Mercruiser entire parts catalog list:

430B00001 1990,1991,1992,1993,1994,1995

Information:

A Rating (Continuous)
* For heavy-duty service when engine is operated at rated load and speed up to 100 percent of the time without interruption or load cycling.* Time at full load up to 100 percent of the duty cycle.* Typical examples are: pipeline pumping, ventilation, and customer specifications.B Rating
* For servicing where power and/or speed are cyclic.* Time at full load not to exceed 80 percent of the duty cycle.* Typical examples are: irrigation where normal pump demand is 85 percent of the duty cycle, oil field mechanical pumping and drilling, and stationary/plant air compressors.C Rating (Intermittent)
* For service where power and/or speed are cyclic* The horsepower and speed capability of the engine can be used for one uninterrupted hour, followed by one hour of operation at or below the A rating.* Time at full load not to exceed 50 percent of the duty cycle.* Typical examples are: agricultural tractors, harvesters and combines, off-highway trucks, fire pump application power, blast hole drills, rock crushers and wood chippers with high torque rise, and oil field hoisting.D Rating
* For service when rated power is required for periodic overloads.* The maximum horsepower and speed capability of the engine can be used for a maximum of 30 uninterrupted minutes, followed by one hour of followed by one hour of C rating operation.* Time at full load not to exceed 10 percent of the duty cycle.* Typical examples are: offshore cranes, runway snow blowers, water well drills, portable air compressors, and fire pump certification power.E Rating
* For service where rated power is required for a short time for initial starting or sudden overload. For emergency service where standard power is unavailable.* The maximum horsepower and speed capability of the engine can be utilized for a maximum of 15 uninterrupted minutes, followed by one hour at C rating operation, or for the duration of the emergency.* Time at full load is not to exceed 5 percent of the duty cycle.* Typical examples are: standby centrifugal water pumps, oil field well servicing, crash trucks, and gas turbine starters.Rating Conditions
Unless otherwise specified, all ratings are based on SAE J1349 standard ambient conditions:* 100 kPa (29.6 inches of Hg) of pressure* 30 percent relative humidity, and* a temperature of 26°C (77°F).Ratings also apply at AS1501, BS5514, DIN6271, and ISO3046/1 standard conditions.Power for diesel engines is based on:* API gravity of 35 at 15°C (60°F),* fuel LHV of 42.780 kJ/g (18390 Btu/lb) at 29°C (84°F), and* fuel density of 838.9 g/L (7.0001 lb/US gal)Ratings are gross output ratings- the total output capability of the engine-equipped with standard accessories. Standard accessories include pumps for lubrication oil, fuel, and jacket water, and magneto as required. The gross output, minus the power required to drive auxiliary components, equals the net power available for the external (flywheel) load. Typical auxiliary components include cooling fans, air compressors, and charging alternators.Ratings must be reduced to compensate for altitude conditions, according to the applicable engine test specification derating data at normal ambient temperature.EPG Engine Ratings
All ratings shown are subject to manufacturing tolerances of plus or minus three percent.Standby Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 100.* Typical peak demand: 80 percent of the Standby rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical Application: Building Service Standby with enclosed sheltered environment.Prime Plus 10 Percent Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 500.* Typical peak demand: 80 percent of the Prime Plus 10 Percent rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical applications: Standby, Rental Unit, Power Module, Unreliable Utility, and Interruptible Rates.Prime Rating
* Typical load factor: 60 to 70 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated output is used for less than 10 percent of the operating hours.* Typical applications: Industrial, Pumping, Construction, Peak Shaving, and Cogeneration.Continuous Rating
* Typical load factor: 70 to 100 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated kW is used for less than 100 percent of the operating hours.* Typical application: Base Load, Utility, and Cogeneration.
Operating units above the rating definitions will result in shorter service life before overhaul.


Parts cam Mercruiser:

9048
 
9048 CAM, FAST IDLE
00014332, 01207333, 01402414, 01407333, 01701335, 01751347, 01854335, 02287333, 02602347, 02607333, 02608427, 04707333, 04708004, 08987343, 257B021JS, 4111021L1, 411102KN2, 4211015L1, 4211025RS, 430B00001, 430L000JS, 4350100KS, 443B0002S, 443B1003S,
Back to top