26953 PIN-COTTER Mercruiser
5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5C30150FS, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200T
PIN
Price: query
Rating:
Compatible models:
5120136JS
5120150R1
5231100LP
5231100TP
5232100N1
5232100TP
5C30150FS
5E31200N1
5E31200TP
5E31200TS
5E31210TP
5E31210TS
5E31800TP
5E31800TS
5E31810TP
5E31810TS
5E31900TP
5E31900TS
5E31910TP
5E31910TS
5E32200TP
5E32900TS
5E36200TP
5E36200TS
5E36210TP
5E36210TS
5E36800TP
5E36800TS
5E36810TP
5E36810TS
5E36900TS
5E36910TP
5E36910TS
5H41400TP
5H41410TP
5H41410TS
5H41600TP
5H41610TP
5H41610TS
5H42300TP
5H42300TS
5H42400TS
5M41400TP
5M41400TS
5M42300TP
5M42300TS
5T32300TP
5T32300TS
5X32200TS
6020006JS
6211001N1
6311002NZ
6315001N1
6315002NZ
6416003N2
6511102N1
6811001N1
Mercruiser
Mercruiser entire parts catalog list:
5120150R1 1998
5231100LP 1998
5231100TP 1998
5232100N1 1998
5232100TP 1998
5C30150FS 1993,1994,1995,1996,1997,1998
- DRIVE HOUSING AND COMPONENTS » 26953
5E31200TP 1998
5E31200TS 1998
5E31210TP 1998
5E31210TS 1998
5E31800TP 1998
5E31800TS 1998
5E31810TP 1998
5E31810TS 1998
5E31900TP 1998
5E31900TS 1998
5E31910TP 1998
5E31910TS 1998
5E32200TP 1998
5E32900TS 1998
5E36200TP 1998
5E36200TS 1998
5E36210TP 1998
5E36210TS 1998
5E36800TP 1998
5E36800TS 1998
5E36810TP 1998
5E36810TS 1998
5E36900TS 1998
5E36910TP 1998
5E36910TS 1998
5H41400TP 1998
5H41410TP 1998
5H41410TS 1998
5H41600TP 1998
5H41610TP 1998
5H41610TS 1998
5H42300TP 1998
5H42300TS 1998
5H42400TS 1998
5M41400TP 1998
5M41400TS 1998
5M42300TP 1998
5M42300TS 1998
5T32300TP 1998
5T32300TS 1998
5X32200TS 1998
6020006JS 1996,1997
- UNIVERSAL JOINT-SHIFTER COMPONENTS » 26953
- DRIVE HOUSING AND COMPONENTS » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS(X-DRIVE) » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS » 26953
- UNIVERSAL JOINT AND SHIFTER COMPONENTS(STANDARD) » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS(X-DRIVE) » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS » 26953
- UNIVERSAL JOINT AND SHIFTER COMPONENTS(STANDARD) » 26953
- UNIVERSAL JOINT AND SHIFT COMPONENTS » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS(X-DRIVE) » 26953
- UNIVERSAL JOINT AND SHIFTER COMPONENTS(STANDARD) » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS(X-DRIVE) » 26953
- UNIVERSAL JOINT-SHIFTER COMPONENTS » 26953
- UNIVERSAL JOINT AND SHIFT COMPONENTS » 26953
6511102N1 1998
6811001N1 1998
Information:
Procedure For Programming The Hourmeter
This procedure uses a new GSC with 0 hours as an example. The hourmeter in the new GSC will be set to a value of 1,234 hours. The value must be higher than the original value. Note: Service mode cannot be entered when the ECS is in the AUTO position. Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key six times. "OP 7" is showing on the lower display.
Press "SELECT" key. The present value for the hourmeter is showing.
. Press "SELECT" key. "000000" is showing and the first digit is flashing.
Press "SCROLL RIGHT" key two times. "000000" is showing and the third digit is flashing.
Press "SCROLL UP" key. "001000" is showing and the third digit is flashing.
Press "SCROLL RIGHT" key. "001000" is showing and the fourth digit is flashing.
. Press "SCROLL UP" key two times. "001200" is showing and the fourth digit is flashing.
Press "SCROLL RIGHT" key. "001200" is showing and the fifth digit is flashing.
Press "SCROLL UP" key three times. "001230" is showing and the fifth digit is flashing.
Press "SCROLL RIGHT" key. "001230" is showing and the sixth digit is flashing.
Press "SCROLL UP" key four times. "001234" is showing and the sixth digit is flashing.
Press "ENTER" key. "001234" flashes on the lower display and "ArE YOU SUrE" is showing on the upper display.
For "yes", press "ENTER" key. "001234" stops flashing.
For "no", press "SELECT" key. "000000" is showing and the first digit is flashing. Repeat this procedure to program the hourmeter again.Note: In order to exit this procedure without saving any changes, press the exit key twice when the display shows "ArE YOU SUrE". The GSC returns to the normal display. The original value for the hourmeter is kept in the memory of the GSC. Note: Lower hours cannot be entered into the GSC if the GSC has a value that is stored. the upper display briefly shows "Error". The display then shows the original hours that are stored in the GSC and the first digit is flashing.
Press "EXIT" key. "OP 1" is showing on lower display.
Press "EXIT" key. The display returns to the normal mode. The programmed value for the hourmeter should show on the lower display as the engine data scrolls.
This procedure uses a new GSC with 0 hours as an example. The hourmeter in the new GSC will be set to a value of 1,234 hours. The value must be higher than the original value. Note: Service mode cannot be entered when the ECS is in the AUTO position. Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key six times. "OP 7" is showing on the lower display.
Press "SELECT" key. The present value for the hourmeter is showing.
. Press "SELECT" key. "000000" is showing and the first digit is flashing.
Press "SCROLL RIGHT" key two times. "000000" is showing and the third digit is flashing.
Press "SCROLL UP" key. "001000" is showing and the third digit is flashing.
Press "SCROLL RIGHT" key. "001000" is showing and the fourth digit is flashing.
. Press "SCROLL UP" key two times. "001200" is showing and the fourth digit is flashing.
Press "SCROLL RIGHT" key. "001200" is showing and the fifth digit is flashing.
Press "SCROLL UP" key three times. "001230" is showing and the fifth digit is flashing.
Press "SCROLL RIGHT" key. "001230" is showing and the sixth digit is flashing.
Press "SCROLL UP" key four times. "001234" is showing and the sixth digit is flashing.
Press "ENTER" key. "001234" flashes on the lower display and "ArE YOU SUrE" is showing on the upper display.
For "yes", press "ENTER" key. "001234" stops flashing.
For "no", press "SELECT" key. "000000" is showing and the first digit is flashing. Repeat this procedure to program the hourmeter again.Note: In order to exit this procedure without saving any changes, press the exit key twice when the display shows "ArE YOU SUrE". The GSC returns to the normal display. The original value for the hourmeter is kept in the memory of the GSC. Note: Lower hours cannot be entered into the GSC if the GSC has a value that is stored. the upper display briefly shows "Error". The display then shows the original hours that are stored in the GSC and the first digit is flashing.
Press "EXIT" key. "OP 1" is showing on lower display.
Press "EXIT" key. The display returns to the normal mode. The programmed value for the hourmeter should show on the lower display as the engine data scrolls.
Parts pin Mercruiser:
821997
821997 PIN, Hinge, For Use Without Trim Senders
5120136JS, 5120150AR, 5220200AS, 5231100LP, 5C30150FS, 5E31200N1, 6020006JS, 6211001N1, 6311002NZ, 6315002NZ, 6416003N2, 6511102N1, 6811001N1
805256
805095
15878
15878 PIN, Clevis
4S42028N1, 4S42028TS, 4S42028TT, 4S42028UT, 4S42028UU, 4S420P8UE, 5000147JS, 5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810T
16419
16419 PIN, Clevis
4S42028N1, 4S42028TS, 4S42028TT, 4S42028UT, 4S42028UU, 4S420P8UE, 5000147JS, 5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810T
78310
78310 PIN TOOL, Hinge
5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200T
840728
840728 PIN, Mounting
5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200TP, 5E36200TS, 5E36210TP, 5E36210TS, 5E36800TP, 5E36800TS, 5E36810TP, 5E36810T
840832
840832 PIN
5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200TP, 5E36200TS, 5E36210TP, 5E36210TS, 5E36800TP, 5E36800TS, 5E36810TP, 5E36810T