26953 Mercruiser PIN-COTTER


26953 PIN-COTTER Mercruiser 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5C30150FS, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200T PIN
26953 PIN-COTTER Mercruiser
Rating:
93

Buy PIN-COTTER 26953 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 19
 

Mercruiser entire parts catalog list:

5120136JS 1996,1997,1998
5120150R1 1998
5231100LP 1998
5231100TP 1998
5232100N1 1998
5232100TP 1998
5C30150FS 1993,1994,1995,1996,1997,1998
5E31200N1 1998
5E31200TP 1998
5E31200TS 1998
5E31210TP 1998
5E31210TS 1998
5E31800TP 1998
5E31800TS 1998
5E31810TP 1998
5E31810TS 1998
5E31900TP 1998
5E31900TS 1998
5E31910TP 1998
5E31910TS 1998
5E32200TP 1998
5E32900TS 1998
5E36200TP 1998
5E36200TS 1998
5E36210TP 1998
5E36210TS 1998
5E36800TP 1998
5E36800TS 1998
5E36810TP 1998
5E36810TS 1998
5E36900TS 1998
5E36910TP 1998
5E36910TS 1998
5H41400TP 1998
5H41410TP 1998
5H41410TS 1998
5H41600TP 1998
5H41610TP 1998
5H41610TS 1998
5H42300TP 1998
5H42300TS 1998
5H42400TS 1998
5M41400TP 1998
5M41400TS 1998
5M42300TP 1998
5M42300TS 1998
5T32300TP 1998
5T32300TS 1998
5X32200TS 1998
6020006JS 1996,1997
6211001N1 1998
6311002NZ 1998
6315001N1 1998
6315002NZ 1998
6416003N2 1998
6511102N1 1998
6811001N1 1998

Information:

Procedure For Programming The Hourmeter
This procedure uses a new GSC with 0 hours as an example. The hourmeter in the new GSC will be set to a value of 1,234 hours. The value must be higher than the original value. Note: Service mode cannot be entered when the ECS is in the AUTO position. Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key six times. "OP 7" is showing on the lower display.
Press "SELECT" key. The present value for the hourmeter is showing.
. Press "SELECT" key. "000000" is showing and the first digit is flashing.
Press "SCROLL RIGHT" key two times. "000000" is showing and the third digit is flashing.
Press "SCROLL UP" key. "001000" is showing and the third digit is flashing.
Press "SCROLL RIGHT" key. "001000" is showing and the fourth digit is flashing.
. Press "SCROLL UP" key two times. "001200" is showing and the fourth digit is flashing.
Press "SCROLL RIGHT" key. "001200" is showing and the fifth digit is flashing.
Press "SCROLL UP" key three times. "001230" is showing and the fifth digit is flashing.
Press "SCROLL RIGHT" key. "001230" is showing and the sixth digit is flashing.
Press "SCROLL UP" key four times. "001234" is showing and the sixth digit is flashing.
Press "ENTER" key. "001234" flashes on the lower display and "ArE YOU SUrE" is showing on the upper display.
For "yes", press "ENTER" key. "001234" stops flashing.
For "no", press "SELECT" key. "000000" is showing and the first digit is flashing. Repeat this procedure to program the hourmeter again.Note: In order to exit this procedure without saving any changes, press the exit key twice when the display shows "ArE YOU SUrE". The GSC returns to the normal display. The original value for the hourmeter is kept in the memory of the GSC. Note: Lower hours cannot be entered into the GSC if the GSC has a value that is stored. the upper display briefly shows "Error". The display then shows the original hours that are stored in the GSC and the first digit is flashing.
Press "EXIT" key. "OP 1" is showing on lower display.
Press "EXIT" key. The display returns to the normal mode. The programmed value for the hourmeter should show on the lower display as the engine data scrolls.


Parts pin Mercruiser:

821997
PIN, Hinge, For Use Without Trim Senders
821997 PIN, Hinge, For Use Without Trim Senders
5120136JS, 5120150AR, 5220200AS, 5231100LP, 5C30150FS, 5E31200N1, 6020006JS, 6211001N1, 6311002NZ, 6315002NZ, 6416003N2, 6511102N1, 6811001N1
805256
PIN-ANCHOR (FRONT)
805256 PIN-ANCHOR (FRONT)
5C30150FS, 6020006JS
805095
PIN-ANCHOR (REAR)
805095 PIN-ANCHOR (REAR)
5C30150FS, 6020006JS
15878
 
15878 PIN, Clevis
4S42028N1, 4S42028TS, 4S42028TT, 4S42028UT, 4S42028UU, 4S420P8UE, 5000147JS, 5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810T
16419
 
16419 PIN, Clevis
4S42028N1, 4S42028TS, 4S42028TT, 4S42028UT, 4S42028UU, 4S420P8UE, 5000147JS, 5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810T
78310
 
78310 PIN TOOL, Hinge
5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200T
840728
PIN, Mounting
840728 PIN, Mounting
5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200TP, 5E36200TS, 5E36210TP, 5E36210TS, 5E36800TP, 5E36800TS, 5E36810TP, 5E36810T
840832
PIN
840832 PIN
5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200TP, 5E36200TS, 5E36210TP, 5E36210TS, 5E36800TP, 5E36800TS, 5E36810TP, 5E36810T
Back to top