863839 COVER Mercruiser
40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 424106LRS, 424106LTT, 424106LUS, 424106PUU, 444106LPS, 444236HRS, 4M4102LPS, 4M4102LRS, 4M4102LTS
COVER
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
Mercruiser entire parts catalog list:
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
- WATER DISTRIBUTION HOUSING » 863839
Information:
Illustration 1 g01107274
Illustration 2 g01107279When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Minimum speed with no load ... 3300 rpmMaximum current with no load ... 80 ampVoltage ... 23.5 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 1.5 0.5 N m (13 4 lb in) (3) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 17.5 2.5 N m (155 22 lb in)Current draw at 24 V and 25 °C (77 °F)Pull-in windings ... 103 AmpHold-in windings ... 19 Amp maximum 6V-5537 Electric Starting Motor Gp and 6V-5207 Electric Starting Motor Gp
Illustration 3 g01107221
Illustration 4 g01107223When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F)Speed ... 7643 1683 rpmCurrent draw ... 67.5 7.5 ampVoltage ... 23 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 8 3 N m (70 27 lb in)Clearance between the pinion and the housing ... 9.1 mm (0.36 inch) 6V-5023 Electric Starting Motor Gp
Illustration 5 g01107286
Illustration 6 g01107308When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 5500 rpm minimumCurrent draw ... 140 amp maximumVoltage ... 24 V (1) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (2) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 30.5 3.5 N m (270 30 lb in) 9X-0332 Solenoid KitCurrent consumption at 25 °C (77 °F) Pull-in windings at 24 V ... 51 ampHold-in windings at 24 V ... 7 amp
Parts cover Mercruiser:
828054
828054 COVER, Fuse
40200002D, 40200002G, 40500006T, 40500010T, 40500010U, 40500120U, 41510P1UE, 4S42028N1, 4S42028TS, 4S42028TT, 4S42028UT, 4S42028UU, 4S420P8UE, 5231100TP, 5232100TP, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810T
814875
814875 COVER, Heat Exchanger End
40430002S, 4211015L1, 4211025RS, 4211025TS, 4211025TT, 4211025US, 4211025UU, 4231017L1, 424106LRS, 424106LTT, 424106LUS, 424106PUU, 4332087N1, 4441027LE, 444106AM1, 444106LPS, 444236HRS, 4542067LS, 4652027LE, 4652027M1, 4652227MW, 4M11025LS, 4M31027L
883562
883562 COVER, Fuse
40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 424106LRS, 424106LTT, 444106LPS, 444236HRS, 4M4102LPS, 4M4102LRS, 4M4102LTS, 4S42028N1, 4S42028TS, 4S42028TT
863865
863865 COVER
40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 424106LRS, 424106LTT, 424106LUS, 424106PUU, 444106LPS, 444236HRS, 4M4102LPS, 4M4102LRS, 4M4102LTS
862776A01
862776A01 COVER KIT, Impeller Housing
40500006T, 40500010T, 40500010U, 40500120U, 4211025TT, 4211025US, 4211025UU, 424106LTT, 424106LUS, 424106PUU
879194362
879288T67
864708
864708 COVER, End, Heat Exchanger
40500006T, 40500010T, 40500010U, 40500120U, 444236HRS, 4M4102LRS, 4M4102LTS