55116 Mercruiser HOSE, PRESSURE - POWER STEERING (72")


55116 HOSE, PRESSURE - POWER STEERING (72") Mercruiser 00014332, 01206002, 01207333, 01326013, 01406002, 01407333, 02287333, 02607333, 03302336, 03307332, 08986342, 2140208, 2165208, 2250507, 228801, 260801, 44031854 HOSE
55116 HOSE, PRESSURE - POWER STEERING (72") Mercruiser
Rating:
98

Buy HOSE, PRESSURE - POWER STEERING (72") 55116 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

Mercruiser entire parts catalog list:

00014332 1982
01206002 1982,1983
01207333 1983
01326013 1983
01406002 1982
01407333 1983
02287333 1983
02607333 1983
03302336 1986
03307332 1982
08986342 1982,1983
2140208 1978,1979,1980,1981,1982
2165208 1978
2250507 1977
228801 1981,1982
260801 1981,1982,1987
44031854 1984

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
101-13
Crankcase Air Pressure Sensor : Out of Calibration 101-13
Crankcase Air Pressure Sensor : Out of Calibration During key on, the signal voltage from the crankcase air pressure sensor indicated a crankcase air pressure greater than +/- 1.5 kPa (0.2 psi).
There is not a reference sensor for this sensor.
3563-13
Engine Intake Manifold #1 Absolute Pressure : Out of Calibration 1785-13
Intake Manifold Pressure Sensor : Out of Calibration During key on, the signal voltage from the intake manifold pressure sensor indicated an intake manifold pressure greater than +/- 18 kPa (3 psi).
Reference sensor: Atmospheric Pressure Sensor
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
Note: The engine coolant temperature must be greater than 0° C (32° F) before beginning this procedure.
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check for Debris
A. Turn the keyswitch to the OFF position.
B. Check the sensor for debris.
C. If applicable, check the reference sensor for debris.
D. Check the sensor measurement port for blockage by debris.
E. If debris is found, clear the debris from the measurement port and replace the sensor.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Debris
Result: The sensor measurement port is not blocked by debris.
Proceed to Test Step 3.
Result: A -13 code is not active.
Return to service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Inspect the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Inspect the sensor connector for moisture and corrosion.
Moisture
Result: The sensor connector does not have moisture or corrosion.
Proceed to Test Step 5.
Result: The sensor connector has moisture and/or corrosion.
Proceed to Test Step 4.
4. Remove any moisture and/or corrosion
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor connector.
C. Remove any moisture and/or corrosion from the outside of the connector. Check for moisture and corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 5.
5. Check for Moisture and/or Corrosion in the Circuit
A. Turn the keyswitch to the OFF position.
B. Check all the connectors in the circuit for moisture and/or corrosion.
C. Check for corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts hose Mercruiser:

47640
 
47640 HOSE, WATER DISTRIBUTION BLOCK TO WATER PUMP
01206002, 01207333, 01326013, 01406002, 01407333, 2165203, 2165208
47642
 
47642 HOSE, HSG. TO PICKUP TUBE (49")
01207333, 01402414, 01406002, 01407333, 04706002, 04707333, 04708004, 04856332, 04881333, 2250507, 2888203
73796
 
73796 HOSE, THERMOSTAT COVER TO EXH. ELBOWS (REAR)
02287333, 02607333, 08986342, 228801, 260801
55117
 
55117 HOSE, RETURN - POWER STEERING (72") - NOT AS SHOWN
01206002, 01207333, 01326013, 01406002, 01407333
53461 70
 
53461 70 HOSE, (48.00 Inches Bulk), WATER PUMP TO OIL COOLER (7")
03307332, 03308333, 04544347, 37011856, 5E31200N1, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910TP, 5E31910TS, 5E32200TP, 5E32900TS, 5E36200TP, 5E36200TS, 5E36210TP, 5E36210TS, 5
98494
 
98494 HOSE ASSEMBLY, PRESSURE FITTINGS ON BOTH ENDS)
03307332, 03308333, 04544347, 37011856
98629 1
 
98629 1 HOSE, PRESSURE (FITTINGS/BOTH ENDS) (JACKSHAFT MODELS)
00014332, 02287333, 02602347, 02607333, 02608427, 08987343
96764
 
96764 HOSE, COOLER TO HOUSING - 5/8" I.D
01207333, 01402414, 01407333
Back to top