805505A 4 HOSE, Oil Drain Mercruiser
40430002S, 4111021L1, 411102KN2, 4211015L1, 4211025RS, 4231017L1, 424106LRS, 444106LPS, 444236HRS, 4542067LS, 4652027M1, 4652227MW, 4M11025LS, 4M11025RS, 4M4102LPS, 4M4102LRS, 4R42027N1, 4S42028N1
HOSE
Price: query
Rating:
Compatible models:
Mercruiser entire parts catalog list:
- OIL PAN, OIL PUMP AND REAR OIL SEAL » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN, OIL PUMP AND REAR OIL SEAL » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN, OIL PUMP AND REAR OIL SEAL » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND OIL PUMP » 805505A 4
- OIL PAN AND DRAIN SYSTEM » 805505A 4
Information:
Personal injury can result from contact with refrigerant.This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Open the left engine guard.
Illustration 1 g00818937
Remove oil filters (1).
Illustration 2 g00818938
Cut cable ties (4).
Remove bolts (3).
Remove oil pan plate (2).
Illustration 3 g00818949
Loosen nut (6), nut (6A), and bolt (7).
Move V-Belt (5) aside.
Illustration 4 g00818951
Remove bolt (8), the nut, and washers.
Remove bolt (9), washers, and the spacer.
Remove rod (10).
Disconnect connector (11).
Illustration 5 g00818959
Disconnect hose assemblies (12) and (13).
Illustration 6 g00818960
Remove nut (15), bolt (16), and washers.
Remove refrigerant compressor (14). Installation Procedure
Personal injury can result from contact with refrigerant.This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
Illustration 7
Parts hose Mercruiser:
806993
806174 63
806174 63 HOSE, (33.00 Inches Bulk) (.375 Inch I.D.)
4111021L1, 430L000JS, 4454118JT, 474L118JT, 4M31027LS
806173 30
861304A01
863611
863611 HOSE, Sea Pump To Power Steering Cooler
40430002S, 40500006T, 40500010T, 40500010U, 424106LRS, 424106LTT, 424106LUS, 424106PUU, 444106LPS, 444236HRS, 4M4102LPS, 4M4102LRS, 4M4102LTS
863465
863465 HOSE, Drain Accumulator to Tee Fitting
40430002S, 40500006T, 40500010T, 40500010U, 424106LRS, 424106LTT, 424106LUS, 424106PUU, 444106LPS, 444236HRS, 4M4102LPS, 4M4102LRS, 4M4102LTS
860327
864886
864886 HOSE, Heat Exchanger to Circulating Pump
40500006T, 40500010T, 40500010U, 40500120U, 4211025RS, 4211025TS, 4211025TT, 4211025US, 4211025UU, 424106LRS, 424106LTT, 424106LUS, 424106PUU