Table 1
Diagnostic Trouble Codes
CDL Code J1939 Code Code Description Comments
100-3 100-3 Engine Oil Pressure Sensor : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
100-4 100-4 Engine Oil Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
101-3 101-3 Crankcase Air Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
101-4 101-4 Crankcase Air Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
274-3 108-3 Atmospheric Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
274-4 108-4 Atmospheric Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
289-3 5578-3 Fuel Pressure Sensor - Before Fuel Filter : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
289-4 5578-4 Fuel Pressure Sensor - Before Fuel Filter : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
460-3 5580-3 Fuel Pressure Sensor - After Fuel Filter : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
460-4 5580-4 Fuel Pressure Sensor - After Fuel Filter : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1785-3 3563-3 Intake Manifold Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1785-4 3563-4 Intake Manifold Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1797-3 157-3 Fuel Rail Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1797-4 157-4 Fuel Rail Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1835-3 1387-3 Auxiliary Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
1835-4 1387-4 Auxiliary Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2452-3 3242-3 DPF #1 Intake Temperature Sensor : Voltage Above Normal The code is logged.
The ECM detects voltage that is not in the acceptable range.
2452-4 3242-4 DPF #1 Intake Temperature Sensor : Voltage Below Normal The code is logged.
The ECM detects voltage that is not in the acceptable range.
2458-2 3251-2 DPF #1 Differential Pressure Sensor : Erratic, Intermittent, or Incorrect The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2458-3 3251-3 DPF #1 Differential Pressure Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2458-4 3251-4 DPF #1 Differential Pressure Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2460-3 3480-3 ARD Fuel Pressure #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2460-4 3480-4 ARD Fuel Pressure #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2497-3 4077-3 ARD Fuel Pressure #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
The value of the parameter is set to a default pressure.
2497-4 4077-4 ARD Fu