8M2001800 Mercruiser PAD


8M2001800 PAD Mercruiser 41000001S, 41000008E PAD
8M2001800 PAD Mercruiser
Rating:
73

Buy PAD 8M2001800 Mercruiser genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$29.76
 

11-05-2019
13 Hundredths Pounds
MERCURY: MERCURY
New Mercury Mercruiser Quicksilver OEM Part # 8M2001800 PAD-EXHAUST MOUNT
Number on catalog scheme: 6
 

Compatible models:

41000001S   41000008E   Mercruiser

Mercruiser entire parts catalog list:

Information:


Illustration 1 g00291249
Typical example
Note: All water temperature regulators do not have air vent valves (1). 119-3075 Water Temperature Regulator 126-5869 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 83 °C (172 ° to 181 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.75 mm (0.345 inch) 115-4223 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 102-8392 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 107-7568 Water Temperature Regulator 7E-5254 Water Temperature Regulator 119-3075 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 93 °C (199 °F)Begin to open temperature of the water temperature regulator. ... 79 ° to 82 °C (174 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 108-7045 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 93.9 °C (201.0 °F)Begin to open temperature of the water temperature regulator. ... 81.1 ° to 83.9 °C (178 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 7C-2190 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch) 7E-1420 Water Temperature Regulator 9Y-3088 Water Temperature Regulator 9Y-3365 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 94.4 °C (202 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.1 mm (0.32 inch) 1W-8801 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 1W-8802 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.72 0.25 mm (1.170 0.010 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch)
Illustration 2 g00589065
Typical example
4W-4011 Water Temperature Regulator 120-9453 Water Temperature Regulator 6I-4954 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 89 °C (192 °F)Begin to open temperature of the water temperature regulator. ... 75 ° to 78 °C (167 ° 172 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch) 4W-4794 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 92 °C (198 °F)Begin to open temperature of the water temperature regulator. ... 81 ° to 84 °C (178 ° to 183 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch)


Parts pad Mercruiser:

8M2001799
PAD
8M2001799 PAD
41000001S, 41000008E