853041 Mercruiser PLUG, CUP


853041 PLUG, CUP Mercruiser 473B116KD PLUG
853041 PLUG, CUP Mercruiser
Rating:
48

Buy PLUG, CUP 853041 Mercruiser genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$21.89
 

23-11-2023

-: -
The Hillman Group 853041 .148 x 1-1/2-Inch Angled Hook, Zinc Plated (2)
$4.91
 

23-11-2023

-: -
The Hillman Group 853041 .148 x 1-1/2-Inch Angled Hook, Zinc Plated
Great for organizing your garage or workbench || For 1/8" and 1/4" pegboard || Zinc Plated || Steel Material provides strength and durability
$140.17
 

01-10-2022
2.5[1.12] Pounds
-: -
APDTY 853041 Window Lift Motor (Motor Only)
Meets Or Exceeds OEM Specs || Factory OEM Fit Form And Function
Number on catalog scheme: 16
 

Compatible models:

473B116KD   Mercruiser

Mercruiser entire parts catalog list:

473B116KD 1997,1998

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
611-5
System Diagnostic Code #1 : Current Below Normal N/A This code indicates that there is a problem with the engine starter motor solenoid and/or the electrical circuit on the ECM.
611-6
System Diagnostic Code #1 : Current Above Normal N/A This code indicates that there is a problem with the engine starter motor solenoid and/or the electrical circuit on the ECM.
677-5
Engine Starter Motor Relay : Current Below Normal 444-5
Starter Motor Relay : Current Below Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
677-6
Engine Starter Motor Relay : Current Above Normal 444-6
Starter Motor Relay : Current Above Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
4210-5
Engine Pre-lube Drive : Current Below Normal 338-5
Engine Pre-Lube Pump Relay : Current Below Normal This code indicates that there is a problem with the prelubrication solenoid and/or the electrical circuit on the ECM.
4210-6
Engine Pre-lube Drive : Current Above Normal 338-6
Engine Pre-Lube Pump Relay : Current Above Normal This code indicates that there is a problem with the prelubrication solenoid and/or the electrical circuit on the ECM. Electrical Checkouts on the Cat® Electronic Technician (ET)
Table 2
Component Electrical Checkout
Engine Starter Solenoid Attempt to start the engine. Once the ECM attempts to energize the solenoid, the code will become active. Refer to the application-specific schematic for the "Engine Starter Motor Solenoid" wiring circuit.
Engine Starter Motor Relay Attempt to start the engine. Once the ECM attempts to energize the solenoid, the code will become active. Refer to the application-specific schematic for the "Engine Starter Motor Relay" wiring circuit.
Prelubrication System Relay Prelubrication Relay Override
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Disconnect the solenoid from the harness.
C. Connect a jumper wire between the terminals of the harness connector for the affected coil. The coil is replaced with a short circuit.
Create a Short
Result: A -5 code became active during the electrical checkout. The ECM did not detect the jumper wire. There is an open circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -6 code is activated during the electrical checkout. The ECM detected the jumper wire. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Disconnect the solenoid from the harness.
Create an Open
Result: A -6 code became active during the electrical checkout. The ECM did not detect the open circuit. There is a short circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -5 code is activated during the electrical checkout. The ECM detected the open circuit. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts plug Mercruiser:

73379
 
73379 PLUG, (.250-18), PIPE - EXHAUST MANIFOLD
00014332, 02287333, 02297343, 02607333, 02608427, 03302336, 03307332, 03308333, 04544347, 06661346, 07711346, 08987343, 32001876, 37011856, 40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 4052110CR, 41000001S, 41000008E, 4211015L1, 4211025RS,
808125
 
808125 PLUG (1/8-27)
473B116KD, 473B1F0GS
853033
853099
39072 1
PLUG, Pipe (.125-27) Brass
39072 1 PLUG, Pipe (.125-27) Brass
40430002S, 40500006T, 40500010T, 40500010U, 444236HRS, 473B116KD, 4M11025RS, 4M11025TS, 4M11025TT, 4M11025US, 4M4102LRS, 4M4102LTS, 5E31200TP, 5E31200TS, 5E31210TP, 5E31210TS, 5E31800TP, 5E31800TS, 5E31810TP, 5E31810TS, 5E31900TP, 5E31900TS, 5E31910T
802791
 
802791 PLUG
473B116KD
853411
Back to top