Breathing ether vapors or repeated contact of ether with skin can cause personal injury. Personal injury may occur from failure to adhere to the following procedures.Use ether only in well ventilated areas.Do not smoke while changing ether cylinders.Use ether with care to avoid fires.Do not store replacement ether cylinders in living areas or in the operator's compartment.Do not store ether cylinders in direct sunlight or at temperatures above 49 °C (120 °F).Discard cylinders in a safe place. Do not puncture or burn cylinders.Keep ether cylinders out of the reach of unauthorized personnel.To avoid possible injury, be sure the brakes are applied and all controls are in Hold or Neutral when starting the engine.
Test Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J3/P3 machine connector, and all other connectors in the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Inspect the following components for damage, corrosion, and incorrect attachment:
Battery posts
Alternator
Breaker
Engine ground
Chassis groundExpected Result:All connectors, pins, and sockets should be completely inserted and coupled. The harness and wiring should be free of corrosion, abrasion, and pinch points. All connections and grounds should be tight and free of corrosion.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem. Stop.Test Step 2. Check the Starting Aid Switch Status on the Electronic Service Tool
Remove the ether canister from the ether solenoid.
Connect the electronic service tool to the service tool connector.
Turn the keyswitch to the ON position.
Press the starting aid switch to "MANUAL". Observe the "Starting Aid Switch Status" on the electronic service tool.Expected Result:When the starting aid switch is pressed, the electronic service tool should display the status of the starting aid switch as ON.When the starting aid switch is not pressed, the electronic service tool should display the status of the starting aid switch as OFF.Results:
OK - The starting aid switch is operating correctly. Proceed to Test Step 6.
Not OK - The ECM is not properly reading the signal from the starting aid switch. Proceed to Test Step 3.Test Step 3. Check the Resistance of the Relay
Illustration 2 g00743796
Connector for the ether relay
Turn the keyswitch to the OFF/RESET position.
Disconnect the wires at terminal 85 (Ether ON) and terminal 86 (Solenoid Return) at the ether relay.
Measure the resistance across terminal 85 (Ether ON) and terminal 86 (Solenoid Return).
Reconnect the wires to the ether relay.Expected Result:The resistance should be between 250 Ohms and 500 Ohms.Results:
OK - Proceed to Test Step 4.
Not OK - The relay is faulty.Repair: Replace the relay.Verify that the repair eliminates the problem. Stop.Test Step 4. Short the Switch Wires
Remove wire F720-GN (Starting Aid Switch) and wire 998-BR (Digital Return) from the starting aid switch.
Short wire F720-GN (Starting Aid Switch) to wire 998-BR (Digital Return).Expected Result:When the wires are shorted, the electronic service tool should display the status of the starting aid switch as ON.When the wires are not shorted, the electronic service tool should display the status of the starting aid switch as OFF.Results:
OK - The starting aid switch is not operating correctly.Repair: Replace the starting aid switch.Verify that the repair eliminates the problem. Stop.
Not OK - The starting aid switch is operating correctly. Proceed to Test Step 5.Test Step 5. Short the Switch Inputs at the ECM
Illustration 3 g00935194
J1/P1 breakout
Turn the keyswitch to the OFF position and install a 7X-1715 Adapter Cable (40 Pin Breakout T) at ECM connector J1/P1.
Turn the keyswitch to the ON position.
Use a suitable piece of wire to short P1:25 (Starting Aid Switch) and P1:29 (Digital Return) at the breakout.
Observe the results on the "Status" screen on the electronic service tool.Expected Result:When the wires are shorted, the electronic service tool should display the status of the starting aid switch as ON.When the wires are not shorted, the electronic service tool should display the status of the starting aid switch as OFF.Results:
OK - There is a problem in the wiring between the switch and the ECM.Repair: Repair the circuit.Verify that the repair eliminates the problem. Stop.
Not OK - The ECM is not reading the switch input properly.Repair: Verify your results. Replace the ECM. Refer to Troubleshooting, "Replacing the ECM" before replacing the ECM.Verify that the repair eliminates the problem. Stop.Test Step 6. Check the Resistance of the Ether Solenoid


Parts screw Mercruiser:

40001209
 
40001209 SCREW (60MM)
40280002D, 40420001D, 40420002D, 428B116KD, 442B110GD, 442B115KD, 4A72040ND, 4C72040TD, 4C8204DLD, 4CJ2040ND
896332203
 
896332203 SCREW
40200002D, 40200002G, 40280001D, 40280002D, 40420001D, 40420002D, 4C72040TD, 4C8204DLD
879172086
 
879172086 SCREW
40200002D, 40200002G, 40280002D, 40420002D
898101561
 
898101561 SCREW
40280002D, 40420002D
879194139
 
879194139 SCREW
40280002D, 40420002D
879194126
 
879194126 SCREW
40280002D, 40420002D
879150079
 
879150079 SCREW
40280002D, 40420002D
879271
 
879271 SCREW
40280002D, 40420002D
Back to top