93919A 1 Mercruiser SHIELD ASSEMBLY, UPPER


93919A 1 SHIELD ASSEMBLY, UPPER Mercruiser 00014332, 01207333, 01402414, 01407333, 02287333, 02602347, 02607333, 02608427, 08986342, 08987343, 228801, 257B021JS, 260801, 40280002D, 40420001D, 40420002D, 40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 4211025RS, 4211025TS, 4211025TT, 42 SHIELD
93919A 1 SHIELD ASSEMBLY, UPPER Mercruiser
Rating:
78

Buy SHIELD ASSEMBLY, UPPER 93919A 1 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

Mercruiser entire parts catalog list:

00014332 1982
01207333 1983
01402414 1984,1985,1986,1987,1988,1989
01407333 1983
02287333 1983
02602347 1987,1988,1989,1990,1991,1992,1993,1994,1995
02607333 1983
02608427 1987
08986342 1982,1983
08987343 1983,1984,1985,1986,1987
228801 1981,1982
257B021JS 1996,1997
260801 1981,1982,1987
40280002D 1998
40420001D 1998
40420002D 1998
40430002S 1998
40500006T 1998
40500010T 1998
40500010U 1998
40500120U 1998
4211025RS 1998
4211025TS 1998
4211025TT 1998
4211025US 1998
4211025UU 1998
424106LRS 1998
424106LTT 1998
424106LUS 1998
424106PUU 1998
444106LPS 1998
444236HRS 1998
457B100KS 1997
4A72040ND 1998
4C72040TD 1998
4C8204DLD 1998
4M11025RS 1998
4M11025TS 1998
4M11025TT 1998
4M11025US 1998
4M4102LPS 1998
4M4102LRS 1998
4M4102LTS 1998
4V71222ND 1998
4V71222PD 1998
4V71222TD 1998
5232100TP 1998
6311002NZ 1998
6315002NZ 1998
6811001N1 1998

Information:

During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Check that the fuses are not blown.
B. Inspect the terminals on the start relay. Refer to Troubleshooting, "Electrical Connector - Inspect" for details.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the start relay.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness for abrasion and pinch points from the start relay back to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all of the seals are properly in place and ensure that the connectors are correctly coupled.
Replace any blown fuses.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points. The fuses are not blown.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position.
Note: Do not start the engine.
C. Use the electronic service tool to check for active diagnostic codes.
Diagnostic codes
Result: Diagnostic code 677-5 or 444-5 is active or recently logged.
Proceed to Test Step 3.
Result: Diagnostic code 677-6 or 444-6 is active or recently logged.
Proceed to Test Step 6.
3. Check the Battery Supply Voltage at the Relay Connector
A. Turn the keyswitch to the OFF position.
B. Turn the keyswitch to the ON position. Do not start the engine.
C. Measure the voltage between the battery input terminal on the relay and a suitable ground.
At least 11 VDC for a 12 VDC system. At least 22 VDC for a 24 VDC system.
Result: The voltage is not within the expected range.
Repair: Repair or replace the battery supply wiring to the start relay.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The voltage is within the expected range.
Proceed to Test Step 4.
4. Create a Short Circuit at the Relay Connector
A. Turn the keyswitch to the OFF position.
B. Remove the start relay.
C. Fabricate a jumper wire. Install the jumper wire between terminal 1 and terminal 2 on the harness connector for the start relay.
D. Turn the keyswitch to the ON position.
E. Use the electronic service tool to check for active diagnostic codes. Wait at least 30 seconds for activation of the diagnostic codes.
F. Turn the keyswitch to the OFF position and remove the jumper wire.
Diagnostic code
Result: A 677-6 or 444-6 diagnostic code is active with the jumper installed.
Repair: Install a replacement start relay.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The 677-5 or 444-5 diagnostic code is still active.
Proceed to Test Step 5.
5. Check the Relay Control Wiring for an Open Circuit
A. Verify that the keyswitch is in the OFF position.
B. Disconnect the P1 connector from the ECM.
C. Inspect the P1 connector. Refer to Troubleshooting, "Electrical Connector - Inspect" for details.
D. Measure the resistance between Terminal 1 on the harness connector for the start relay and the "Start Relay Control" terminal on the P1 connector.
E. Measure the resistance between Terminal 2 on the harness connector for the start relay and ground.
Less than five Ohms
Result: At least one of the resistance measurements is greater than five Ohms - the fault is in the wiring for the start relay control circuit.
Repair: Repair the faulty wiring or replace the faulty wiring.
Result: Both resistance measurements are less than five Ohms.
Contact the Dealer Solutions Network (DSN).
6. Create an Open Circuit at the Relay
A. Turn the keyswitch to the OFF position.
B. Disconnect the start relay.
C. Use the electronic service tool to check for active diagnostic codes. Wait at least 30 seconds for activation of the diagnostic codes.
Diagnostic codes
Result: A 677-5 or 444-5 diagnostic code is active with the relay disconnected.
Repair: Install a replacement start relay.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The 677-6 or 444-6 diagnostic code is still active with the relay disconnected.
Proceed to Test Step 7.
7. Check the Wiring Between the Relay and the ECM for a Short Circuit
A. Disconnect the P1 connector.
B. Inspect the P1 connector. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Measure the resistance between the "Start Relay Control" terminal and all other terminals on the P1 connector.
Greater than 1.0 k Ohm
Result: At least one of the resistance measurements is less than 1.0 k Ohm. There is a short in the wiring between the relay and the ECM.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All resistance measurements are greater than 1.0 k Ohm.
Contact the Dealer Solutions Network (DSN).


Parts shield Mercruiser:

34518
 
34518 SHIELD, VALUE SPRING CAP
00014332, 01206002, 01207333, 01326013, 01402414, 01406002, 01407333, 01751347, 01851333, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 07711346, 08986342, 08987343, 2165203, 2165208, 228801, 257B021JS, 260801, 30001854, 32001876, 40430
93918A 1
 
93918A 1 SHIELD ASSEMBLY, LOWER
00014332, 01207333, 01402414, 01407333, 02287333, 02602347, 02607333, 02608427, 08986342, 08987343, 228801, 257B021JS, 260801, 40280002D, 40420001D, 40420002D, 40430002S, 40500006T, 40500010T, 40500010U, 40500120U, 4211025RS, 4211025TS, 4211025TT, 42
814470
 
814470 SHIELD
01751347, 02602347, 02608427, 4052110CR, 44541101S, 4454110AS, 45021102S, 474H110AR
850490
SHIELD
850490 SHIELD
4231017L1, 4262C01JT
889340
 
889340 SHIELD, Heat ( Turbo )
4V71222ND, 4V71222PD, 4V71222TD
34518001
 
34518001 SHIELD
4211025US, 4211025UU, 424106LUS, 424106PUU
862873T
SHIELD, Upper
862873T SHIELD, Upper
4231017L1, 5232100TP, 6311002NZ, 6315002NZ, 6811001N1
Back to top