J1939 Code and Description Comments
100-3
Engine Oil Pressure : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
100-4
Engine Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
107-3
Engine Air Filter 1 Differential Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
107-4
Engine Air Filter 1 Differential Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
108-3
Barometric Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
108-4
Barometric Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
109-3
Engine Coolant Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
109-4
Engine Coolant Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
1208-3
Engine Pre-filter Oil Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
1208-4
Engine Pre-filter Oil Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
4817-3
Engine Intake Manifold #1 Absolute Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
4817-4
Engine Intake Manifold #1 Absolute Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5631-3
Engine Throttle Valve Differential Pressure : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5631-4
Engine Throttle Valve Differential Pressure : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5708-3
Engine Coolant Pressure #2 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged.
5708-4
Engine Coolant Pressure #2 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The value of the parameter is set to a default value.
The code is logged. The ECM continuously creates a pull-up voltage on the signal wire for each sensor. The ECM uses this pull-up voltage to detect a problem in the signal circuit. When the ECM detects voltage that is above a threshold on the signal wire, the ECM activates a high voltage -3 diagnostic . When the ECM detects voltage that is below a threshold on the signal wire, the ECM activates a low voltage -4 diagnostic .Note: There may be a delay of 30 seconds in order for Cat® Electronic Technician (ET) to display an active diagnostic . When you check for a diagnostic , be sure to wait at least 30 seconds.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -3 code is active.
Proceed to Test Step 2.
Result: A -4 code is active.
Proceed to Test Step 3.
2. Create a Short at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor with the active -3 code.
C. Install the jumper wire between the following terminals at the sensor connector:
- Terminal 3 (signal) and Terminal 2 (sensor return)
D. Connect Cat ET.
E. Use Cat ET to monitor the following:
- -4 code
F. Turn the keyswitch to the OFF position.
Create a Short
Result: A -4 code did not become active.
Proceed to Test Step 4.
Result: A -4 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
3. Create an Open at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor with the active -4 code.
C. Connect Cat ET.
D. Use Cat ET to monitor the following:
- -3 code
E. Turn the keyswitch to the OFF position.
Create an Open
Result: A -3 code did not become active.
Proceed to Test Step 4.
Result: A -3 code became active.
Repair: The wiring harness is OK. Replace the sensor.
Verify that the repair eliminated the problem.
4. Check the 5 VDC Supply Voltage at the Sensor Connector
A. Turn the keyswitch to the ON position.
B. Measure the voltage at the sensor connector between the following pins:
- Pin 1 and Pin 2
C. Reconnect the sensor.
5.0 0.2 VDC
Result: The supply voltage is 5.0 0.2 VDC.
Proceed to Test Step 5.
Result: The supply voltage is not 5.0 0.2 VDC.
Repair:Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 5.
5. Perform the Wiggle Test
Carefully following this procedure is the best way to identify the root cause of an intermittent problem.
A. Connect Cat ET.
B. Use CAT ET to perform the following test:
- "Wiggle Test"
C. Slowly wiggle the wiring and the connectors between the P2 connector and the sensor. Pay particular attention to the wiring near each connector. Be sure to wiggle all the wiring.
As you wiggle the wiring look for these problems:
- Loose connectors or damaged connectors
- Moisture on the connectors


Parts sleeve Mercruiser:

57908 2
 
57908 2 SLEEVE, WIRING HARNESS
01206002, 01207333, 01326013, 01851333, 02287333, 02607333, 2165203, 2165208, 228801, 260801
45600
 
45600 SLEEVE, SWITCH ACTUATING STUD
00014332, 01207333, 01402414, 01407333, 01701335, 01851333, 01854335, 02287333, 02607333, 02608427, 04544347, 04707333, 04708004, 04881333, 06661346, 07711346, 08986342, 08987343, 2140208, 2165208, 2250507, 228801, 260801, 2888203, 30001854, 32001876
60652
 
60652 SLEEVE, ADJUSTING - CABLE GUIDE TUBE
00014332, 01206002, 01207333, 01321017, 01326013, 01406002, 01407333, 02287333, 02607333, 03301310, 03302336, 03307332, 04706002, 04707333, 08986342, 2140208, 2165208, 2250507, 228801, 260801, 30001854, 37011856, 44031854
7020
 
7020 SLEEVE, INSULATOR
00014332, 01206002, 01207333, 01326013, 01402414, 01406002, 01407333, 01751347, 01851333, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 03302336, 03307332, 03308333, 04544347, 06661346, 07711346, 08986342, 08987343, 228801, 260801, 3000
7018
 
7018 SLEEVE, INSULATOR
00014332, 01206002, 01207333, 01326013, 01402414, 01406002, 01407333, 01751347, 01851333, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 03302336, 03307332, 03308333, 04544347, 06661346, 07711346, 08986342, 08987343, 228801, 260801, 3000
47511
 
47511 SLEEVE, THERMOSTAT HOUSING
00014332, 01751347, 01851333, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 03302336, 03307332, 03308333, 04544347, 04706002, 04707333, 06661346, 07711346, 08986342, 08987343, 228801, 260801, 30001854, 32001876, 37011856, 44031854, 4454
60096
 
60096 SLEEVE, TERMINAL END COVER
01206002, 01207333, 01326013, 01406002, 01407333
57908 11
SLEEVE, ALTERNATOR LEADS
57908 11 SLEEVE, ALTERNATOR LEADS
00014332, 01207333, 01402414, 01407333, 01751347, 01854335, 02287333, 02297343, 02602347, 02607333, 02608427, 03307332, 03308333, 04544347, 06661346, 07711346, 08987343, 257B021JS, 30001854, 32001876, 37011856, 430B00001, 4350104JS, 4350111HS, 435011
Back to top