56292A 4 Mercruiser THRUST HUB (FOR USE W/M/C I PROPELLERS)


56292A 4 THRUST HUB (FOR USE W/M/C I PROPELLERS) Mercruiser 00019003, 01321017, 01326013, 5000165CE THRUST
56292A 4 THRUST HUB (FOR USE W/M/C I PROPELLERS) Mercruiser
Rating:
58

Buy THRUST HUB (FOR USE W/M/C I PROPELLERS) 56292A 4 Mercruiser genuine, new aftermarket parts with delivery
Number on catalog scheme: 80
 

Compatible models:

Mercruiser entire parts catalog list:

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
5966-5
Aftertreatment #1 DEF Control Module Power Supply : Current Below Normal 3965-5
Aftertreatment #1 DEF Controller #1 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5966-6
Aftertreatment #1 DEF Control Module Power Supply : Current Above Normal 3965-6
Aftertreatment #1 DEF Controller #1 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
5968-5
Aftertreatment #2 DEF Control Module Power Supply : Current Below Normal 4801-5
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5968-6
Aftertreatment #2 DEF Control Module Power Supply : Current Above Normal 4801-6
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-5
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Below Normal 3966-5
Aftertreatment #1 DEF Controller #1 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-6
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Above Normal 3966-6
Aftertreatment #1 DEF Controller #1 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
6310-5
Aftertreatment #2 DEF Control Module #1 Power Supply #2 : Current Below Normal 4802-5
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6310-6
Aftertreatment #2 DEF Control Module #1 Power Supply #2 : Current Above Normal 4802-6
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
7522-5
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Below Normal 4799-5
Aftertreatment #1 DEF Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7522-6
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Above Normal 4799-6
Aftertreatment #1 DEF Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-5
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Below Normal 4800-5
Aftertreatment #1 DEF Controller #2 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-6
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Above Normal 4800-6
Aftertreatment #1 DEF Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-5
Aftertreatment #2 DEF Control Module #2 Power Supply #1 : Current Below Normal 4803-5
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-6
Aftertreatment #2 DEF Control Module #2 Power Supply #1 : Current Above Normal 4803-6
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-5
Aftertreatment #2 DEF Control Module #2 Power Supply #2 : Current Below Normal 4804-5
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-6
Aftertreatment #2 DEF Control Module #2 Power Supply #2 : Current Above Normal 4804-6
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
Illustration 1 g06522429
(1) Aftertreatment #1 DCU #1 (blue)
(2) Aftertreatment #1 .DCU #2 (green)
(3) Aftertreatment #2 .DCU #1 (yellow)
(4) Aftertreatment #2 .DCU #2 (red)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Diesel Exhaust Fluid Control Unit (DCU) Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for 2 minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 70-pin J1 and 70-pin J2 connector from the SCR Electronic Control Module (ECM).
C. Disconnect the 53-pin connector from the affected DCU.
D. Connect the 398-5063 Probe to the DCU connector.
The probe must be used to prevent damage to the DCU connector.
E. Measure the resistance between the following pins on the affected DCU wiring harness connector:
- For Aftertreatment #1 DCU #1 measure between pin 10 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #1 measure between pin 29 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #2 measure between pin 20 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #2 measure between pin 30 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #1 measure between pin 12 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #1 measure between pin 31 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #2 measure between pin 42 on the 70-pin SCR System ECM


Parts thrust Mercruiser:

35915
 
35915 THRUST RING, BEARING CARRIER
00014332, 00019003, 01321017, 01326013, 2140208, 2165208, 2250507, 5000165CE
56292A 2
 
56292A 2 THRUST HUB AND WASHER ASSEMBLY
00014332, 00019003, 01321017, 01326013, 2140208, 2165208, 2250507, 5000165CE
835467 1
 
835467 1 THRUST HUB (FOR USE W/ BLACK MAX PROPELLERS)
00019003, 01321017, 01326013, 5000165CE, 5111200LP, 5120136JS, 5120150R1, 5231100LP, 5231100TP, 5232100N1, 5232100TP, 6020006JS, 6211001N1, 6311002NZ, 6315001N1, 6315002NZ, 6416003N2, 6511102N1, 6811001N1
815481
THRUST WASHER
815481 THRUST WASHER
00019003, 01321017, 01326013, 5000147JS, 5000150DP, 5000165CE, 5111200LP
17616
 
17616 THRUST RING
00019003, 01321017, 01326013, 5000150DP, 5000165CE
18448
 
18448 THRUST WASHER
00019003, 01321017, 01326013, 5000147JS, 5000150DP, 5000165CE, 5111200LP
815570
THRUST RACE
815570 THRUST RACE
00019003, 01321017, 01326013, 5000150DP, 5000165CE
13171
 
13171 THRUST HUB (FOR USE W/ BLACK MAX PROPELLERS)
00019003, 01321017, 01326013, 5000150DP, 5000165CE, 5120150AR, 5220200AS, 91331015
Back to top