30895 BEARING, ROLLER - FORWARD GEAR Mercury
1050302SD, 1050312LD, 1055207UD, 1070312BC, 1070717, 1075217PD, 10754120D, 1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1100312BD, 1100412PD, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 11354120D, 1135412MD, 1135412SD, 113
BEARING
Price: query
Rating:
Compatible models:
1050302SD
1050312LD
1055207UD
1070312BC
1070717
1075217PD
10754120D
1075524
1080500
1080508
1090520
1090524
1090528
1100312BD
1100412PD
1115100
1115503
1115520
1115523
1115525
1115528
1135100
11354120D
1135412MD
1135412SD
1135412VD
1135473UD
1135473VD
1140520
1140528
1140629
1150413SD
1150413VD
1150453BD
1150453GD
1150453JD
1150503
1150538
1150625
1175413MD
1200473TD
1200473UD
1200473VD
1225412PD
1225413RD
1250422GD
1650100
1800100
1850503
1850506
1F50352VD
1F50412RD
1F51452YB
Mercury
Mercury entire parts catalog list:
- GEAR HSG(PROP SHAFT)(60 SEA-MARA-BIG FOOT, 3 JAW REV. CLUTCH » 30895
- GEAR HSG(DRIVE SHAFT)(60 SEA-MARA-BIG FOOT,6 JAW REV. CLUTCH » 30895
1055207UD 1998
1070312BC 1988,1989,1990
- GEAR HOUSING(PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROP SHAFT)(6 JAW REVERSE CLUTCH) » 30895
- GEAR HOUSING (PROP SHAFT)(3 JAW REVERSE CLUTCH) » 30895
- GEAR HOUSING(PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROPELLER SHAFT) » 30895
1090520 1980,1982,1983
- GEAR HOUSING (PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROPELLER SHAFT) » 30895
1100312BD 1988,1989,1990,1991,1992,1993
- GEAR HOUSING, PROPELLER SHAFT » 30895
- GEAR HOUSING (PROP SHAFT)(6 JAW REVERSE CLUTCH) » 30895
- GEAR HOUSING (PROP SHAFT)(3 JAW REVERSE CLUTCH) » 30895
1115503 1973,1974,1976,1977
1115520 1980,1982,1983
- GEAR HOUSING (PROPELLER SHAFT) » 30895
- GEAR HOUSING (PROPELLER SHAFT) » 30895
1115528 1978,1979
1135100 1970,1971
- GEAR HOUSING ASSEMBLY, COMPLETE » 30895
1135412MD 1992,1993,1994,1995
1135412SD 1996,1997,1998
1135412VD 1999
1135473UD 1998
1135473VD 1999
1140520 1980
1140528 1978,1979
1140629 1979
1150413SD 1996,1997,1998
1150413VD 1999
1150453BD 1988
- GEAR HOUSING(PROPELLER SHAFT)(CASTING #1655-9572C) » 30895
- GEAR HOUSING(PROPELLER SHAFT) (CASTING #1674-814247C) » 30895
- GEAR HOUSING(PROPSHAFT) (CASTING # IS 1655-9572C) » 30895
- GEAR HOUSING(PROPSHAFT) (CASTING # IS 1674-814247C) » 30895
- GEAR HOUSING(PROPSHAFT) (CASTING # IS 1674-814247C) » 30895
- GEAR HOUSING(PROPSHAFT)(XR4-MAGNUM II) » 30895
- GEAR HOUSING(PROPSHAFT) (CASTING # IS 1655-9572C) » 30895
1150538 1978
1150625 1985
1175413MD 1992,1993,1994,1995
1200473TD 1997
- GEAR HSG(PROP SHAFT)STD. ROTATION(G438000 & UP) » 30895
- GEAR HSG(PROP SHAFT)STD. ROTATION(G437999 & BELOW) » 30895
1200473VD 1999
1225412PD 1994,1995,1996,1997,1998
- G.-HSG(PROP-STD-S-N-0G437999 & BELOW-1623-822442C2 » 30895
- G-HSG, PROP-STD-0G438000 AND UP-1623-822442C3 » 30895
- G-HSG, PROP-STD-0G438000 AND UP-1623-822442C3 » 30895
- G-HSG, PROP-STD-0G437999 AND BELOW-1623-822442C2 » 30895
1650100 1970,1971
1800100 1970,1971,1972
1850503 1973,1974,1975
1850506 1976,1977
- GEAR HOUSING ASSEMBLY, COMPLETE (SERIAL GROUP #2) (PAGE 2) » 30895
- GEAR HOUSING ASSEMBLY, COMPLETE (SERIAL GROUP #1) (PAGE 2) » 30895
1F50412RD 1995,1996,1997,1998
1F51452YB 2001
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
617-5 Inlet Air Heater Relay : Current Below Normal The Electronic Control Module (ECM) has detected current below normal for at least two seconds. The code is logged.
If equipped, the warning light will come on.
The ECM is unable to activate the relay for starting aid.
The starting aid will not operate.
617-6 Inlet Air Heater Relay : Current Above Normal The ECM has detected current above normal for at least two seconds.
3257-3 Air Inlet Heater : Voltage Above Normal The monitoring for the Inlet Air Heater (IAH) is enabled.
The IAH is not enabled.
The ECM has detected voltage above normal for at least 30 seconds.
The engine is running.
OR
The ECM has detected voltage above normal for at least five seconds.
The engine is not running. The code is logged.
If equipped, the warning light will come on.
The starting aid could operate all the time.
3257-4 Inlet Air Heater : Voltage Below Normal The monitoring for the IAH is enabled.
The IAH is enabled.
The ECM has detected voltage below normal for at least five seconds. The code is logged.
If equipped, the warning light will come on.
The starting aid will not operate. The starting aid is used to improve cold engine starting. The engine ECM will monitor the coolant temperature and the intake manifold air temperature in order to determine if the starting aid is required. If the starting aid is required, then the ECM will activate the starting aid relay and electrical power is switched to the starting aid for a controlled period of time. If the optional "Wait to Start Lamp" is installed then this lamp will illuminate during this period.On a cold start, a lamp output will indicate that the operator needs to "Wait to Start". Starting aids may be used during the cranking of the engine. Starting aids may be used if the engine has previously been started. The "Wait to Start" lamp will not be active in these conditions.
Illustration 1 g02805496
Typical schematic for the starting aid
Illustration 2 g01504436
A typical view of the P1 connector (wire side) pin locations.
(1) Battery−
(2) Battery−
(3) Battery−
(9) Battery−
(10) Battery−
(26) IAH return
(29) IAH control
(49) IAH monitoring
(59) Cold start lamp
Illustration 3 g01504456
A typical view of the P1 connector (ECM side) pin locations.
Illustration 4 g01325579
Typical engine ECM
(1) P2 ECM connector
(2) P1 ECM connectorTest Step 1. Check for Active Diagnostic Codes
Verify that the ECM has the latest software.Refer to Troubleshooting, "ECM Software - Install".
Turn the keyswitch to the OFF position.
Connect Caterpillar Electronic Technician (ET) to the diagnostic connector.
Turn the keyswitch to the ON position.
Use Cat ET to select the "Air Inlet Heater Override Test".
Check for active diagnostic codes or recently logged diagnostic codes.Expected Result:One of the following diagnostic codes are active or recently logged:
617-5 Inlet Air Heater Relay : Current Below Normal
617-6 Inlet Air Heater Relay : Current Above Normal
3257-3 Air Inlet Heater : Voltage Above Normal
3257-4 Air Inlet Heater : Voltage Below NormalResults:
OK - A 617-5 diagnostic code is active or recently logged. Proceed to Test step 3.
OK - A 617-6 diagnostic code is active or recently logged. Proceed to Test step 4.
OK - A 3257-3 diagnostic code is active or recently logged. Proceed to Test step 7.
OK - A 3257-4 diagnostic code is active or recently logged. Proceed to Test step 8.
Not OK - An active diagnostic code or a recently logged diagnostic code was not displayed. Proceed to Test step 11.Test Step 2. Check for Voltage to the Heater relay
Turn the keyswitch to the OFF position.
Disconnect the connector for the heater relay.
Turn the keyswitch to the ON position.
Measure the voltage between terminal 1 and terminal 2 on the harness side of the connector for the relay.Expected Result:The voltage measures approximately 0 VDC when the power for the heater relay is not activated. The voltage measures approximately 13 3 VDC when the override for the ether system is activated.Results:
OK - The voltage measurements are correct.Repair: Check the heater relay for an open or a short circuit.STOP
Not OK - One of the voltage measurements was incorrect.Repair: There is either a short or an open in the wiring between the connector for the heater relay and the ECM. Repair the wiring and/or connectors.STOPTest Step 3. Check the Relay Circuit for an Open Circuit
Turn the keyswitch to the OFF position.
Disconnect the J1/P1 ECM connector.
Check the resistance in the wire between P1-26 and test point C at the starting aid relay.
Check the resistance in the wire between P1-29 and test point D at the starting aid relay.Expected Result:The resistance measurements are within the acceptable range. There is not an open in the harness between the ECM and the solenoid relay.Results:
OK - The resistance measurements are within the acceptable range. There is not an open in the harness between the ECM and the solenoid relay. Proceed to Test Step 5.
Not OK - The resistance measurements are not within the acceptable range. There is an open in the harness and/or the connectors.Repair: Repair the connectors and/or the harness or replace the connectors and/or the harness.Return all wiring
Parts bearing Mercury:
54215
21739
21739 BEARING, ROLLER - FORWARD GEAR
1018200, 1018204, 10202014D, 1020201BC, 1020201DB, 1020201VB, 1025200, 1035204, 1035207, 1040200, 1040208, 10402139D, 1045217, 1050200, 1050302SD, 1050312BC, 1050312LD, 1055207DB, 1055207UD, 1055207VB, 1060504, 1070500, 1400100, 1402202, 1402205, 150
48410
86637
86637 BEARING
1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412FB, 1050412FD, 1150625, 1150628, 1
814103
827955A 2
827955A 2 BEARING ASSEMBLY-CENTER MAIN
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412F
817007
817007 BEARING CARRIER SEAL INSTALLER
1031203PD, 1031203UD, 1041312UB, 10432037D, 1055207UD, 1F25201UD, 1F50412RD
14308A 1