16328 BRACKET, BAFFLE PLATE Mercury
1004137, 1004201FB, 1004201JK, 1004201VB
BRACKET
Price: query
Rating:
Mercury entire parts catalog list:
- CARBURETOR » 16328
- CARBURETOR » 16328
- CARBURETOR » 16328
- CARBURETOR » 16328
Information:
7G7889 Alternator (12V 60A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 14.0 0.3VOutput (hot) ... 60A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage Setting ... No adjustmentPermissible voltage range ... 13.7 to 14.3V5N5692 Alternator (24V 45A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 42.3A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V3T6352 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 35A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V 7N9720 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 35A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5V(3) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(4) Torque for ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)100-5046 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 45A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5V(3) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(4) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in) 9G4574 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 35.6A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(3) Torque for ground terminal nut ... 4.4 1.0 N m (39 9 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V100-5045 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 44.6A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(3) Torque for ground terminal nut ... 4.4 1.0 N m (39 9 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V 112-5041 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 47A(1) Torque for the ground terminal nut ... 6.2 0.6 N m (55 5 lb in)(2) Shaft nut torque ... 102 7 N m (75 5 lb ft)(3) R Terminal is the AC tap from stator.(4) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(5) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29 4N3986 Alternator (24V 60A)
Load battery with a carbon pile (4C4911 Battery Load Tester) to get maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 54A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for terminal nuts ... 7.1 0.8 N m (63 7 lb in)(3) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5 6T1395 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 27.9AShaft nut torque ... 60 7 N m (44 5 lb ft)Torque for positive terminal nut ... 4.1 0.4 N m (36 5 lb in)Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V6T1396 Alternator (24V 51A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 13.8 0.2VOutput (hot) ... 45AShaft nut torque ... 53 to 67 N m
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 14.0 0.3VOutput (hot) ... 60A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage Setting ... No adjustmentPermissible voltage range ... 13.7 to 14.3V5N5692 Alternator (24V 45A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 42.3A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V3T6352 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 35A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 6.2 0.6 N m (55 5 lb in)(3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V 7N9720 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 35A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5V(3) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(4) Torque for ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)100-5046 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 45A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5V(3) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(4) Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in) 9G4574 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 35.6A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(3) Torque for ground terminal nut ... 4.4 1.0 N m (39 9 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V100-5045 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 44.6A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(3) Torque for ground terminal nut ... 4.4 1.0 N m (39 9 lb in)(4) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V 112-5041 Alternator (24V 50A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 47A(1) Torque for the ground terminal nut ... 6.2 0.6 N m (55 5 lb in)(2) Shaft nut torque ... 102 7 N m (75 5 lb ft)(3) R Terminal is the AC tap from stator.(4) Torque for positive terminal nut ... 13.5 1.3 N m (119 12 lb in)(5) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29 4N3986 Alternator (24V 60A)
Load battery with a carbon pile (4C4911 Battery Load Tester) to get maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 54A(1) Shaft nut torque ... 102 7 N m (75 5 lb ft)(2) Torque for terminal nuts ... 7.1 0.8 N m (63 7 lb in)(3) Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 26.5 to 28.5 6T1395 Alternator (24V 35A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1VOutput (hot) ... 27.9AShaft nut torque ... 60 7 N m (44 5 lb ft)Torque for positive terminal nut ... 4.1 0.4 N m (36 5 lb in)Torque for ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Regulator. Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V6T1396 Alternator (24V 51A)
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 13.8 0.2VOutput (hot) ... 45AShaft nut torque ... 53 to 67 N m
Parts bracket Mercury:
16239
17026
17026 BRACKET
1004137, 1004201FB, 1004201JK, 1004201VB, 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1B04201FB, 1F04201WB
17023
16338
16338 BRACKET, THROTTLE SHAFT
1004137, 1004201FB, 1004201JK, 1004201VB, 1006201FK, 1B04201FB, 1F02201HM, 1F04201WB, 1F15207DM, 1F15207FM, 1F25A17DM
16089