96367M Mercury BRUSH HOLDER


96367M BRUSH HOLDER Mercury 1F08261RF, 1F10352VD BRUSH
96367M BRUSH HOLDER Mercury
Rating:
13

Buy BRUSH HOLDER 96367M Mercury genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$179.00
 

16-08-2022

-: -
Maval 96367M - Remanufactured Power Steering Pump
Designed to deliver trouble-free, consistent performance || Right for your vehicle and lifestyle || Made from high-quality materials for ultimate durability || Manufactured to meet or exceed strict quality requirements || If you have any questions or need fitment information for your vehicle, please contact with us
$181.23
 

16-08-2022

-: -
Maval Reman 96367M Power Steering Pump
Ready to install. || No modification required.
Number on catalog scheme: 10
 

Compatible models:

Mercury entire parts catalog list:

1F08261RF 1995,1996,1997,1998
1F10352VD 1999

Information:


Table 1
Throttle 1     Throttle 2    
PWM (Digital Throttle)     Analog Throttle    
PWM (Digital Throttle)     None    
PWM (Digital Throttle)     Multi-position Throttle Switch    
Analog Throttle     Analog Throttle    
Analog Throttle     None    
Analog Throttle     Multi-position Throttle Switch    
None     Analog Throttle    
None     None    
None     Multi-position Throttle Switch    
Multi-position Throttle Switch     Analog Throttle    
Multi-position Throttle Switch     None    The throttle is set up using the electronic service tool. From the menu, select "Services". On the "Services" screen, select "Throttle Configuration". Select the type of throttle from the following list:
No throttle
Analog throttle
PWM throttle
Multi-position throttle switch
Illustration 1 g01785156
Typical Range of Throttle (1) Lower Diagnostic Limit (Default=5) (2) Lower Position Limit (Default=10) (3) Initial Lower Position (Default=20) (4) Idle Validation Minimum Off Threshold (Default=21) (5) Idle Validation Maximum On Threshold (Default=25) (6) Lower Dead Zone % (Default=8) (7) Upper Dead Zone % (Default=5) (8) Initial Upper Position (Default=70) (9) Upper Position Limit (Default=85) (10) Upper Diagnostic Limit (Default=95)PWM throttles require additional programming. If a multi-position switch is selected, additional parameters must be programmed. Refer to the Troubleshooting Guide, "Multiposition Switch Setup". If an analog throttle is selected, the following parameters must be programmed into the ECM.Idle Validation
All analog throttles on mobile applications require an idle validation switch. If this parameter is programmed to "Yes", the ECM will look for this switch input on pin J1:45 for Idle Validation Switch 1 (IVS1) and J1:44 for Idle Validation Switch 2 (IVS2).
Table 2
Values    Default    
No
Yes     Yes    Idle Validation Minimum Off (Open) Threshold
This is the minimum throttle percentage that will be detected by the ECM when the IVS is ON (Closed).If the ECM detects a throttle percentage below this value with the idle validation switch OFF (Open), a fault code will be generated and the engine will remain at idle.Refer to Table 3 and Table 4.
Table 3
Throttle Position Sensor (TPS)     Idle Validation Switch (IVS)     Throttle Demand Output     Fault Status     Comment    
TPS< IVS Min OFF     OFF     Minimum Position     Raise missing idle     Force throttle demand to minimum    
TPS< IVS Min OFF     ON     Throttle Position     Clear missing idle     Normal operation    
Table 4
Range    Default    
0 to 100%     21%    Idle Validation Maximum On (Closed) Threshold
This is the maximum throttle percentage that will be detected by the ECM when the idle validation switch (IVS) is OFF (Open) . When the idle validation switch is OFF (Open) and the ECM detects a signal that is higher than the programmed value for IVS Max ON, the ECM will generate a fault code and the engine will remain at idle.Refer to Table 5 and Table 6.
Table 5
Throttle Position Sensor (TPS)     Idle Validation Switch (IVS)     Throttle Demand Output     Fault Status     Comment    
TPS> IVS Max ON     OFF     Throttle Position     Clear unexpected idle     Normal operation    
TPS< IVS Min Off     ON     Minimum Position     Raise unexpected idle.     Force throttle demand to minimum    
Table 6
Range    Default    
0 to 100%     25%    Lower Diagnostic Limit
This is the minimum throttle percentage that should be detected by the ECM in normal operation when the pedal is in the "off" position. A value below this limit will generate a short circuit diagnostic code. The range of this diagnostic detection area is from 0 percent to the programmed value for the lower position limit.
Table 7
Range    Default    
0 to 100%     5%    Upper Diagnostic Limit
This is the minimum throttle percentage that is detected by the ECM in normal operation when the pedal is in the maximum position. A value above this limit will generate an open circuit diagnostic code. The range of this diagnostic detection area is from the programmed value of the upper position limit to 100 percent.


Parts brush Mercury:

75384
 
75384 BRUSH/SPRING KIT
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1035204, 1035207, 1040200, 10402139D, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1045217, 1050200, 1050302DB, 1050302FB, 1050302
96368M
BRUSH
96368M BRUSH
1F08261RF, 1F10352VD
96369M
BRUSH
96369M BRUSH
1F08261RF, 1F10352VD
Back to top