42698 1 Mercury CHECK VALVE


42698 1 CHECK VALVE Mercury 1006201PD, 1006201RB, 1006211RD, 1008211RD, 1016207PD, 1016207RB, 1115473WD, 1135412SD, 1135412VD, 1135473UD, 1135473VD, 1150413SD, 1150413VD, 1150413WD, 1B25211UF CHECK
42698 1 CHECK VALVE Mercury
Rating:
43

Buy CHECK VALVE 42698 1 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 4
 

Mercury entire parts catalog list:

1006201PD 1994,1995,1996,1997,1998
1006201RB 1995
1006211RD 1995
1008211RD 1995
1016207PD 1994
1016207RB 1995
1115473WD 2000
1135412SD 1996,1997,1998
1135412VD 1999
1135473UD 1998
1135473VD 1999
1150413SD 1996,1997,1998
1150413VD 1999
1150413WD 2000,2001
1B25211UF 1998

Information:


Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
When the engine-generator, or any source to which the engine-generator is synchronized to, is operating, voltages up to 600V are present in the control panel.Do not short these terminal with line voltage to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Do not connect generator to a utility electrical distribution system unless it is isolated from the system. Electrical feedback into the distribution system can occur and could cause personal injury or death.Open and secure main distribution system switch, or if the connection is permanent, install a double throw transfer switch to prevent electrical feedback. Some generators are specifically approved by a utility to run in parallel with the distribution system and isolation may not be required. Always check with your utility as to the applicable circumstances.
Illustration 1 g00837735
520 Control Module (Generator Set) (1) Indicator for oil pressure (2) Indicator for alarm (3) Indicator for coolant temperature (4) Automatic start position (5) Indicator for engine overcrank
Table 1
Symptom     Possible Remedy    
Unit does not operate     Select AUTO (4) on the control module. Check the battery and check the wiring to the unit. Check the DC power supply. Check the fuse for the DC power supply.    
Unit shuts down     The DC power supply voltage should be between 8 VDC and 35 VDC. Check that the operating temperature is below
55 °C (131 °F). Check the fuse to the DC power supply.    
Unit locks out on Emergency Stop     If an emergency stop switch is not configured, connect the emergency stop input to the positive terminal of the DC power supply. Check that the emergency stop switch is functioning correctly. Check for an open circuit.    
Intermittent sensor fault     Ensure the ground shield for the engine speed sensor is connected at one end only. If the ground shield is connected at both ends, the ground shield will act as an antenna and the ground shield will conduct random voltages.    
Indicator for oil pressure (1) operates after engine has started     Check the engine oil pressure. Check the oil pressure switch and check the wiring. Check that the configured polarity is correct.    
Indicator for coolant temperature (3) operates after engine has started     Check the engine temperature. Check the switch and check the wiring. Check the configuration of the input. The input is normally open or normally closed.    
Shutdown fault operates     Check the appropriate switch and check the wiring of the illuminated fault indicator. Check the configuration of the input. If the indicator for alarm (2) is the only indicator that is illuminated, refer to the second note in Systems Operation, "Alarm Operation".    
Warning fault operates     Check the appropriate switch and check the wiring of the illuminated fault indicator. Check the configuration of the input. If the indicator for alarm (2) is the only indicator that is illuminated, refer to the second note in Systems Operation, "Alarm Operation".    
Indicator for engine overcrank (5) activated after 3 attempts to start     Check the wiring of the fuel solenoid. Check the fuel level. Check the battery. Check that the battery signal is present on the fuel solenoid output of the module. Check that the speed sensing signal is present on the control panel inputs. Refer to Operation and Maintenance Manual, SEBU7577, "3054 and 3056 Marine Generator Set".    
Continuous starting of generator when in AUTO (4)     Check that no signal is present on the remote initiating contact. Check that the configured polarity is correct.    
Engine fails to start on receipt of remote start signal     Check that the start delay timer has expired. Check that a signal is on the remote initiating contact.    
Preheat does not operate     Check the wiring to the connectors for the engine block heater. Check the battery. Check that the battery signal is present on the preheat output of module. Check that preheat is selected in the configuration menu.    
Starting motor does not operate     Check the wiring to the starter solenoid. Check the battery. Check that the battery signal is present on the starter output of the module. Ensure that the emergency stop input is connected to the positive terminal of the DC power supply.    
Engine runs but generator will not take load     Check that the warm up timer has expired. Check the configuration in order to ensure that the output has been selected to give load transfer.    


Parts check Mercury:

42657A 1
 
42657A 1 CHECK VALVE
1004137, 1006206, 1008211RD, 1050312LD, 1070312BC, 1070717, 10754120D, 1100312BD, 1135412GD, 1135726, 1150453BD, 1150453GD, 1150453JD, 1150625, 1150628, 1175412GD, 1175626, 1200628, 1250422GD, 1300623
42698
 
42698 CHECK VALVE, BLEED HOSE
1006206, 1008211RD, 11354120D, 1135412MD, 1150453JD, 1175413LD, 1175413MD, 1200412GD, 1200413GD, 1220727
811610A 1
 
811610A 1 CHECK VALVE KIT
10754120D, 1100312BD, 1115473WD, 11354120D, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1135473UD, 1135473VD, 1135473YD, 1150413SD, 1150413VD, 1150413WD, 1150453JD, 1175413MD, 1200473TD, 1200473UD, 1200473VD, 1200473WD, 1200473YD, 1225412PD, 1225412V
42657A 3
 
42657A 3 CHECK VALVE
1004201JK, 1004201VB, 1006201AK, 1006201FK, 1006201PD, 1006201RB, 1006211RD, 1008211RD, 1015203FL, 1016207PD, 1016207RB, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031203P
821963
CHECK VALVE
821963 CHECK VALVE
1115473WD, 1135412SD, 1135412VD, 1135473UD, 1135473VD, 1150413SD, 1150413VD, 1200473TD, 1200473UD, 1200473VD, 1200473WD, 1225412PD, 1225412VD, 1225413RD, 1250413UE
858805
 
858805 CHECK VALVE (Port)
111047JHD, 1115473WD, 1135473VD, 1135473YD, 1135D73CD, 1135D73FT, 1150P73HY, 1175P73HY
855761 1
CHECK VALVE
855761 1 CHECK VALVE
111047JHD, 1115473WD, 1135473YD, 1135D73CD, 1135D73FT, 1150P73HY, 1175P73HY, 1200473WD, 1200473YD
821963 1
 
821963 1 CHECK VALVE
111047JHD, 1135412WD, 1135473YD, 1135D73CD, 1135D73FT, 1150413CD, 1150413FY, 1150413HF, 1150413HY, 1150413WD, 1150413ZD, 1150423FG, 1150423FY, 1150423HF, 1150423HG, 1150423HY, 1150424FY, 1150424HY, 1150P73HY, 1175P73HY, 1200413FY, 1200413HY, 1200423F
Back to top