892267A52 Mercury FLOAT VALVE KIT


892267A52 FLOAT VALVE KIT Mercury 1A30302ZB, 1A40302FD, 1A40302HZ, 1A40303KZ, 1A40311FZ, 1A40311HZ, 1A40403HZ, 1A40412HZ, 1A41412ZB, 1A41452EZ, 1A41452FU, 1A51411HZ, 1A51412HZ, 1A51452EZ, 1A60351EZ, 1A60412HZ, 1A60452EZ, 1A60452HZ, 1A60463EZ, 1A6C411KZ, 1A6C413KZ, 1E41412HB, 1E41452H FLOAT
892267A52 FLOAT VALVE KIT Mercury
Rating:
83

Buy FLOAT VALVE KIT 892267A52 Mercury genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$24.65
 

20-06-2023
0.0154[0.01] Pounds
-: -
FLOAT VALVE KIT
Number on catalog scheme: 24
 

Mercury entire parts catalog list:

1A30302ZB 2002,2003,2004,2005
1A40302FD 2006
1A40302HZ 2006,2010
1A40303KZ 2010
1A40311FZ 2006
1A40311HZ 2006
1A40403HZ 2006,2010
1A40412HZ 2006
1A41412ZB 2002,2003,2004,2005,2006
1A41452EZ 2006
1A41452FU 2006
1A51411HZ 2006
1A51412HZ 2006
1A51452EZ 2006
1A60351EZ 2007
1A60412HZ 2006
1A60452EZ 2006
1A60452HZ 2006
1A60463EZ 2007
1A6C411KZ 2009
1A6C413KZ 2009
1E41412HB 2006
1E41452HB 2006
1E51412HB 2006
1E51412HZ 2006
1E60403HZ 2006
1E60412HZ 2006
1E60413KZ 2009
1E60452HB 2006

Information:

Inlet Air HeaterThis feature is used to improve the cold start capability of the engine and to reduce white smoke. The ECM controls the Air Inlet Heater Grid through the Air Inlet Heater Relay.The Air Inlet Heater operation is determined at three different times; Power Up/Preheat, Cranking, and Engine Started Cycle, based on various engine parameters.A wait to start lamp is present to warn the operator the engine is cold and needs to wait until the Inlet Air Heater have heated to the correct level before cranking.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Turn the keyswitch to the ON position.
B. Connect the electronic service tool to the diagnostic connector.
C. Make a note of any active diagnostic codes.
Codes
Result: Diagnostic code 729-3 is active or logged.
Proceed to Test Step 2.
Result:Diagnostic code 729-4 is active.
Proceed to Test Step 3.
Result:A 729-5 diagnostic code is active or logged.
Proceed to test Step 4.
Result: A 729-12 diagnostic code is active or logged.
Proceed to Test Step 5.
2. Check for a Short to Battery Positive or Short to Ground
A. Turn the keyswitch to the OFF position.
B. Unplug the connector for the starter motor relay.
C. Turn the keyswitch to the ON position.
D. Use the Cat® Electronic Technician (ET) override to energize the circuit for the air inlet heater relay.
E. Observe status of active diagnostic code 729-3.
Codes
Result: Diagnostic code 729-3 remains active.
Repair: There is a short to a positive voltage in between the engine ECM and the connector for the air inlet heater relay. Repair or replace the wiring harness.
Result:Diagnostic code 729-3 is no longer active and is now logged.
Repair: The air inlet heater relay was shorted to a positive power source. Replace the air inlet heater relay.
3. Check for a Short to Ground
A. Turn the keyswitch to the OFF position.
B. Unplug the connector for the air inlet heater relay.
C. Turn the keyswitch to the ON position.
D. Use the Cat ET override to energize the circuit for the air inlet heater relay.
E. Observe status of diagnostic 729-4.
Codes
Result: Diagnostic code 729-4 is no longer active is now logged. A 729-5 diagnostic code is active.
Result: Diagnostic code 729-4 is no longer active is now logged. A 729-5 diagnostic code is active.
Result: Diagnostic code 729-4 remained active. There is a short to ground in between the connector for the air inlet heater relay and the ECM.
Repair: Repair or replace the wiring harness.
4. Check for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the air inlet heater relay.
C. Install a jumper wire to create a short circuit between terminals 1 and 2 on the connector for the air inlet heater relay.
D. Turn the keyswitch to the ON position.
E. Use the Cat ET override to energize the circuit for the inlet air heater.
F. Observe the status of the 729-5 diagnostic code.
Codes
Result: Diagnostic code 729-5 is now logged and 729-4 is now active.
Repair: Replace the air inlet heater relay.
Result: Diagnostic code 729-5 remains active with the jumper wire in place.
Repair: There is an open circuit in between the connector for the air inlet heater relay and the engine ECM. Repair or replace the wiring harness.
5. Test ECM Output
A. Turn the keyswitch to the OFF position.
B. Disconnect the air inlet heater relay connector.
C. Turn the keyswitch to the ON position.
D. Connect to Cat ET.
E. Navigate in Cat ET to "diagnostic tests", "override parameter", and select "grid heater relay" override.
F. Observe diagnostic codes.
Codes
Result: Diagnostic code 729-12 is active with the connector removed from the ECM. The relay and the override are ON.
Repair: The ECM has failed. Replace the Engine ECM. Before replacing the ECM, if possible, contact the Dealer Solution Network.
Result: Diagnostic code 729-12 did not become active with the J1/P1 connector removed. The air inlet heater relay may be shorted. Replace the air inlet heater relay. If nothing found, contact the DSN.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts float Mercury:

883221A 1
FLOAT KIT
883221A 1 FLOAT KIT
1A30302ZB, 1A41412ZB
892267527
FLOAT
892267527 FLOAT
1A30302ZB, 1A40302FD, 1A40302HZ, 1A40303KZ, 1A40311FZ, 1A40311HZ, 1A40403HZ, 1A40412HZ, 1A41412ZB, 1A41452EZ, 1A41452FU, 1A51411HZ, 1A51412HZ, 1A51452EZ, 1A60351EZ, 1A60412HZ, 1A60452EZ, 1A60452HZ, 1A60463EZ, 1A6C411KZ, 1A6C413KZ, 1E41412HB, 1E41452H
Back to top