63998A 1 SPARK GAP TESTER (SINGLE CHAMBER) Mercury
1002201FM, 1002201JK, 1002201VB, 1003201NK, 1004201FB, 1004201VB, 1006201DB, 1006201PD, 1006201RB, 1006201VB, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD, 1016207RB, 10202014D, 1020201DB, 1020201VB, 1031203PD, 1031203UB, 1031203UD, 1031207Z
SPARK
Price: query
Rating:
Compatible models:
1002201FM
1002201JK
1002201VB
1003201NK
1004201FB
1004201VB
1006201DB
1006201PD
1006201RB
1006201VB
1006211RD
1008211RD
1010207VB
1011201DB
1016207PD
1016207RB
10202014D
1020201DB
1020201VB
1031203PD
1031203UB
1031203UD
1031207ZF
1031312DB
1040213YL
1041312UB
10432037D
1043203DD
1043203VD
1043213DD
1043302DD
1043411DD
1043412DB
1043412DD
1050302DB
1050302FB
1050302FD
1050312FB
1050411DD
1050412DB
1050412DD
1050412FB
1050412FD
1055207DB
1055207UD
1055207VB
1075217DD
1075217FD
1075217PD
1075217VD
10752L7DF
10752L7FF
1075317DB
1075317FB
1075412DB
1075412DD
1075412DN
1075412FB
1075412FY
1090412DB
1090412DC
1090412DD
1090412DN
1090412DY
1090412FF
1090412FY
1090422DY
1090422FF
1090472DD
1090472FF
1090472FY
1100412PD
1100412VB
111047JHD
1115412DB
1115473WD
1135412SD
1135412VD
1135412WD
1135473UD
1135473VD
1135473YD
1135D73CD
1135D73FT
1150413CD
1150413FY
1150413HF
1150413HY
1150413SD
1150413VD
1150413WD
1150413ZD
1150423FG
1150423FY
1150423HF
1150423HG
1150423HY
1150424FY
1150424HY
1175P73HY
1200413FY
1200413HY
1200423FG
1200423FY
1200423HG
1200423HY
1200424FY
1200424HY
1200453CD
1200453EY
1200453HY
1200473UD
1200473VD
1200473WD
1200473YD
1200D73AD
1200D73CD
1200D73ET
1200D73HT
1200E73EY
1200E73HY
1225412PD
1225412VD
1225413EY
1225413RD
1225413ZD
1225423EY
1225424EY
1225E73AD
1250413CD
1250413UE
1250424EY
1250433EY
1250434EY
1256413WD
1B04201FB
1B25203ZB
1F02201HM
1F04201WB
1F08203VF
1F25201UD
1F25203VD
1F50352VD
1F50412RD
1F51452YB
Mercury
Mercury entire parts catalog list:
- TOOLS » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS-SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS-SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS-SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS - SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS(SPECIAL) » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS-SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS » 63998A 1
- TOOLS, SPECIAL » 63998A 1
- TOOLS, SPECIAL » 63998A 1
Information:
High/Low Logic Circuit
Illustration 1 g00487533
System Schematic For Spare Output
When used as a high/low logic circuit.
The spare output on the GSC is strictly used for the customer. The spare output is programmed to activate under a variety of conditions. The default is set for the output to activate when the engine is in the cooldown (SP11 = 7). The GSC treats this diagnostic code as a alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The responsibility of documenting any connections to this spare output falls on the customer and/or the dealer. Also, The responsibility of troubleshooting any connections to this spare output falls on the customer and/or the dealer. The voltage on the spare output is approximately 3.0 DCV when the spare output is not active. The voltage is approximately 3.0 DCV when there are no connections to the spare output. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground ("B-") of the signal for the spare output is present.Troubleshooting of a spare output fault is direct. The FMI defines the diagnostic code. FMI 4 is a short to ground. In order to find the exact cause of the diagnostic code, use the following information: the FMI, the system schematic for the spare output and the documentation that is provided by the dealer and/or the customerSerial Data Link
Illustration 2 g00487536
System Schematic For Spare Output
When used as a serial data link.
The GSC communicates with the relay driver module (RDM) by a serial data link. The serial data link is enabled when the setpoint SP11 is 9. For more information, see Systems Operation, "Spare Input/Output Programming OP6".Note: Earlier 103-6177 113-4500 117-6200 120-6880 123-6004 136-3870 EMCP Electronic Controls do not have the RDM serial data link capability.When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays "R2" through "R9" will maintain the current states or the relays will default to OFF. This is controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs ("R2" through "R9") will maintain the current states. If the jumper is present, "R2" through "R9" will default to OFF. Note: The maximum distance between a module and the GSC is 305 m (1000 ft). If this specification is not met, it is possible for the data link to malfunction. Also, a diagnostic code of CID 334 could occur. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC.Note: Faults are created when the harness connector (40 contact) is disconnected from the GSC during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic code is corrected. In a properly operating system, when the harness connector is removed from the GSC, the following diagnostic codes are recorded:
CID 100 FMI 2 pressure sensor (engine oil)
CID 110 FMI 2 temperature sensor (engine coolant)
CID 111 FMI 3 fluid level sensor (engine coolant)
CID 190 FMI 3 speed sensor (engine)
CID 336 FMI 2 switch (engine control)ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground of the signal for the data is present.The GSC is not able to detect an open circuit condition of the data link for the relay driver module. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the voltage of the signal for the data.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Expected Result: The voltage should change constantly. The voltage should change within the range of 0 to 10 DCV.Results:
OK - The voltage measurement is correct. Proceed to 3.
NOT OK - The voltage measurement is NOT correct. Proceed to 2.
Check the voltage of RDM and the GSC.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Voltage should be 11.6 0.5 DCV.
Measure the voltage from the contact 36 of the GSC to the ground ("B-") terminal of the relay module. The voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Expected Result: For 2c, the voltage should be 11.6 0.5 DCV. For 2d, the voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Results:
OK - Both voltage measurements are correct. Proceed to 3.
NOT OK - Voltage measured at the RDM is NOT correct. Replace the RDM. STOP.
NOT OK - Voltage measured at the GSC is NOT correct. Replace the GSC. STOP.
Check for the short in the harness.
Disconnect the harness connector from the GSC.
At the RDM, remove wire 1-PK(Pink) from terminal 4.
Measure the resistance from the wire at RDM terminal 4 to the positive battery ("B+") terminal of the relay module on the rear of the GSC.
Measure the resistance from the wire at RDM terminal 4 to ground ("B-") terminal of the relay module on the rear of the GSC. Expected Result: Both measurements should be greater than 20000 ohms. Results:
OK - Both resistance measurements are correct. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". If the diagnostic code still exists after the inspection, replace the RDM. STOP.
NOT OK - Either one or both of the resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is shorted. Troubleshoot and repair the faulty harness wiring between the RDM and the GSC. See the preceding System Schematic. STOP.
Illustration 1 g00487533
System Schematic For Spare Output
When used as a high/low logic circuit.
The spare output on the GSC is strictly used for the customer. The spare output is programmed to activate under a variety of conditions. The default is set for the output to activate when the engine is in the cooldown (SP11 = 7). The GSC treats this diagnostic code as a alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The responsibility of documenting any connections to this spare output falls on the customer and/or the dealer. Also, The responsibility of troubleshooting any connections to this spare output falls on the customer and/or the dealer. The voltage on the spare output is approximately 3.0 DCV when the spare output is not active. The voltage is approximately 3.0 DCV when there are no connections to the spare output. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground ("B-") of the signal for the spare output is present.Troubleshooting of a spare output fault is direct. The FMI defines the diagnostic code. FMI 4 is a short to ground. In order to find the exact cause of the diagnostic code, use the following information: the FMI, the system schematic for the spare output and the documentation that is provided by the dealer and/or the customerSerial Data Link
Illustration 2 g00487536
System Schematic For Spare Output
When used as a serial data link.
The GSC communicates with the relay driver module (RDM) by a serial data link. The serial data link is enabled when the setpoint SP11 is 9. For more information, see Systems Operation, "Spare Input/Output Programming OP6".Note: Earlier 103-6177 113-4500 117-6200 120-6880 123-6004 136-3870 EMCP Electronic Controls do not have the RDM serial data link capability.When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays "R2" through "R9" will maintain the current states or the relays will default to OFF. This is controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs ("R2" through "R9") will maintain the current states. If the jumper is present, "R2" through "R9" will default to OFF. Note: The maximum distance between a module and the GSC is 305 m (1000 ft). If this specification is not met, it is possible for the data link to malfunction. Also, a diagnostic code of CID 334 could occur. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC.Note: Faults are created when the harness connector (40 contact) is disconnected from the GSC during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic code is corrected. In a properly operating system, when the harness connector is removed from the GSC, the following diagnostic codes are recorded:
CID 100 FMI 2 pressure sensor (engine oil)
CID 110 FMI 2 temperature sensor (engine coolant)
CID 111 FMI 3 fluid level sensor (engine coolant)
CID 190 FMI 3 speed sensor (engine)
CID 336 FMI 2 switch (engine control)ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground of the signal for the data is present.The GSC is not able to detect an open circuit condition of the data link for the relay driver module. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the voltage of the signal for the data.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Expected Result: The voltage should change constantly. The voltage should change within the range of 0 to 10 DCV.Results:
OK - The voltage measurement is correct. Proceed to 3.
NOT OK - The voltage measurement is NOT correct. Proceed to 2.
Check the voltage of RDM and the GSC.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Voltage should be 11.6 0.5 DCV.
Measure the voltage from the contact 36 of the GSC to the ground ("B-") terminal of the relay module. The voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Expected Result: For 2c, the voltage should be 11.6 0.5 DCV. For 2d, the voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Results:
OK - Both voltage measurements are correct. Proceed to 3.
NOT OK - Voltage measured at the RDM is NOT correct. Replace the RDM. STOP.
NOT OK - Voltage measured at the GSC is NOT correct. Replace the GSC. STOP.
Check for the short in the harness.
Disconnect the harness connector from the GSC.
At the RDM, remove wire 1-PK(Pink) from terminal 4.
Measure the resistance from the wire at RDM terminal 4 to the positive battery ("B+") terminal of the relay module on the rear of the GSC.
Measure the resistance from the wire at RDM terminal 4 to ground ("B-") terminal of the relay module on the rear of the GSC. Expected Result: Both measurements should be greater than 20000 ohms. Results:
OK - Both resistance measurements are correct. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". If the diagnostic code still exists after the inspection, replace the RDM. STOP.
NOT OK - Either one or both of the resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is shorted. Troubleshoot and repair the faulty harness wiring between the RDM and the GSC. See the preceding System Schematic. STOP.
Parts spark Mercury:
97182
97182 SPARK PLUG
1005200, 1040100, 10402139D, 1045217, 1050200, 1070312BC, 1070717, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 10754120D, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1075524, 1090412DB, 1090412DC
N.S.S.
N.S.S. SPARK PLUG LEAD ASSEMBLY (27 1/2") ORDER A-36549A1 KIT FOR
1002201FM, 1002201VB, 1003201NK, 1003203, 1003209, 1004201FB, 1004201VB, 1006201AK, 1006201DB, 1006201FK, 1006201PD, 1006201RB, 1006201VB, 1006211RD, 1008201YM, 1008211RD, 1010207VB, 1011201DB, 1015203FL, 1016207PD, 1016207RB, 1016207SB, 10202014D, 1
850439T 1
850439T 1 SPARK GAP TESTER (EIGHT CHAMBER)
1002201FM, 1002201JK, 1002201VB, 1003201NK, 1004201FB, 1004201VB, 1006201DB, 1006201PD, 1006201RB, 1006201VB, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD, 1016207RB, 10202014D, 1020201DB, 1020201VB, 1031203PD, 1031203UB, 1031203UD, 1031207Z
853926
881227A05
878170
855672 1
888191