Information:


Table 1
Required Tools    
Tool    Part Number    Part Description    Qty    
A     FT-1114     Vacuum Cap     1    
5P-0306 Vacuum Transducer     1    
6V-4142 Fitting     1    
5K-5068 Fitting     1    
B     1U-9200     Lever Puller Hoist     1    
138-7574 Link Bracket     2    
189-0410 Shackle As     1    Start By:
Connect the steering frame lock.Note: Cleanliness is an important factor. Before the disassembly procedure, the exterior of the component should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the work tools have been lowered to the ground, and the oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
At operating temperature, the engine coolant is hot and under pressure.Steam can cause personal injury.Check the coolant level only after the engine has been stopped and the fill cap is cool enough to touch with your bare hand.Remove the fill cap slowly to relieve pressure.Cooling system conditioner contains alkali. Avoid contact with the skin and eyes to prevent personal injury.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Raise the hood.
Turn the battery disconnect switch to the OFF position.
Drain the cooling system coolant into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Refill Capacities".
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01175725
Install Tooling (A) onto hydraulic tank (1). Attach an air supply hose onto Tooling (A). Apply 276 to 414 kPa (40 to 60 psi) of air. This procedure will pull vacuum on the hydraulic system.
Illustration 2 g01175745
Remove tube (2) .
Illustration 3 g01175746
Disconnect hose assembly (3) .
Illustration 4 g01175747
Remove tube (4) .


Parts gasket Mercury:

9602
 
9602 GASKET KIT
1070312BC, 1070717, 1100312BD
43007 3
 
43007 3 GASKET
1070312BC, 1070717, 10754120D, 1100312BD
15172 3
 
15172 3 GASKET, Flange
1070312BC, 1075217PD, 10754120D, 1100312BD, 1100412PD
13461A90
GASKET SET
13461A90 GASKET SET
1100312BD, 1100412PD
43006 8
 
43006 8 GASKET
1075217DD, 1075217FD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412FF, 1090412FY, 1090422DY, 1090422FF, 1090472DD, 1090472F
13461A99
GASKET SET
13461A99 GASKET SET
1075217DD, 1075217FD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412FF, 1090412FY, 1090422DY, 1090422FF, 1090472DD, 1090472F
812775007
Back to top